Literature DB >> 19721036

Ceramic-on-metal bearings in total hip replacement: whole blood metal ion levels and analysis of retrieved components.

G H Isaac1, C Brockett, A Breckon, D van der Jagt, S Williams, C Hardaker, J Fisher, A Schepers.   

Abstract

This study reports on ceramic-on-metal (CoM) bearings in total hip replacement. Whole blood metal ion levels were measured. The median increase in chromium and cobalt at 12 months was 0.08 microg/1 and 0.22 microg/1, respectively, in CoM bearings. Comparable values for metal-on-metal (MoM) were 0.48 microg/1 and 0.32 microg/1. The chromium levels were significantly lower in CoM than in MoM bearings (p = 0.02). The cobalt levels were lower, but the difference was not significant. Examination of two explanted ceramic heads revealed areas of thin metal transfer. CoM bearings (one explanted head and acetabular component, one explanted head and new acetabular component, and three new heads and acetabular components) were tested in a hip joint simulator. The explanted head and acetabular component had higher bedding-in. However, after one million cycles all the wear rates were the same and an order of magnitude less than that reported for MoM bearings. There were four outliers in each clinical group, primarily related to component malposition.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19721036     DOI: 10.1302/0301-620X.91B9.22306

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  14 in total

1.  Metal-on-metal: history, state of the art (2010).

Authors:  Philippe Triclot
Journal:  Int Orthop       Date:  2011-01-14       Impact factor: 3.075

Review 2.  [Total hip arthroplasty in young patients : Bearings and custom-made prostheses].

Authors:  C Benignus; M Morlock; J Beckmann
Journal:  Orthopade       Date:  2019-04       Impact factor: 1.087

3.  No Difference in Reoperations at 2 Years Between Ceramic-on-metal and Metal-on-metal THA: A Randomized Trial.

Authors:  C Anderson Engh; Supatra Sritulanondha; Abigail Korczak; Terrence David Whalen; Douglas D R Naudie; Richard W McCalden; Steven J MacDonald
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

4.  Trunnionosis: A pain in the neck.

Authors:  Philip S Pastides; Matthew Dodd; Khaled M Sarraf; Charles A Willis-Owen
Journal:  World J Orthop       Date:  2013-10-18

5.  Wear performance of ceramic-on-metal hip bearings.

Authors:  Jörn Reinders; Robert Sonntag; Christian Heisel; Tobias Reiner; Leo Vot; Jan Philippe Kretzer
Journal:  PLoS One       Date:  2013-08-29       Impact factor: 3.240

6.  Future bearing surfaces in total hip arthroplasty.

Authors:  Jun-Dong Chang
Journal:  Clin Orthop Surg       Date:  2014-02-14

7.  Adverse reaction to metal debris in a patient with acetabular shell loosening 8 years after ceramic-on-metal total hip arthroplasty.

Authors:  Benjamin R Pulley; Thai Q Trinh; Jared C Bentley; Joel R Politi
Journal:  Arthroplast Today       Date:  2015-10-21

8.  Pseudotumour Complicated by Implant Loosening One Year After revision Ceramic on Metal Total Hip Arthroplasty: A Case Report.

Authors:  Devendra Lakhotia; Prashant Kumar
Journal:  J Orthop Case Rep       Date:  2017 Jan-Feb

9.  Clinical Results and Serum Metal Ion Concentrations following Ceramic-on-Metal Total Hip Arthroplasty at a Mean Follow-Up of 60 Months.

Authors:  W Maurer-Ertl; D Pranckh-Matzke; J Friesenbichler; G Bratschitsch; L A Holzer; M Maier; A Leithner
Journal:  Biomed Res Int       Date:  2017-03-08       Impact factor: 3.411

Review 10.  Prevalence of Failure due to Adverse Reaction to Metal Debris in Modern, Medium and Large Diameter Metal-on-Metal Hip Replacements--The Effect of Novel Screening Methods: Systematic Review and Metaregression Analysis.

Authors:  Aleksi Reito; Olli Lainiala; Petra Elo; Antti Eskelinen
Journal:  PLoS One       Date:  2016-03-01       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.