| Literature DB >> 30988537 |
Nitin Choudhary1, Abhijit Kumar1, Amit Kohli1, Sonia Wadhawan1, Poonam Bhadoria1.
Abstract
BACKGROUND AND AIMS: I-Gel®, a novel SAD has been introduced as a ventilating device but has widely gained popularity as conduit for intubation. Unlike intubating laryngeal mask airway (ILMA), I-Gel® does not have an endotracheal tube specially designed for it. Hence the aim of this study was to compare the rate of successful intubation via I-Gel® using three different types of endotracheal tubes.Entities:
Keywords: Endotracheal tubes; I-Gel®; intubation
Year: 2019 PMID: 30988537 PMCID: PMC6423952 DOI: 10.4103/ija.IJA_615_18
Source DB: PubMed Journal: Indian J Anaesth ISSN: 0019-5049
Figure 1CONSORT diagram showing the division of patients at every stage of trial
Patient Profile
| Parameter | Group P ( | Group I ( | Group F ( | |
|---|---|---|---|---|
| Age (years) | 31.09±6.13 | 31±4.14.07 | 32.04±5.64 | 0.654 |
| Sex (M/F/) | 21/4 | 20/5 | 22/3 | 0.177 |
| Weight (kgs) | 60.7±5.3 | 58±4.2.2 | 59.6±5.1 | 0.194 |
| Height (cm) | 159.4±4.15 | 157.2±4.52 | 158.6±4.24 | 0.177 |
| ASA grade (I/II) | 22/3 | 21/4 | 19/6 | 0.101 |
| MMP (I/II) | 21/4 | 20/5 | 22/3 | 0.177 |
n – Number of patients, MMP – Modified Mallampati, M – Male, F – Female
Parameters evaluated
| Variables | Group P ( | Group I ( | Group F ( | ||
|---|---|---|---|---|---|
| 1st attempt success rate, % | 68 (17) | 48 (12) | 52 (13) | 0.041 | |
| Maneuvers used | Lateral displacement of larynx | 12 (3) | 16 (4) | 12 (3) | 0.897 |
| Downsizing of ETT | 8 (2) | 8 (2) | 12 (3) | 0.913 | |
| Overall success rate, % | 88 (22) | 72 (18) | 76 (19) | 0.037 | |
| Time taken for intubation, sec (mean±SD) | 10.51±3.82 | 13.25±5.83 | 12.79±4.91 | 0.173 | |
| Cause of failed intubation | Resistance | 3 | 2 | 2 | 0.913 |
| Oesophageal intubation | 0 | 5 | 4 | <0.001 | |
| Complications | 2 | 1 | 1 | 0.917 | |
n – Number of patients, SD – Standard deviation, sec – seconds, % – percentage
Figure 2ILMA ETT and flemometallic ETT exiting from I-Gel
Figure 4PVC ETT and flexometallic ETT exiting from I-Gel