Literature DB >> 10725880

Three-dimensional whole body imaging of spin probes in mice by time-domain radiofrequency electron paramagnetic resonance.

M Afeworki1, G M van Dam, N Devasahayam, R Murugesan, J Cook, D Coffin, J H Larsen, J B Mitchell, S Subramanian, M C Krishna.   

Abstract

Imaging of stable paramagnetic spin probes in phantom objects and in vivo was evaluated using a RF time domain EPR spectrometer/imager operating at 300 MHz. Projections were collected using static magnetic field gradients and images were reconstructed using filtered back-projection techniques. Results from phantom objects containing approximately 10(17) spins of stable paramagnetic probes with single narrow EPR spectra provide three-dimensional spatial images with resolution better than 2 mm. When the spin probe was administered to mice, the spin probe accumulation was temporally observed in the thoracic, abdominal, and pelvic regions. A three-dimensional image (from 144 projections) from a live mouse was collected in 5 min. Using fiducial markers, the spin probe accumulation in organs such as liver, kidney, and bladder could be observed. Differences in the oxygen status between liver and kidney were observed from the EPR images from mice administered with spin probe, by treating the time-domain responses with convolution difference approach, prior to image reconstruction. The results from these studies suggest that, with the use of stable paramagnetic spin probes and time-domain RF EPR, it is possible to perform in vivo imaging on animals and also obtain important spatially resolved physiologic information.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10725880     DOI: 10.1002/(sici)1522-2594(200003)43:3<375::aid-mrm9>3.0.co;2-g

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  13 in total

1.  Integration of digital signal processing technologies with pulsed electron paramagnetic resonance imaging.

Authors:  Randall H Pursley; Ghadi Salem; Nallathamby Devasahayam; Sankaran Subramanian; Janusz Koscielniak; Murali C Krishna; Thomas J Pohida
Journal:  J Magn Reson       Date:  2005-10-21       Impact factor: 2.229

2.  Direct detection and time-locked subsampling applied to pulsed electron paramagnetic resonance imaging.

Authors:  Randall H Pursley; Ghadi Salem; Thomas J Pohida; Nallathamby Devasahayam; Sankaran Subramanian; Murali C Krishna
Journal:  Rev Sci Instrum       Date:  2005-05       Impact factor: 1.523

3.  Frequency bandwidth extension by use of multiple Zeeman field offsets for electron spin-echo EPR oxygen imaging of large objects.

Authors:  Payam Seifi; Boris Epel; Subramanian V Sundramoorthy; Colin Mailer; Howard J Halpern
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

4.  250 MHz Rapid Scan Cross Loop Resonator.

Authors:  Laura A Buchanan; Lukas B Woodcock; George A Rinard; Richard W Quine; Yilin Shi; Sandra S Eaton; Gareth R Eaton
Journal:  Appl Magn Reson       Date:  2018-10-03       Impact factor: 0.831

5.  Reactivity of molecular oxygen with ethoxycarbonyl derivatives of tetrathiatriarylmethyl radicals.

Authors:  Shijing Xia; Frederick A Villamena; Christopher M Hadad; Periannan Kuppusamy; Yunbo Li; Hong Zhu; Jay L Zweier
Journal:  J Org Chem       Date:  2006-09-15       Impact factor: 4.354

6.  Quantifying the effects of anesthesia on intracellular oxygen via low-cost portable microscopy using dual-emissive nanoparticles.

Authors:  Ashlyn G Rickard; Meng Zhuang; Christopher A DeRosa; Mark W Dewhirst; Cassandra L Fraser; Gregory M Palmer
Journal:  Biomed Opt Express       Date:  2022-06-09       Impact factor: 3.562

7.  Resonators for In Vivo Imaging: Practical Experience.

Authors:  George A Rinard; Richard W Quine; Laura A Buchanan; Sandra S Eaton; Gareth R Eaton; Boris Epel; Subramanian V Sundramoorthy; Howard J Halpern
Journal:  Appl Magn Reson       Date:  2017-09-22       Impact factor: 0.831

8.  A loop resonator for slice-selective in vivo EPR imaging in rats.

Authors:  Hiroshi Hirata; Guanglong He; Yuanmu Deng; Ildar Salikhov; Sergey Petryakov; Jay L Zweier
Journal:  J Magn Reson       Date:  2007-10-30       Impact factor: 2.229

9.  Stochastic excitation and Hadamard correlation spectroscopy with bandwidth extension in RF FT-EPR.

Authors:  Randall H Pursley; John Kakareka; Ghadi Salem; Nallathamby Devasahayam; Sankaran Subramanian; Rolf G Tschudin; Murali C Krishna; Thomas J Pohida
Journal:  J Magn Reson       Date:  2003-05       Impact factor: 2.229

Review 10.  Hypoxia Imaging As a Guide for Hypoxia-Modulated and Hypoxia-Activated Therapy.

Authors:  Jeffrey R Brender; Yu Saida; Nallathamby Devasahayam; Murali C Krishna; Shun Kishimoto
Journal:  Antioxid Redox Signal       Date:  2022-01       Impact factor: 8.401

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.