Literature DB >> 30853785

Energy Harvesting and Sensing with Embedded Piezoelectric Ceramics in Knee Implants.

Mohsen Safaei1, R Michael Meneghini2, Steven R Anton1.   

Abstract

The knee replacement is one of the most common orthopedic surgical interventions in the United States; however, recent studies have shown up to 20% of patients are dissatisfied with the outcome. One of the key issues to improving these operations is a better understanding of the ligamentous balance during and after surgery. The goal of this work is to investigate the feasibility of embedding piezoelectric transducers in the polyethylene bearing of a total knee replacement to act as self-powered sensors to aid in the alignment and balance of the knee replacement by providing intra- and postoperative feedback to the surgeon. A model consisting of a polyethylene disc with a single embedded piezoelectric ceramic transducer is investigated as a basis for future work. A modeling framework is developed including a biomechanical model of the knee joint, a finite element model of the knee bearing with encapsulated transducer, and an electromechanical model of the piezoelectric transducer. Model predictions show that a peak voltage of 2.3 V with a load resistance of 1.01 MΩ can be obtained from a single embedded piezoelectric stack, and an average power of 12 μW can be obtained from a knee bearing with four embedded piezoelectric transducers. Uniaxial compression testing is also performed on a fabricated sample for model validation. The results found in this work show promising potential of embedded piezoelectric transducers to be utilized for autonomous, self-powered in vivo knee implant force sensors.

Entities:  

Keywords:  Energy harvesting; orthopedic implant; piezoelectric sensing; self-powered sensors; total knee replacement

Year:  2018        PMID: 30853785      PMCID: PMC6404984          DOI: 10.1109/TMECH.2018.2794182

Source DB:  PubMed          Journal:  IEEE ASME Trans Mechatron        ISSN: 1083-4435            Impact factor:   5.303


  23 in total

Review 1.  Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty.

Authors:  S M Kurtz; O K Muratoglu; M Evans; A A Edidin
Journal:  Biomaterials       Date:  1999-09       Impact factor: 12.479

2.  Cyclic steady state stress-strain behavior of UHMW polyethylene.

Authors:  D J Krzypow; C M Rimnac
Journal:  Biomaterials       Date:  2000-10       Impact factor: 12.479

3.  A multiaxial force-sensing implantable tibial prosthesis.

Authors:  Bryan Kirking; Janet Krevolin; Christopher Townsend; Clifford W Colwell; Darryl D D'Lima
Journal:  J Biomech       Date:  2006       Impact factor: 2.712

4.  Consideration of impedance matching techniques for efficient piezoelectric energy harvesting.

Authors:  Hyeoungwoo Kim; Shashank Priya; Harry Stephanou; Kenji Uchino
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-09       Impact factor: 2.725

5.  Tibial forces measured in vivo after total knee arthroplasty.

Authors:  Darryl D D'Lima; Shantanu Patil; Nikolai Steklov; John E Slamin; Clifford W Colwell
Journal:  J Arthroplasty       Date:  2006-02       Impact factor: 4.757

6.  In vivo knee moments and shear after total knee arthroplasty.

Authors:  Darryl D D'Lima; Shantanu Patil; Nikolai Steklov; Shu Chien; Clifford W Colwell
Journal:  J Biomech       Date:  2007-04-25       Impact factor: 2.712

7.  Soft tissue balance measurement in anterior cruciate ligament-resected knee joint: cadaveric study as a model for cruciate-retaining total knee arthroplasty.

Authors:  Koichi Tanaka; Hirotsugu Muratsu; Kiyonori Mizuno; Ryosuke Kuroda; Shinichi Yoshiya; Masahiro Kurosaka
Journal:  J Orthop Sci       Date:  2007-03-30       Impact factor: 1.601

8.  A bioengineering analysis of force actions at the knee in normal and pathological gait.

Authors:  I J Harrington
Journal:  Biomed Eng       Date:  1976-05

9.  OpenSim: open-source software to create and analyze dynamic simulations of movement.

Authors:  Scott L Delp; Frank C Anderson; Allison S Arnold; Peter Loan; Ayman Habib; Chand T John; Eran Guendelman; Darryl G Thelen
Journal:  IEEE Trans Biomed Eng       Date:  2007-11       Impact factor: 4.538

10.  Patient satisfaction after total knee arthroplasty: who is satisfied and who is not?

Authors:  Robert B Bourne; Bert M Chesworth; Aileen M Davis; Nizar N Mahomed; Kory D J Charron
Journal:  Clin Orthop Relat Res       Date:  2010-01       Impact factor: 4.176

View more
  8 in total

1.  Parametric Study of a Triboelectric Transducer in Total Knee Replacement Application.

Authors:  Alwathiqbellah Ibrahim; Geofrey Yamomo; Ryan Willing; Shahrzad Towfighian
Journal:  J Intell Mater Syst Struct       Date:  2020-08-20       Impact factor: 2.569

2.  Characterization of a packaged triboelectric harvester under simulated gait loading for total knee replacement.

Authors:  Nabid Aunjum Hossain; Geofrey George Yamomo; Ryan Willing; Shahrzad Towfighian
Journal:  IEEE ASME Trans Mechatron       Date:  2021-01-06       Impact factor: 5.303

3.  Self-Powered Load Sensing Circuitry for Total Knee Replacement.

Authors:  Manav Jain; Nabid Aunjum Hossain; Shahrzad Towfighian; Ryan Willing; Milutin Stanaćević; Emre Salman
Journal:  IEEE Sens J       Date:  2021-09-03       Impact factor: 4.325

4.  Fabrication and selection of surrogate knee implant bearings for experimental evaluation of embedded in-vivo sensors.

Authors:  Robert I Ponder; Mohsen Safaei; Steven R Anton
Journal:  J Mech Behav Biomed Mater       Date:  2018-12-18

5.  Design and analysis of a compliant 3D printed energy harvester housing for knee implants.

Authors:  Geofrey Yamomo; Nabid Hossain; Shahrzad Towfighian; Ryan Willing
Journal:  Med Eng Phys       Date:  2021-01-04       Impact factor: 2.242

6.  Effect of Dielectric Material and Package Stiffness on the Power Generation in a Packaged Triboelectric Energy Harvesting System for Total Knee Replacement.

Authors:  Nabid Aunjum Hossain; Geofrey George Yamomo; Ryan Willing; Shahrzad Towfighian
Journal:  J Biomech Eng       Date:  2021-10-01       Impact factor: 1.899

Review 7.  Bioelectronic multifunctional bone implants: recent trends.

Authors:  Marco P Soares Dos Santos; Rodrigo M C Bernardo
Journal:  Bioelectron Med       Date:  2022-09-21

8.  Performance of a Piezoelectric Energy Harvesting System for an Energy-Autonomous Instrumented Total Hip Replacement: Experimental and Numerical Evaluation.

Authors:  Hans-E Lange; Nils Arbeiter; Rainer Bader; Daniel Kluess
Journal:  Materials (Basel)       Date:  2021-09-08       Impact factor: 3.623

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.