Non-invasive Small Vessel Imaging of Human Thyroid Using Motion-Corrected Spatiotemporal Clutter Filtering.

Rohit Nayak1, Viksit Kumar2, Jeremy Webb1, Mostafa Fatemi2, Azra Alizad3.   

Abstract

Reliable assessment of small vessel blood flow in the thyroid, without using any contrast agents, can be challenging because of increased physiological motion resulting from its proximity to the pulsating carotid artery. In this study, we hypothesized that correction of tissue motion prior to singular value decomposition (SVD)-based clutter filtering can improve the coherency of the tissue components and, thus, may allow better clutter suppression and visualization of small vessels in the thyroid. We corroborated this hypothesis by conducting phantom and in vivo studies using a clinical ultrasound scanner implemented with compounded plane wave imaging. The phantom studies were conducted using a homogeneous tissue-mimicking phantom to study the impact of motion on the covariance of the spatiotemporal Doppler data, in the absence of blood activity. The non-invasive in vivo study was conducted on a 74-y-old woman with a thyroid nodule suspicious of malignancy. A rigid body-based motion correction was performed using tissue displacements obtained from 2-D normalized cross-correlation-based speckle tracking. Subsequently, the power Doppler images were computed using SVD-based spatiotemporal clutter filtering. The results from the phantom study revealed that motion can considerably reduce the covariance of the spatiotemporal data and, thus, increase the rank of the tissue components. When the phantom was subjected to a total translation displacement of 6 pixels over the entire ensemble, in each direction (axial and lateral), the covariance dropped by more than 25%. The results obtained from the non-invasive in vivo study indicated that visualization of small vessel blood flow improved with motion correction of the power Doppler ensemble. The contrast-to-noise ratio of the blood signal in motion-corrected power Doppler images was considerably higher (8.17 and 8.32 dB), compared with that obtained using the standard SVD approach at an optimal threshold (0.87 and 4.33 dB) and a lower singular value threshold (1.92 and 3.05 dB). Further, the covariance of the in vivo thyroid spatiotemporal data increased by approximately 10% with motion correction. These preliminary results indicate that motion correction can be used to improve the visualization of small vessel blood flow in the thyroid, without using any contrast agents. The results of this feasibility study were encouraging, and warrant further development and more in vivo validation in moving tissues and organs.
Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Compounded plane wave imaging; Cross-correlation; Microvasculature; Motion correction; Power Doppler; Small vessel imaging; Thyroid; displacement tracking

Mesh:

Year:  2019        PMID: 30718145      PMCID: PMC6391182          DOI: 10.1016/j.ultrasmedbio.2018.10.028

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  27 in total

Review 1.  Selected methods for imaging elastic properties of biological tissues.

Authors:  James F Greenleaf; Mostafa Fatemi; Michael Insana
Journal:  Annu Rev Biomed Eng       Date:  2003-04-10       Impact factor: 9.590

Review 2.  Eigen-based clutter filter design for ultrasound color flow imaging: a review.

Authors:  Alfred Yu; Lasse Lovstakken
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-05       Impact factor: 2.725

Review 3.  Imaging the elastic properties of tissue: the 20 year perspective.

Authors:  K J Parker; M M Doyley; D J Rubens
Journal:  Phys Med Biol       Date:  2010-11-30       Impact factor: 3.609

4.  Comparison of interpolating methods for image resampling.

Authors:  J Parker; R V Kenyon; D E Troxel
Journal:  IEEE Trans Med Imaging       Date:  1983       Impact factor: 10.048

5.  Spatiotemporal Clutter Filtering of Ultrafast Ultrasound Data Highly Increases Doppler and fUltrasound Sensitivity.

Authors:  Charlie Demené; Thomas Deffieux; Mathieu Pernot; Bruno-Félix Osmanski; Valérie Biran; Jean-Luc Gennisson; Lim-Anna Sieu; Antoine Bergel; Stéphanie Franqui; Jean-Michel Correas; Ivan Cohen; Olivier Baud; Mickael Tanter
Journal:  IEEE Trans Med Imaging       Date:  2015-04-30       Impact factor: 10.048

6.  Noninvasive carotid artery elastography using multielement synthetic aperture imaging: Phantom and in vivo evaluation.

Authors:  Rohit Nayak; Giovanni Schifitto; Marvin M Doyley
Journal:  Med Phys       Date:  2017-06-30       Impact factor: 4.071

7.  A Novel Microflow Phantom Dedicated to Ultrasound Microvascular Measurements.

Authors:  Virginie Grand-Perret; Jean-René Jacquet; Ingrid Leguerney; Baya Benatsou; Jean-Marc Grégoire; Georges Willoquet; Ayache Bouakaz; Nathalie Lassau; Stephanie Pitre-Champagnat
Journal:  Ultrason Imaging       Date:  2018-06-20       Impact factor: 1.578

8.  Noninvasive vascular elastography using plane-wave and sparse-array imaging.

Authors:  Sanghamithra Korukonda; Rohit Nayak; Nancy Carson; Giovanni Schifitto; Vikram Dogra; Marvin M Doyley
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-02       Impact factor: 2.725

9.  Angle independent ultrasonic detection of blood flow.

Authors:  G E Trahey; J W Allison; O T von Ramm
Journal:  IEEE Trans Biomed Eng       Date:  1987-12       Impact factor: 4.538

10.  Visualizing Angle-Independent Principal Strains in the Longitudinal View of the Carotid Artery: Phantom and In Vivo Evaluation.

Authors:  Rohit Nayak; Giovanni Schifitto; Marvin M Doyley
Journal:  Ultrasound Med Biol       Date:  2018-04-22       Impact factor: 2.998

View more
  4 in total

1.  Adaptive background noise bias suppression in contrast-free ultrasound microvascular imaging.

Authors:  Rohit Nayak; Mostafa Fatemi; Azra Alizad
Journal:  Phys Med Biol       Date:  2019-12-19       Impact factor: 3.609

2.  A Spatial Coherence Beamformer Design for Power Doppler Imaging.

Authors:  Kathryn Ozgun; Jaime Tierney; Brett Byram
Journal:  IEEE Trans Med Imaging       Date:  2019-11-14       Impact factor: 10.048

3.  Dynamic Filtering of Adherent and Non-adherent Microbubble Signals Using Singular Value Thresholding and Normalized Singular Spectrum Area Techniques.

Authors:  Elizabeth B Herbst; Alexander L Klibanov; John A Hossack; F William Mauldin
Journal:  Ultrasound Med Biol       Date:  2021-08-08       Impact factor: 2.998

4.  Texture Analysis on Ultrasound: The Effect of Time Gain Compensation on Histogram Metrics and Gray-Level Matrices.

Authors:  Giulio Vara; Arianna Rustici; Andrea Sechi; Cristina Mosconi; Vincenzo Lucidi; Rita Golfieri
Journal:  J Med Phys       Date:  2021-02-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.