Literature DB >> 30936945

The fulcrum axis: an accurate measure of glenoid version on radiographs and computed tomography.

Jennifer Mutch1, Martin Sidler2, Claudia Sidler-Maier3, Terry Axelrod3, Diane Nam3.   

Abstract

BACKGROUND: Proper glenoid position in total shoulder arthroplasty (TSA) is important. However, traditional glenoid version (GV) measurements overestimate retroversion on radiographs (XR) and computed tomography (CT).The fulcrum axis (FA) uses palpable surface landmarks and may be useful as an intra-operative guide. Also, the FA has not yet been validated on XR or CT in an arthritic population.
METHODS: Four observers measured FA and GV on the XR, CT and three-dimensional CT (3DCT) of 40 patients who underwent TSA at a single institution from 2009 to 2015. Reliability and accuracy of FA and GV were calculated for XR and CT, using 3DCT as the gold standard.
RESULTS: The mean FA and GV were 7.768° and 18.910° on XR; 6.23° and 12.920° on CT; and 8.100° and 7.740° on 3DCT, respectively. FA and GV were significantly different for XR and CT (p < 0.001) but not for 3DCT (p = 0.725). The inter-rater reliability, intra-rater reliability and accuracy of FA were not significantly different from GV and were 0.929 to 0.948, 0.779 to 0.974 and 0.674 to 0.705, respectively. However, the absolute difference of FA was closer to the gold standard (3DCT) than GV for XR (0.330° versus 11.172°) and CT (1.871° versus 5.178°) (p < 0.001).
CONCLUSIONS: FA showed comparable reliability and accuracy to GV. However, FA more accurately reflected the gold standard.

Entities:  

Keywords:  accuracy; fulcrum axis; glenoid version; osteoarthritis; reliability; shoulder

Year:  2017        PMID: 30936945      PMCID: PMC6434962          DOI: 10.1177/1758573217728291

Source DB:  PubMed          Journal:  Shoulder Elbow        ISSN: 1758-5732


  31 in total

1.  Variability of measurement of glenoid version on computed tomography scan.

Authors:  D J Bokor; M D O'Sullivan; G J Hazan
Journal:  J Shoulder Elbow Surg       Date:  1999 Nov-Dec       Impact factor: 3.019

2.  Measurement of glenoid version: conventional radiographs versus computed tomography scans.

Authors:  Richard W Nyffeler; Bernhard Jost; Christian W A Pfirrmann; Christian Gerber
Journal:  J Shoulder Elbow Surg       Date:  2003 Sep-Oct       Impact factor: 3.019

3.  The use of computerized tomography in the measurement of glenoid version.

Authors:  R J Friedman; K B Hawthorne; B M Genez
Journal:  J Bone Joint Surg Am       Date:  1992-08       Impact factor: 5.284

4.  Biomechanical effects of glenoid retroversion in total shoulder arthroplasty.

Authors:  Todd A Shapiro; Michelle H McGarry; Ranjan Gupta; Yeon Soo Lee; Thay Q Lee
Journal:  J Shoulder Elbow Surg       Date:  2006-12-12       Impact factor: 3.019

5.  Effects of glenoid component version on humeral head displacement and joint reaction forces: an experimental study.

Authors:  Richard W Nyffeler; Ralph Sheikh; Todd S Atkinson; Hilaire A C Jacob; Philippe Favre; Christian Gerber
Journal:  J Shoulder Elbow Surg       Date:  2006 Sep-Oct       Impact factor: 3.019

6.  Risks of loosening of a prosthetic glenoid implanted in retroversion.

Authors:  Alain Farron; Alexandre Terrier; Philippe Büchler
Journal:  J Shoulder Elbow Surg       Date:  2006 Jul-Aug       Impact factor: 3.019

7.  Humeral head replacement for the treatment of osteoarthritis.

Authors:  Damian M Rispoli; John W Sperling; George S Athwal; Cathy D Schleck; Robert H Cofield
Journal:  J Bone Joint Surg Am       Date:  2006-12       Impact factor: 5.284

8.  Morphologic study of the glenoid in primary glenohumeral osteoarthritis.

Authors:  G Walch; R Badet; A Boulahia; A Khoury
Journal:  J Arthroplasty       Date:  1999-09       Impact factor: 4.757

9.  The effects of glenoid component alignment variations on cement mantle stresses in total shoulder arthroplasty.

Authors:  Andrew R Hopkins; Ulrich N Hansen; Andrew A Amis; Roger Emery
Journal:  J Shoulder Elbow Surg       Date:  2004 Nov-Dec       Impact factor: 3.019

10.  Glenoid wear after shoulder hemiarthroplasty: quantitative radiographic analysis.

Authors:  I M Parsons; Peter J Millett; Jon J P Warner
Journal:  Clin Orthop Relat Res       Date:  2004-04       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.