Literature DB >> 19106265

Accuracy of three-dimensional measurements obtained from cone beam computed tomography surface-rendered images for cephalometric analysis: influence of patient scanning position.

Bassam Hassan1, Paul van der Stelt, Gerard Sanderink.   

Abstract

The aims of this study were to assess the accuracy of linear measurements on three-dimensional (3D) surface-rendered images generated from cone beam computed tomography (CBCT) in comparison with two-dimensional (2D) slices and 2D lateral and postero-anterior (PA) cephalometric projections, and to investigate the influence of patient head position in the scanner on measurement accuracy. Eight dry human skulls were scanned twice using NewTom 3G CBCT in an ideal and a rotated position and the resulting datasets were used to create 3D surface-rendered images, 2D tomographic slices, and 2D lateral and PA projections. Ten linear distances were defined for cephalometric measurements. The physical and radiographic measurements were repeated twice by three independent observers and were compared using repeated measures analysis of variance (P=0.05). The radiographic measurements were also compared between the ideal and the rotated scan positions. The radiographic measurements of the 3D images were closer to the physical measurements than the 2D slices and 2D projection images. No statistically significant difference was found between the ideal and the rotated scan measurements for the 3D images and the 2D tomographic slices. A statistically significant difference (P<0.001) was observed between the ideal and rotated scan positions for the 2D projection images. The findings indicate that measurements based on 3D CBCT surface images are accurate and that small variations in the patient's head position do not influence measurement accuracy.

Entities:  

Mesh:

Year:  2008        PMID: 19106265     DOI: 10.1093/ejo/cjn088

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  57 in total

1.  3D cephalometric analysis obtained from computed tomography. Review of the literature.

Authors:  Giulia Rossini; Costanza Cavallini; Michele Cassetta; Ersilia Barbato
Journal:  Ann Stomatol (Roma)       Date:  2012-01-27

2.  Comparison of linear and angular measurements using two-dimensional conventional methods and three-dimensional cone beam CT images reconstructed from a volumetric rendering program in vivo.

Authors:  U Oz; K Orhan; N Abe
Journal:  Dentomaxillofac Radiol       Date:  2011-12       Impact factor: 2.419

3.  Accuracy of CBCT measurements of a human skull.

Authors:  Kivanç Kamburoğlu; Eray Kolsuz; Hakan Kurt; Cenk Kiliç; Tuncer Özen; Candan Semra Paksoy
Journal:  J Digit Imaging       Date:  2011-10       Impact factor: 4.056

Review 4.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

5.  Evaluation of bifid mandibular canals with cone-beam computed tomography in a Turkish adult population: a retrospective study.

Authors:  Kaan Orhan; Seçil Aksoy; Burak Bilecenoglu; Bayram Ufuk Sakul; Candan Semra Paksoy
Journal:  Surg Radiol Anat       Date:  2010-12-16       Impact factor: 1.246

6.  Accuracy of 3D cephalometric measurements based on an automatic knowledge-based landmark detection algorithm.

Authors:  Abhishek Gupta; Om Prakash Kharbanda; Viren Sardana; Rajiv Balachandran; Harish Kumar Sardana
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-12-24       Impact factor: 2.924

7.  Evaluation of the morphological changes in the mandible for dentate and totally edentate elderly population using cone-beam computed tomography.

Authors:  Ummühan Tozoğlu; Binali Cakur
Journal:  Surg Radiol Anat       Date:  2013-11-29       Impact factor: 1.246

8.  Reliability and reproducibility of linear mandible measurements with the use of a cone-beam computed tomography and two object inclinations.

Authors:  C Tomasi; E Bressan; B Corazza; S Mazzoleni; E Stellini; A Lith
Journal:  Dentomaxillofac Radiol       Date:  2011-05       Impact factor: 2.419

9.  Accuracy of linear measurement using cone-beam computed tomography at different reconstruction angles.

Authors:  Sima Nikneshan; Shadi Hamidi Aval; Neema Bakhshalian; Shahriyar Shahab; Mahdis Mohammadpour; Soodeh Sarikhani
Journal:  Imaging Sci Dent       Date:  2014-11-25

10.  Influence of scanning and reconstruction parameters on quality of three-dimensional surface models of the dental arches from cone beam computed tomography.

Authors:  Bassam Hassan; Paulo Couto Souza; Reinhilde Jacobs; Soraya de Azambuja Berti; Paul van der Stelt
Journal:  Clin Oral Investig       Date:  2009-06-09       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.