Literature DB >> 30978713

Dual-ended readout of bismuth germanate to improve timing resolution in time-of-flight PET.

Sun Il Kwon1, Emilie Roncali, Alberto Gola, Giovanni Paternoster, Claudio Piemonte, Simon R Cherry.   

Abstract

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 30978713      PMCID: PMC7323734          DOI: 10.1088/1361-6560/ab18da

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


× No keyword cloud information.
  18 in total

Review 1.  From PET detectors to PET scanners.

Authors:  John L Humm; Anatoly Rosenfeld; Alberto Del Guerra
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-10-02       Impact factor: 9.236

2.  Optical, thermo-optic, electro-optic, and photoelastic properties of bismuth germanate (Bi(4)Ge(3)O(12)).

Authors:  P A Williams; A H Rose; K S Lee; D C Conrad; G W Day; P D Hale
Journal:  Appl Opt       Date:  1996-07-01       Impact factor: 1.980

3.  Recent Advances and Future Advances in Time-of-Flight PET.

Authors:  William W Moses
Journal:  Nucl Instrum Methods Phys Res A       Date:  2007-10-01       Impact factor: 1.455

4.  CHERENCUBE: concept definition and implementation challenges of a Cherenkov-based detector block for PET.

Authors:  I Somlai-Schweiger; S I Ziegler
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

5.  Advanced optical simulation of scintillation detectors in GATE V8.0: first implementation of a reflectance model based on measured data.

Authors:  Mariele Stockhoff; Sebastien Jan; Albertine Dubois; Simon R Cherry; Emilie Roncali
Journal:  Phys Med Biol       Date:  2017-04-28       Impact factor: 3.609

6.  High-frequency SiPM readout advances measured coincidence time resolution limits in TOF-PET.

Authors:  Stefan Gundacker; Rosana Martinez Turtos; Etiennette Auffray; Marco Paganoni; Paul Lecoq
Journal:  Phys Med Biol       Date:  2019-02-27       Impact factor: 3.609

Review 7.  Update on time-of-flight PET imaging.

Authors:  Suleman Surti
Journal:  J Nucl Med       Date:  2014-12-18       Impact factor: 10.057

8.  Improved single photon time resolution for analog SiPMs with front end readout that reduces influence of electronic noise.

Authors:  Joshua W Cates; Stefan Gundacker; Etiennette Auffray; Paul Lecoq; Craig S Levin
Journal:  Phys Med Biol       Date:  2018-09-19       Impact factor: 3.609

9.  Advances in coincidence time resolution for PET.

Authors:  Joshua W Cates; Craig S Levin
Journal:  Phys Med Biol       Date:  2016-02-25       Impact factor: 3.609

10.  Monte Carlo calculations of PET coincidence timing: single and double-ended readout.

Authors:  Stephen E Derenzo; Woon-Seng Choong; William W Moses
Journal:  Phys Med Biol       Date:  2015-09-09       Impact factor: 3.609

View more
  4 in total

Review 1.  Update on latest advances in time-of-flight PET.

Authors:  Suleman Surti; Joel S Karp
Journal:  Phys Med       Date:  2020-11-16       Impact factor: 2.685

2.  Study of Čerenkov Light Emission in the Semiconductors TlBr and TlCl for TOF-PET.

Authors:  Gerard Ariño-Estrada; Emilie Roncali; Aaron R Selfridge; Junwei Du; Jaroslaw Glodo; Kanai S Shah; Simon R Cherry
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-09-17

Review 3.  Silicon photomultiplier signal readout and multiplexing techniques for positron emission tomography: a review.

Authors:  Haewook Park; Minseok Yi; Jae Sung Lee
Journal:  Biomed Eng Lett       Date:  2022-07-16

4.  A digital phoswich detector using time-over-threshold for depth of interaction in PET.

Authors:  David L Prout; Zheng Gu; Max Shustef; Arion F Chatziioannou
Journal:  Phys Med Biol       Date:  2020-12-15       Impact factor: 3.609

  4 in total