Literature DB >> 18710991

Simultaneous MR/PET imaging of the human brain: feasibility study.

Heinz-Peter W Schlemmer1, Bernd J Pichler, Matthias Schmand, Ziad Burbar, Christian Michel, Ralf Ladebeck, Kirstin Jattke, David Townsend, Claude Nahmias, Pradeep K Jacob, Wolf-Dieter Heiss, Claus D Claussen.   

Abstract

The purpose of this study was to apply a magnetic resonance (MR) imaging-compatible positron emission tomographic (PET) detector technology for simultaneous MR/PET imaging of the human brain and skull base. The PET detector ring consists of lutetium oxyorthosilicate (LSO) scintillation crystals in combination with avalanche photodiodes (APDs) mounted in a clinical 3-T MR imager with use of the birdcage transmit/receive head coil. Following phantom studies, two patients were simultaneously examined by using fluorine 18 fluorodeoxyglucose (FDG) PET and MR imaging and spectroscopy. MR/PET data enabled accurate coregistration of morphologic and multifunctional information. Simultaneous MR/PET imaging is feasible in humans, opening up new possibilities for the emerging field of molecular imaging. RSNA, 2008

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18710991     DOI: 10.1148/radiol.2483071927

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  123 in total

1.  Small-animal molecular imaging methods.

Authors:  Robert A de Kemp; Frederick H Epstein; Ciprian Catana; Benjamin M W Tsui; Erik L Ritman
Journal:  J Nucl Med       Date:  2010-05-01       Impact factor: 10.057

Review 2.  Targeted probes for cardiovascular MRI.

Authors:  Ritika Uppal; Peter Caravan
Journal:  Future Med Chem       Date:  2010-03       Impact factor: 3.808

Review 3.  Molecular brain imaging in the multimodality era.

Authors:  Julie C Price
Journal:  J Cereb Blood Flow Metab       Date:  2012-03-21       Impact factor: 6.200

4.  Evaluation of a 3D local multiresolution algorithm for the correction of partial volume effects in positron emission tomography.

Authors:  Adrien Le Pogam; Mathieu Hatt; Patrice Descourt; Nicolas Boussion; Charalampos Tsoumpas; Federico E Turkheimer; Caroline Prunier-Aesch; Jean-Louis Baulieu; Denis Guilloteau; Dimitris Visvikis
Journal:  Med Phys       Date:  2011-09       Impact factor: 4.071

5.  Assessment of MR compatibility of a PET insert developed for simultaneous multiparametric PET/MR imaging on an animal system operating at 7 T.

Authors:  Hans F Wehrl; Martin S Judenhofer; Axel Thielscher; Petros Martirosian; Fritz Schick; Bernd J Pichler
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

Review 6.  Preclinical lymphatic imaging.

Authors:  Fan Zhang; Gang Niu; Guangming Lu; Xiaoyuan Chen
Journal:  Mol Imaging Biol       Date:  2011-08       Impact factor: 3.488

7.  Multimodal imaging utilising integrated MR-PET for human brain tumour assessment.

Authors:  Irene Neuner; Joachim B Kaffanke; Karl-Josef Langen; Elena Rota Kops; Lutz Tellmann; Gabriele Stoffels; Christoph Weirich; Christian Filss; Jürgen Scheins; Hans Herzog; N Jon Shah
Journal:  Eur Radiol       Date:  2012-07-11       Impact factor: 5.315

8.  Fibrin-targeted PET probes for the detection of thrombi.

Authors:  Katie L Ciesienski; Yan Yang; Ilknur Ay; Daniel B Chonde; Galen S Loving; Tyson A Rietz; Ciprian Catana; Peter Caravan
Journal:  Mol Pharm       Date:  2013-01-30       Impact factor: 4.939

Review 9.  Positron emission tomography-magnetic resonance imaging: technical review.

Authors:  Raymond F Muzic; Frank P DiFilippo
Journal:  Semin Roentgenol       Date:  2014-10-18       Impact factor: 0.800

10.  On the accuracy and reproducibility of a novel probabilistic atlas-based generation for calculation of head attenuation maps on integrated PET/MR scanners.

Authors:  Kevin T Chen; David Izquierdo-Garcia; Clare B Poynton; Daniel B Chonde; Ciprian Catana
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-08-29       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.