Literature DB >> 34924739

Characterization of a packaged triboelectric harvester under simulated gait loading for total knee replacement.

Nabid Aunjum Hossain1, Geofrey George Yamomo2, Ryan Willing2, Shahrzad Towfighian1.   

Abstract

Load sensing total knee replacement (TKR) implants are useful tools for monitoring prosthesis health and providing quantitative data to support patient claims of pain or instability. However, powering such devices throughout the entire life of the knee replacement is a challenge, and self-powered telemetry via energy harvesting is an attractive solution. In this study, we implemented vertical contact mode triboelectric energy harvesters inside a knee implant package to generate the power required for embedded digitization and communications circuitry. The harvesters produce small-scale electric power from physiologically relevant loads transmitted through the knee. Experiments were performed on a joint motion simulator with an instrumented package prototype between the polyethylene bearing and tibial tray. The amplitude and the pattern of the power output varied with the input loadings. Under sinusoidal loading the maximum apparent power harvested was around 7μW at (50-2000)N whereas, under vertical compressive gait loading the harvesters generated around 10μW at average human knee loads of (151-1950)N and 20μW when the maximum applied load was increased by 25%. Full six degrees of freedom (6-DoF) gait load/motions at 0.67Hz produced 50% less power due to the slower loading rate. The results show the potential of developing a triboelectric energy harvesting-based self-powered instrumented knee implant for long-term in vivo knee joint force measurement.

Entities:  

Keywords:  Biomedical sensor; In vivo force measurement; Joint motion simulator; Knee implant package prototype; Total knee replacement; Triboelectric energy harvesting

Year:  2021        PMID: 34924739      PMCID: PMC8682802          DOI: 10.1109/tmech.2021.3049327

Source DB:  PubMed          Journal:  IEEE ASME Trans Mechatron        ISSN: 1083-4435            Impact factor:   5.303


  24 in total

1.  Design and evaluation of instrumented smart knee implant.

Authors:  Shaban Almouahed; Manuel Gouriou; Chafiaa Hamitouche; Eric Stindel; Christian Roux
Journal:  IEEE Trans Biomed Eng       Date:  2010-07-15       Impact factor: 4.538

2.  Trends in epidemiology of knee arthroplasty in the United States, 1990-2000.

Authors:  Nitin B Jain; Laurence D Higgins; Donald Ozumba; Ulrich Guller; McNeil Cronin; Ricardo Pietrobon; Jeffrey N Katz
Journal:  Arthritis Rheum       Date:  2005-12

3.  Why do revision knee arthroplasties fail?

Authors:  Juan Suarez; William Griffin; Bryan Springer; Thomas Fehring; J Bohannon Mason; Susan Odum
Journal:  J Arthroplasty       Date:  2008-06-05       Impact factor: 4.757

4.  Transparent triboelectric nanogenerators and self-powered pressure sensors based on micropatterned plastic films.

Authors:  Feng-Ru Fan; Long Lin; Guang Zhu; Wenzhuo Wu; Rui Zhang; Zhong Lin Wang
Journal:  Nano Lett       Date:  2012-05-11       Impact factor: 11.189

5.  Triboelectric active sensor array for self-powered static and dynamic pressure detection and tactile imaging.

Authors:  Long Lin; Yannan Xie; Sihong Wang; Wenzhuo Wu; Simiao Niu; Xiaonan Wen; Zhong Lin Wang
Journal:  ACS Nano       Date:  2013-08-19       Impact factor: 15.881

6.  A Smart Knee Implant Using Triboelectric Energy Harvesters.

Authors:  Alwathiqbellah Ibrahim; Manav Jain; Emre Salman; Ryan Willing; Shahrzad Towfighian
Journal:  Smart Mater Struct       Date:  2019-01-25       Impact factor: 3.585

7.  Estimating the burden of total knee replacement in the United States.

Authors:  Alexander M Weinstein; Benjamin N Rome; William M Reichmann; Jamie E Collins; Sara A Burbine; Thomas S Thornhill; John Wright; Jeffrey N Katz; Elena Losina
Journal:  J Bone Joint Surg Am       Date:  2013-03-06       Impact factor: 5.284

8.  Prevalence of Total Hip and Knee Replacement in the United States.

Authors:  Hilal Maradit Kremers; Dirk R Larson; Cynthia S Crowson; Walter K Kremers; Raynard E Washington; Claudia A Steiner; William A Jiranek; Daniel J Berry
Journal:  J Bone Joint Surg Am       Date:  2015-09-02       Impact factor: 5.284

9.  Why are total knee arthroplasties failing today--has anything changed after 10 years?

Authors:  Peter F Sharkey; Paul M Lichstein; Chao Shen; Anthony T Tokarski; Javad Parvizi
Journal:  J Arthroplasty       Date:  2014-07-05       Impact factor: 4.757

10.  Analysis of mechanical deformation effect on the voltage generation of a vertical contact mode triboelectric generator.

Authors:  Nabid Aunjum Hossain; Mir Jalil Razavi; Shahrzad Towfighian
Journal:  J Micromech Microeng       Date:  2020-03-02       Impact factor: 1.881

View more
  2 in total

Review 1.  Advanced Implantable Biomedical Devices Enabled by Triboelectric Nanogenerators.

Authors:  Chan Wang; Qiongfeng Shi; Chengkuo Lee
Journal:  Nanomaterials (Basel)       Date:  2022-04-15       Impact factor: 5.719

2.  Self-Powered Load Sensing Circuitry for Total Knee Replacement.

Authors:  Manav Jain; Nabid Aunjum Hossain; Shahrzad Towfighian; Ryan Willing; Milutin Stanaćević; Emre Salman
Journal:  IEEE Sens J       Date:  2021-09-03       Impact factor: 4.325

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.