Literature DB >> 17169588

Biomechanical effects of glenoid retroversion in total shoulder arthroplasty.

Todd A Shapiro1, Michelle H McGarry, Ranjan Gupta, Yeon Soo Lee, Thay Q Lee.   

Abstract

The purpose of this study was to evaluate the effects of glenoid retroversion after total shoulder arthroplasty on glenohumeral joint contact pressures, contact areas, and forces. We studied 8 cadaveric shoulders with a custom shoulder testing system that permits anatomic loading of the rotator cuff and the humerothoracic muscles. Each shoulder was tested intact and after total shoulder arthroplasty with the glenoid component in a neutral position and with the glenoid component retroverted 15 degrees . Glenohumeral contact pressures and areas were measured with Fuji pressure-sensitive film, and the glenohumeral forces were measured with a 6-df load cell. Glenohumeral contact areas decreased significantly, and contact pressures increased after total shoulder arthroplasty with both neutral glenoid components and retroverted glenoid components (P < .0002 to .04). Inferior forces decreased significantly after total shoulder arthroplasty with the retroverted glenoid components when compared with the intact, native shoulder (P < .02). Posterior forces also decreased significantly with the retroverted glenoid when compared with the neutral glenoid (P < .03). Placement of the glenoid in 15 degrees of retroversion significantly decreased glenohumeral contact area, increased contact pressure, and decreased inferior and posterior glenohumeral forces. Glenoid component retroversion may result in eccentric loading of the glenoid component and possibly lead to wear and loosening, signifying the importance of correct anatomic placement during total shoulder arthroplasty.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17169588     DOI: 10.1016/j.jse.2006.07.010

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  46 in total

1.  CORR Insights(®): posterior glenoid wear in total shoulder arthroplasty: eccentric anterior reaming is superior to posterior augment.

Authors:  Sergio Gutiérrez
Journal:  Clin Orthop Relat Res       Date:  2015-09-22       Impact factor: 4.176

2.  Axillary view: arthritic glenohumeral anatomy and changes after ream and run.

Authors:  Frederick A Matsen; Akash Gupta
Journal:  Clin Orthop Relat Res       Date:  2013-10-18       Impact factor: 4.176

3.  Morphological analysis of the glenoid version in the axial plane according to age.

Authors:  Julia Bouchaib; Philippe Clavert; Jean-François Kempf; Jean-Luc Kahn
Journal:  Surg Radiol Anat       Date:  2013-11-30       Impact factor: 1.246

4.  Description and reproducibility assessment of a new computerised tomography scan index to measure the glenoid orientation in relation to the anterior glenoid surface.

Authors:  Constantina Moraiti; Shahnaz Klouche; Jean David Werthel; Thomas Bauer; Philippe Hardy
Journal:  Int Orthop       Date:  2016-10-04       Impact factor: 3.075

5.  Stability of two versus three peripheral pegs of the glenoid component in modern total shoulder arthroplasty.

Authors:  Eugene F Stautberg; Daniel C Jupiter; Arsalan Amin; Ali A Qadeer; Omer A Ilahi
Journal:  Int Orthop       Date:  2017-08-24       Impact factor: 3.075

6.  Does Postoperative Glenoid Retroversion Affect the 2-Year Clinical and Radiographic Outcomes for Total Shoulder Arthroplasty?

Authors:  Benjamin C Service; Jason E Hsu; Jeremy S Somerson; Stacy M Russ; Frederick A Matsen
Journal:  Clin Orthop Relat Res       Date:  2017-07-05       Impact factor: 4.176

7.  Glenoid bone loss in primary and revision shoulder arthroplasty.

Authors:  Amar Malhas; Abbas Rashid; Dave Copas; Steve Bale; Ian Trail
Journal:  Shoulder Elbow       Date:  2016-05-06

8.  Can the ream and run procedure improve glenohumeral relationships and function for shoulders with the arthritic triad?

Authors:  Frederick A Matsen; Winston J Warme; Sarah E Jackins
Journal:  Clin Orthop Relat Res       Date:  2014-12-09       Impact factor: 4.176

9.  Planning software and patient-specific instruments in shoulder arthroplasty.

Authors:  James D Wylie; Robert Z Tashjian
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

10.  Posterior glenoid wear in total shoulder arthroplasty: eccentric anterior reaming is superior to posterior augment.

Authors:  Tim Wang; Geoffrey D Abrams; Anthony W Behn; Derek Lindsey; Nicholas Giori; Emilie V Cheung
Journal:  Clin Orthop Relat Res       Date:  2015-08-05       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.