Literature DB >> 22075016

Tracheal intubation through the I-gel™ supraglottic airway versus the LMA Fastrach™: a randomized controlled trial.

Antoine Elie Halwagi1, Nathalie Massicotte, Alexandre Lallo, Alain Gauthier, Daniel Boudreault, Monique Ruel, François Girard.   

Abstract

BACKGROUND: The i-gel™ is a supraglottic airway device not requiring inflation of a cuff for lung ventilation. Its design allows for unobstructed passage of a tracheal tube and previous studies have demonstrated a favorable alignment with the glottic inlet. In this prospective randomized study, we compared the success rate of blind tracheal intubation using the i-gel and the laryngeal mask airway (LMA) Fastrach™.
METHODS: One hundred sixty patients requiring general anesthesia and airway management were randomized to tracheal intubation using the i-gel or the LMA Fastrach. After induction of general anesthesia, the allocated device was inserted and adequate lung ventilation was confirmed. Blind tracheal intubation was then attempted. First attempt and overall tracheal intubation success rates were evaluated and tracheal intubation times were measured.
RESULTS: Eighty patients were recruited in each study group. Successful tracheal intubation was obtained on the first attempt in 69% of patients with the i-gel and 74% of patients with the LMA Fastrach (95% confidence interval [CI] of difference, -9% to 19%, P = 0.60). The overall intubation success rate was lower using the i-gel than it was using the LMA Fastrach (73% vs 91%, 95% CI of difference, 7% to 31%, P < 0.0001).
CONCLUSIONS: On first attempts, successful blind tracheal intubation was obtained at comparable rates using the i-gel and the LMA Fastrach. However, when the first attempt was unsuccessful, subsequent attempts through the i-gel did not significantly increase tracheal intubation success rate. The LMA Fastrach yielded a higher overall intubation success rate.

Entities:  

Mesh:

Year:  2011        PMID: 22075016     DOI: 10.1213/ANE.0b013e318236f438

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  17 in total

1.  Comparative evaluation of Intubating Laryngeal Mask Airway (ILMA), I-gel and Ambu AuraGain for blind tracheal intubation in adults.

Authors:  Riniki Sarma; Rakesh Kumar; Neera Gupta Kumar; Munisha Agarwal; Manoj Bhardwaj; Saud Ahmed Ansari; G P Deepak
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2021-09-21

2.  To assess the efficacy of i-gel for ventilation, blind tracheal intubation and nasogastric tube insertion.

Authors:  Geeta Bhandari; K S Shahi; Mohd Asad; Nitish Kumar Parmar; Rajni Bhakuni
Journal:  Anesth Essays Res       Date:  2013 Jan-Apr

3.  Nasopharyngeal airway as an aid to remove i-gel™ after endotracheal intubation through the device.

Authors:  Indu Sen; Neeraj Bhardwaj; Ys Latha
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2014-10

4.  Comparison of the Disposable Streamlined Liner of the Pharynx Airway and the Disposable I-gel in Anaesthetized, Paralyzed Adults: A Randomized Prospective Study.

Authors:  Khaled El-Radaideh; Ala A Alhowary; Diab Bani Hani
Journal:  Anesthesiol Res Pract       Date:  2015-12-01

5.  Intubation Success through I-Gel® and Intubating Laryngeal Mask Airway® Using Flexible Silicone Tubes: A Randomised Noninferiority Trial.

Authors:  Latha Naik; Neerja Bhardwaj; Indu Mohini Sen; Rakesh V Sondekoppam
Journal:  Anesthesiol Res Pract       Date:  2016-07-10

6.  All India Difficult Airway Association 2016 guidelines for the management of unanticipated difficult tracheal intubation in adults.

Authors:  Sheila Nainan Myatra; Amit Shah; Pankaj Kundra; Apeksh Patwa; Venkateswaran Ramkumar; Jigeeshu Vasishtha Divatia; Ubaradka S Raveendra; Sumalatha Radhakrishna Shetty; Syed Moied Ahmed; Jeson Rajan Doctor; Dilip K Pawar; Singaravelu Ramesh; Sabyasachi Das; Rakesh Garg
Journal:  Indian J Anaesth       Date:  2016-12

7.  Utility of the Aintree Intubation Catheter in fiberoptic tracheal intubation through the three types of intubating supraglottic airways: a manikin simulation study.

Authors:  Ryusuke Ueki; Nobuyasu Komasawa; Kenta Nishimoto; Takashi Sugi; Munetaka Hirose; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2013-10-17       Impact factor: 2.078

8.  Comparison of supraglottic devices i-gel(®) and LMA Fastrach(®) as conduit for endotracheal intubation.

Authors:  Sameer Kapoor; Dharam Das Jethava; Priyamvada Gupta; Durga Jethava; Alok Kumar
Journal:  Indian J Anaesth       Date:  2014-07

9.  Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults.

Authors:  C Frerk; V S Mitchell; A F McNarry; C Mendonca; R Bhagrath; A Patel; E P O'Sullivan; N M Woodall; I Ahmad
Journal:  Br J Anaesth       Date:  2015-11-10       Impact factor: 9.166

10.  Comparison of blind intubation through supraglottic devices and direct laryngoscopy by novices: a simulation manikin study.

Authors:  Young Yong Kim; Gu Hyun Kang; Won Hee Kim; Hyun Young Choi; Yong Soo Jang; Young Jae Lee; Jae Guk Kim; Hyeongtae Kim; Gyoung Yong Kim
Journal:  Clin Exp Emerg Med       Date:  2016-06-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.