Literature DB >> 11283987

Neuroimaging at 1.5 T and 3.0 T: comparison of oxygenation-sensitive magnetic resonance imaging.

G Krüger1, A Kastrup, G H Glover.   

Abstract

Noise properties, the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and signal responses were compared during functional activation of the human brain at 1.5 and 3.0 T. At the higher field spiral gradient-echo (GRE) brain images revealed an average gain in SNR of 1.7 in fully relaxed and 2.2 in images with a repetition time (TR) of 1.5 sec. The tempered gain at longer TRs reflects the fact that the physiological noise depends on the signal strength and becomes a larger fraction of the total noise at 3.0 T. Activation of the primary motor and visual cortex resulted in a 36% and 44% increase of "activated pixels" at 3.0 T, which reflects a greater sensitivity for the detection of activated gray matter at the higher field. The gain in the CNR exhibited a dependency on the underlying tissue, i.e., an increase of 1.8x in regions of particular high activation-induced signal changes (presumably venous vessels) and of 2.2x in the average activated areas. These results demonstrate that 3.0 T provides a clear advantage over 1.5 T for neuroimaging of homogeneous brain tissue, although stronger physiological noise contributions, more complicated signal features in the proximity of strong susceptibility gradients, and changes in the intrinsic relaxation times may mediate the enhancement. Magn Reson Med 45:595-604, 2001. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11283987     DOI: 10.1002/mrm.1081

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  109 in total

Review 1.  [Clinical MR at 3 Tesla: current status].

Authors:  K T Baudendistel; J T Heverhagen; M V Knopp
Journal:  Radiologe       Date:  2004-01       Impact factor: 0.635

2.  Distinct neural substrates for semantic knowledge and naming in the temporoparietal network.

Authors:  Benno Gesierich; Jorge Jovicich; Marianna Riello; Michela Adriani; Alessia Monti; Valentina Brentari; Simon D Robinson; Stephen M Wilson; Scott L Fairhall; Maria Luisa Gorno-Tempini
Journal:  Cereb Cortex       Date:  2011-11-02       Impact factor: 5.357

3.  Physiological noise effects on the flip angle selection in BOLD fMRI.

Authors:  J Gonzalez-Castillo; V Roopchansingh; P A Bandettini; J Bodurka
Journal:  Neuroimage       Date:  2010-11-10       Impact factor: 6.556

4.  Effects of combining field strengths on auditory functional MRI group analysis: 1.5T and 3T.

Authors:  Kihwan Han; Thomas M Talavage
Journal:  J Magn Reson Imaging       Date:  2011-09-29       Impact factor: 4.813

5.  Three-dimensional acquisition of cerebral blood volume and flow responses during functional stimulation in a single scan.

Authors:  Ying Cheng; Peter C M van Zijl; James J Pekar; Jun Hua
Journal:  Neuroimage       Date:  2014-08-23       Impact factor: 6.556

Review 6.  [Methodological principles for optimising functional MR experiments].

Authors:  T Wüstenberg; F L Giesel; H Strasburger
Journal:  Radiologe       Date:  2005-02       Impact factor: 0.635

7.  MR vascular fingerprinting: A new approach to compute cerebral blood volume, mean vessel radius, and oxygenation maps in the human brain.

Authors:  T Christen; N A Pannetier; W W Ni; D Qiu; M E Moseley; N Schuff; G Zaharchuk
Journal:  Neuroimage       Date:  2013-12-07       Impact factor: 6.556

Review 8.  Functional magnetic resonance imaging in pediatrics.

Authors:  M Wilke; S K Holland; J S Myseros; V J Schmithorst; W S Ball
Journal:  Neuropediatrics       Date:  2003-06       Impact factor: 1.947

9.  Improving the use of principal component analysis to reduce physiological noise and motion artifacts to increase the sensitivity of task-based fMRI.

Authors:  David A Soltysik; David Thomasson; Sunder Rajan; Nadia Biassou
Journal:  J Neurosci Methods       Date:  2014-12-04       Impact factor: 2.390

10.  Human brain functional MRI and DTI visualization with virtual reality.

Authors:  Bin Chen; John Moreland; Jingyu Zhang
Journal:  Quant Imaging Med Surg       Date:  2011-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.