Literature DB >> 21803252

Accuracy and reliability of cone-beam computed tomography measurements: Influence of head orientation.

Amr Ragab El-Beialy1, Mona Salah Fayed, Ahmed Mohammed El-Bialy, Yehya A Mostafa.   

Abstract

INTRODUCTION: The purpose of this research is to determine the accuracy and reliability of measurements obtained from 3-dimensional (3D) cone-beam computed tomography (CBCT) for different head orientations.
METHODS: Stainless steel wires were fixed to a dry skull at different places. The skull was scanned by using CBCT in the centered and 5 other positions. Intraobserver and interobserver reliability tests were performed by using 6 landmarks identified on the virtual 3D skulls by 2 operators. Two methods were used to determine the accuracy of measurements on the virtual 3D skull scanned in different positions. In the first method, 12 linear distances were compared on the physical skull and the 3D virtual skull in the centered and the other scanning positions. In the second method, registration of each of the 5 positions on the centered position was done separately, and coordinates of 11 landmarks were identified in each position and compared with the centered position. Data gathered from the 2 methods were compared statistically.
RESULTS: Concordance correlation and Pearson correlation coefficients values were almost 0.9999 in all the comparisons denoting: (1) high intraobserver and interobserver reliability; (2) very high concordance between the physical skull and the CBCT centered-position measurements; (3) very high concordance between measurements of the centered position in relation to those obtained from the different skull positions; and (4) registration of the skulls in the different positions showed high concordance, with the highest values between the centered and off-centered positions, and the lowest with the complex position.
CONCLUSIONS: Accuracy and reliability of CBCT measurements are not affected by changing the skull orientation. Thus, the upper-lip and chin rests should not be considered absolute requirements during CBCT imaging if a stable head position is ensured.
Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21803252     DOI: 10.1016/j.ajodo.2010.03.030

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  16 in total

1.  Dry skull positioning device for extra-oral radiology and cone-beam CT.

Authors:  Thiago Leite Beaini; Paulo Eduardo Miamoto Dias; Rodolfo Francisco Haltenhoff Melani
Journal:  Int J Legal Med       Date:  2013-08-29       Impact factor: 2.686

2.  Mandibular and glenoid fossa changes after bone-anchored maxillary protraction therapy in patients with UCLP: A 3-D preliminary assessment.

Authors:  Marilia Yatabe; Daniela Garib; Renato Faco; Hugo de Clerck; Bernardo Souki; Guilherme Janson; Tung Nguyen; Lucia Cevidanes; Antonio Ruellas
Journal:  Angle Orthod       Date:  2016-09-26       Impact factor: 2.079

3.  The influence of two photobiomodulation protocols on orthodontically induced inflammatory root resorption (a randomized controlled clinical trial).

Authors:  Farah Y Eid; Walid A El-Kenany; Mohamed I Mowafy; Ahmed R El-Kalza
Journal:  BMC Oral Health       Date:  2022-06-05       Impact factor: 3.747

4.  The Effect of Mandibular Angulation on Preoperative Assessment of Dental Implant Insertion at Premolar Region: CBCT Study.

Authors:  Sadaf Sadat Mahmoudinezhad; Azarnoosh AryanKia; Sanaz Sharifi Shooshtari; Kooshan Moradi
Journal:  Biomed Res Int       Date:  2022-05-28       Impact factor: 3.246

5.  Common 3-dimensional coordinate system for assessment of directional changes.

Authors:  Antonio Carlos de Oliveira Ruellas; Cristiano Tonello; Liliane Rosas Gomes; Marilia Sayako Yatabe; Lucie Macron; Julia Lopinto; Joao Roberto Goncalves; Daniela Gamba Garib Carreira; Nivaldo Alonso; Bernardo Quiroga Souki; Raildo da Silva Coqueiro; Lucia Helena Soares Cevidanes
Journal:  Am J Orthod Dentofacial Orthop       Date:  2016-05       Impact factor: 2.650

6.  Influence of cone beam CT volume orientation on alveolar bone measurements in patients with different facial profiles.

Authors:  Eliana Dantas Costa; Priscila Dias Peyneau; Glaucia Maria Bovi Ambrosano; Matheus Lima Oliveira
Journal:  Dentomaxillofac Radiol       Date:  2019-03-28       Impact factor: 2.419

Review 7.  Methods to quantify soft-tissue based facial growth and treatment outcomes in children: a systematic review.

Authors:  Sander Brons; Machteld E van Beusichem; Ewald M Bronkhorst; Jos Draaisma; Stefaan J Bergé; Thomas J Maal; Anne Marie Kuijpers-Jagtman
Journal:  PLoS One       Date:  2012-08-06       Impact factor: 3.240

8.  Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography.

Authors:  Hanadi Sabban; Mina Mahdian; Ajay Dhingra; Alan G Lurie; Aditya Tadinada
Journal:  Imaging Sci Dent       Date:  2015-06-19

9.  Cone-beam computed tomography based evaluation of rotational patterns of dentofacial structures in skeletal Class III deformity with mandibular asymmetry.

Authors:  Hyeong-Seok Ryu; Ki-Yong An; Kyung-Hwa Kang
Journal:  Korean J Orthod       Date:  2015-07-24       Impact factor: 1.372

10.  3D Rapid Prototyping for Otolaryngology-Head and Neck Surgery: Applications in Image-Guidance, Surgical Simulation and Patient-Specific Modeling.

Authors:  Harley H L Chan; Jeffrey H Siewerdsen; Allan Vescan; Michael J Daly; Eitan Prisman; Jonathan C Irish
Journal:  PLoS One       Date:  2015-09-02       Impact factor: 3.240

View more