OBJECTIVES: To evaluate the influence of cone beam CT (CBCT) volume orientation on alveolar bone measurements for dental implant planning using CBCT in patients with different facial profiles.
METHODS: 74 CBCT volumes were selected from a database and classified according to the facial profile of the patient. Height and width measurements of the alveolar bone were carried out with the volume of the mandible in two different orientations: occlusal plane and mandibular base parallel to the horizontal plane. The data were subjected to the mixed model methodology for repeated measures, through the PROC MIXED procedure. Multiple comparisons were performed by Tukey Kramer test (α = 0.05).
RESULTS: Alveolar bone width was significantly greater when the CBCT volume was oriented with the mandibular base parallel to the horizontal plane, for all facial profiles (p ≤ 0.05). Alveolar bone height was significantly higher (p ≤ 0.05) for dolichofacial individuals when compared to that of mesofacial and brachyfacial individuals, who did not differ significantly between each other (p > 0.05), regardless of the CBCT volume orientations used in this study.
CONCLUSIONS: CBCT-based alveolar bone width is increased when the image volume is oriented with the mandibular base parallel to the horizontal plane and dolichofacial individuals present greater alveolar bone height.

Entities:  

Keywords:  cone-beam CT; dental implants; mandible; patient positioning.

Mesh:

Substances:

Year:  2019        PMID: 30864821      PMCID: PMC6747440          DOI: 10.1259/dmfr.20180330

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  22 in total

1.  An analysis of different approaches to the assessment of upper airway morphology: a CBCT study.

Authors:  M G Lenza; M M de O Lenza; M Dalstra; B Melsen; P M Cattaneo
Journal:  Orthod Craniofac Res       Date:  2010-05       Impact factor: 1.826

2.  3D-CT evaluation of facial asymmetry.

Authors:  Akitoshi Katsumata; Masami Fujishita; Masahito Maeda; Yoshiko Ariji; Eiichiro Ariji; Robert P Langlais
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2005-02

Review 3.  Imaging technology in implant diagnosis.

Authors:  Christos Angelopoulos; Tara Aghaloo
Journal:  Dent Clin North Am       Date:  2011-01

4.  Comparison of cone beam computed tomography imaging with physical measures.

Authors:  S A Stratemann; J C Huang; K Maki; A J Miller; D C Hatcher
Journal:  Dentomaxillofac Radiol       Date:  2008-02       Impact factor: 2.419

Review 5.  Alveolar bone dimensional changes of post-extraction sockets in humans: a systematic review.

Authors:  Fridus Van der Weijden; Federico Dell'Acqua; Dagmar Else Slot
Journal:  J Clin Periodontol       Date:  2009-12       Impact factor: 8.728

Review 6.  Artefacts in CBCT: a review.

Authors:  R Schulze; U Heil; D Gross; D D Bruellmann; E Dranischnikow; U Schwanecke; E Schoemer
Journal:  Dentomaxillofac Radiol       Date:  2011-07       Impact factor: 2.419

7.  Accuracy and reliability of cone-beam computed tomography measurements: Influence of head orientation.

Authors:  Amr Ragab El-Beialy; Mona Salah Fayed; Ahmed Mohammed El-Bialy; Yehya A Mostafa
Journal:  Am J Orthod Dentofacial Orthop       Date:  2011-08       Impact factor: 2.650

8.  Computed tomography for dental implants: the influence of the gantry angle and mandibular positioning on the bone height and width.

Authors:  J A Dantas; A Montebello Filho; P S F Campos
Journal:  Dentomaxillofac Radiol       Date:  2005-01       Impact factor: 2.419

9.  Accuracy of three-dimensional measurements obtained from cone beam computed tomography surface-rendered images for cephalometric analysis: influence of patient scanning position.

Authors:  Bassam Hassan; Paul van der Stelt; Gerard Sanderink
Journal:  Eur J Orthod       Date:  2008-12-23       Impact factor: 3.075

10.  A comparison of two-dimensional radiography and three-dimensional computed tomography in angular cephalometric measurements.

Authors:  R Nalçaci; F Oztürk; O Sökücü
Journal:  Dentomaxillofac Radiol       Date:  2010-02       Impact factor: 2.419

View more
  3 in total

1.  Evaluation of the clinical efficacy and safety of modified alveolar cleft bone graft with cone-beam CT digital imaging in children.

Authors:  Yueguang Gu; Chaoting Yan; Zhongyi Yan; Xiaochen Wang; Li Yue; Lei Li
Journal:  Transl Pediatr       Date:  2022-07

2.  The effect of mandibular flexure on the design of implant-supported fixed restorations of different facial types under two loading conditions by three-dimensional finite element analysis.

Authors:  Jing Gao; Xuejing Li; Jing He; Lulu Jiang; Baohong Zhao
Journal:  Front Bioeng Biotechnol       Date:  2022-08-29

Review 3.  Buccal Bone Thickness in Anterior and Posterior Teeth-A Systematic Review.

Authors:  Diana Heimes; Eik Schiegnitz; Robert Kuchen; Peer W Kämmerer; Bilal Al-Nawas
Journal:  Healthcare (Basel)       Date:  2021-11-30
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.