Literature DB >> 30701439

Assessment of aortic valve tract dynamics using automatic tracking of 3D transesophageal echocardiographic images.

Sandro Queirós1,2,3,4, Pedro Morais5,6,7,8, Wolfgang Fehske9, Alexandros Papachristidis10, Jens-Uwe Voigt11, Jaime C Fonseca12, Jan D'hooge7, João L Vilaça5,6,8.   

Abstract

The assessment of aortic valve (AV) morphology is paramount for planning transcatheter AV implantation (TAVI). Nowadays, pre-TAVI sizing is routinely performed at one cardiac phase only, usually at mid-systole. Nonetheless, the AV is a dynamic structure that undergoes changes in size and shape throughout the cardiac cycle, which may be relevant for prosthesis selection. Thus, the aim of this study was to present and evaluate a novel software tool enabling the automatic sizing of the AV dynamically in three-dimensional (3D) transesophageal echocardiography (TEE) images. Forty-two patients who underwent preoperative 3D-TEE images were retrospectively analyzed using the software. Dynamic measurements were automatically extracted at four levels, including the aortic annulus. These measures were used to assess the software's ability to accurately and reproducibly quantify the conformational changes of the aortic root and were validated against automated sizing measurements independently extracted at distinct time points. The software extracted physiological dynamic measurements in less than 2 min, that were shown to be accurate (error 2.2 ± 26.3 mm2 and 0.0 ± 2.53 mm for annular area and perimeter, respectively) and highly reproducible (0.85 ± 6.18 and 0.65 ± 7.90 mm2 of intra- and interobserver variability, respectively, in annular area). Using the maximum or minimum measured values rather than mid-systolic ones for device sizing resulted in a potential change of recommended size in 7% and 60% of the cases, respectively. The presented software tool allows a fast, automatic and reproducible dynamic assessment of the AV morphology from 3D-TEE images, with the extracted measures influencing the device selection depending on the cardiac moment used to perform its sizing. This novel tool may thus ease and potentially increase the observer's confidence during prosthesis' size selection at the preoperative TAVI planning.

Entities:  

Keywords:  3D transesophageal echocardiography; Aortic valve sizing; Dynamic morphology assessment; Tracking software tool; Transcatheter aortic valve implantation

Mesh:

Year:  2019        PMID: 30701439     DOI: 10.1007/s10554-019-01532-w

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  32 in total

1.  Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy.

Authors:  Ashraf Hamdan; Victor Guetta; Eli Konen; Orly Goitein; Amit Segev; Ehud Raanani; Dan Spiegelstein; Ilan Hay; Elio Di Segni; Michael Eldar; Ehud Schwammenthal
Journal:  J Am Coll Cardiol       Date:  2012-01-10       Impact factor: 24.094

2.  Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery.

Authors:  Martin B Leon; Craig R Smith; Michael Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; David L Brown; Peter C Block; Robert A Guyton; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Pamela S Douglas; John L Petersen; Jodi J Akin; William N Anderson; Duolao Wang; Stuart Pocock
Journal:  N Engl J Med       Date:  2010-09-22       Impact factor: 91.245

Review 3.  Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve.

Authors:  Nicoló Piazza; Peter de Jaegere; Carl Schultz; Anton E Becker; Patrick W Serruys; Robert H Anderson
Journal:  Circ Cardiovasc Interv       Date:  2008-08       Impact factor: 6.546

4.  Guidelines on the management of valvular heart disease (version 2012).

Authors:  Alec Vahanian; Ottavio Alfieri; Felicita Andreotti; Manuel J Antunes; Gonzalo Barón-Esquivias; Helmut Baumgartner; Michael Andrew Borger; Thierry P Carrel; Michele De Bonis; Arturo Evangelista; Volkmar Falk; Bernard Iung; Patrizio Lancellotti; Luc Pierard; Susanna Price; Hans-Joachim Schäfers; Gerhard Schuler; Janina Stepinska; Karl Swedberg; Johanna Takkenberg; Ulrich Otto Von Oppell; Stephan Windecker; Jose Luis Zamorano; Marian Zembala
Journal:  Eur Heart J       Date:  2012-08-24       Impact factor: 29.983

5.  Conformational pulsatile changes of the aortic annulus: impact on prosthesis sizing by computed tomography for transcatheter aortic valve replacement.

Authors:  Philipp Blanke; Maximillian Russe; Jonathon Leipsic; Jochen Reinöhl; Ullrich Ebersberger; Pal Suranyi; Matthias Siepe; Gregor Pache; Mathias Langer; U Joseph Schoepf
Journal:  JACC Cardiovasc Interv       Date:  2012-09       Impact factor: 11.195

Review 6.  Standardized imaging for aortic annular sizing: implications for transcatheter valve selection.

Authors:  Albert M Kasel; Salvatore Cassese; Sabine Bleiziffer; Makoto Amaki; Rebecca T Hahn; Adnan Kastrati; Partho P Sengupta
Journal:  JACC Cardiovasc Imaging       Date:  2013-02

7.  Patient-specific modeling and quantification of the aortic and mitral valves from 4-D cardiac CT and TEE.

Authors:  Razvan Ioan Ionasec; Ingmar Voigt; Bogdan Georgescu; Yang Wang; Helene Houle; Fernando Vega-Higuera; Nassir Navab; Dorin Comaniciu
Journal:  IEEE Trans Med Imaging       Date:  2010-05-03       Impact factor: 10.048

Review 8.  A practical guide to multimodality imaging of transcatheter aortic valve replacement.

Authors:  Gerald S Bloomfield; Linda D Gillam; Rebecca T Hahn; Samir Kapadia; Jonathon Leipsic; Stamatios Lerakis; Murat Tuzcu; Pamela S Douglas
Journal:  JACC Cardiovasc Imaging       Date:  2012-04

9.  Demonstration of left ventricular outflow tract eccentricity by real time 3D echocardiography: implications for the determination of aortic valve area.

Authors:  Sanjay Doddamani; Ricardo Bello; Mark A Friedman; Anita Banerjee; James H Bowers; Bette Kim; Prashant R Vennalaganti; Robert J Ostfeld; Garet M Gordon; Divya Malhotra; Daniel M Spevack
Journal:  Echocardiography       Date:  2007-09       Impact factor: 1.724

10.  Mitral valve dynamics in severe aortic stenosis before and after aortic valve replacement.

Authors:  Wendy Tsang; Federico Veronesi; Lissa Sugeng; Lynn Weinert; Masaaki Takeuchi; Valluvan Jeevanandam; Roberto M Lang
Journal:  J Am Soc Echocardiogr       Date:  2013-04-17       Impact factor: 5.251

View more
  1 in total

Review 1.  Aortic Annular Sizing Using Novel Software in Three-Dimensional Transesophageal Echocardiography for Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.

Authors:  Chanrith Mork; Minjie Wei; Weixi Jiang; Jianli Ren; Haitao Ran
Journal:  Diagnostics (Basel)       Date:  2021-04-22
  1 in total