Literature DB >> 15616092

Conventional tracheal tubes for intubation through the intubating laryngeal mask airway.

Pankaj Kundra1, N Sujata, M Ravishankar.   

Abstract

The laryngeal mask airway (LMA)-Fastrach silicone wire-reinforced tracheal tube (FTST) was specially designed for tracheal intubation through the intubating LMA (ILMA). However, conventional tracheal tubes have been successfully used to accomplish tracheal intubation. We designed this study to evaluate the success rate of blind tracheal intubation through the ILMA by using the FTST, the Rusch polyvinyl chloride tube (PVCT), and the Rusch latex armored tube (LAT). One-hundred-fifty healthy adults of ASA physical status I and II who were undergoing elective surgery under general anesthesia were randomly allocated into three groups. FTST (n=50), prewarmed PVCT (n=50), and LAT (n=50) were used for tracheal intubation. Ease of tracheal intubation was assessed by the time taken, the number of attempts, and the number of maneuvers required for success. In addition, numbers of failed intubation attempts and times taken for ILMA removal were also recorded. After surgery, the incidence of trauma, sore throat, and hoarseness was noted. Significantly more frequent success in tracheal intubation was achieved with the PVCT and FTST (96%) compared with the LAT (82%) (P <0.05). Tracheal intubation on the first attempt was similar with the PVCT and FTST (86%) and was significantly more frequent than with the LAT (52%) (P <0.05). Esophageal placement was significantly more frequent with the LAT (29.7%) when compared with the PVCT and FTST (1.8% and 7.4%, respectively) (P <0.05). The authors conclude that a prewarmed PVCT can be used as successfully as the FTST for blind tracheal intubation through the ILMA, whereas the LAT is associated with more frequent failure and esophageal intubation.

Entities:  

Mesh:

Year:  2005        PMID: 15616092     DOI: 10.1213/01.ANE.0000139348.00435.33

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  14 in total

1.  Evaluation of the Effect of Tracheal Tube Orientation on Success of Intubation through Intubating Laryngeal Mask Airway.

Authors:  Swati Chhatrapati; Anjana Sahu; Subhhash Sadashiv Auti; Swapnil Ganesh Aswar
Journal:  J Clin Diagn Res       Date:  2016-05-01

2.  Difficult intubation using intubating laryngeal mask airway in conjunction with a fiber optic bronchoscope.

Authors:  Jin-Sun Kim; Dong-Kyun Seo; Chang-Joon Lee; Hwa-Sung Jung; Seong-Su Kim
Journal:  J Dent Anesth Pain Med       Date:  2015-09-30

3.  A comparison of conventional endotracheal tube with silicone wire-reinforced tracheal tube for intubation through intubating laryngeal mask airway.

Authors:  Veena R Shah; Guruprasad P Bhosale; Tanu Mehta; Geeta P Parikh
Journal:  Saudi J Anaesth       Date:  2014-04

4.  Submental intubation with intubating laryngeal mask airway as conduit: An airway option for oral submucous fibrosis release.

Authors:  Aruloli Mohambourame; Mohamed Sameer; V R Hemanth Kumar; Muthukumaran Ramamirtham
Journal:  Anesth Essays Res       Date:  2015 Jan-Apr

5.  Intubation Success through I-Gel® and Intubating Laryngeal Mask Airway® Using Flexible Silicone Tubes: A Randomised Noninferiority Trial.

Authors:  Latha Naik; Neerja Bhardwaj; Indu Mohini Sen; Rakesh V Sondekoppam
Journal:  Anesthesiol Res Pract       Date:  2016-07-10

6.  Supraglottic airway devices as a strategy for unassisted tracheal intubation: A network meta-analysis.

Authors:  EunJin Ahn; GeunJoo Choi; Hyun Kang; ChongWha Baek; YongHun Jung; YoungCheol Woo; SiRa Bang
Journal:  PLoS One       Date:  2018-11-05       Impact factor: 3.240

7.  Endotracheal intubation through the intubating laryngeal mask airway (LMA-Fastrach™): A randomized study of LMA- Fastrach™ wire-reinforced silicone endotracheal tube versus conventional polyvinyl chloride tracheal tube.

Authors:  Megha U Sharma; Satinder Gombar; Kanti K Gombar; Baljit Singh; Nidhi Bhatia
Journal:  Indian J Anaesth       Date:  2013-01

8.  Comparison of supraglottic devices i-gel(®) and LMA Fastrach(®) as conduit for endotracheal intubation.

Authors:  Sameer Kapoor; Dharam Das Jethava; Priyamvada Gupta; Durga Jethava; Alok Kumar
Journal:  Indian J Anaesth       Date:  2014-07

9.  Tracheal intubation through laryngeal mask airway CTrach™ with polyvinyl chloride tube: Comparison between two orientations of the tracheal tube.

Authors:  Karri Pavani; Handattu Mahabaleswara Krishna; Joseph Nandhini
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2017 Oct-Dec

10.  A cohort evaluation of clinical use and performance characteristics of Ambu® AuraGain™: A prospective observational study.

Authors:  Devangi A Parikh; Ruchi A Jain; Smita S Lele; Bharati A Tendolkar
Journal:  Indian J Anaesth       Date:  2017-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.