Literature DB >> 23489539

Standardized imaging for aortic annular sizing: implications for transcatheter valve selection.

Albert M Kasel1, Salvatore Cassese, Sabine Bleiziffer, Makoto Amaki, Rebecca T Hahn, Adnan Kastrati, Partho P Sengupta.   

Abstract

The safety and efficacy of transcatheter aortic valve replacement procedures are directly related to proper imaging. This report revisits the existing noninvasive and invasive approaches that have concurrently evolved to meet the demands for optimal selection and guidance of patients undergoing transcatheter aortic valve replacement. The authors summarize the published evidence and discuss the strengths and pitfalls of echocardiographic, computed tomographic, and calibrated aortic balloon valvuloplasty techniques in sizing the aortic valve annulus. Specific proposals for 3-dimensional tomographic reconstructions of complex 3-dimensional aortic root anatomy are provided for reducing intermodality variability in annular sizing. Finally, on the basis of the sizing approaches discussed in this review, the authors provide practical recommendations for balloon-expandable and self-expandable prostheses selection. Strategic use of echocardiographic, multislice computed tomographic, and angiographic data may provide complementary information for determining the anatomical suitability, efficacy, and safety of the procedure.
Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23489539     DOI: 10.1016/j.jcmg.2012.12.005

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  53 in total

1.  Initial clinical experience using the EchoNavigator(®)-system during structural heart disease interventions.

Authors:  Jan Balzer; Tobias Zeus; Katharina Hellhammer; Verena Veulemans; Silke Eschenhagen; Eva Kehmeier; Christian Meyer; Tienush Rassaf; Malte Kelm
Journal:  World J Cardiol       Date:  2015-09-26

2.  Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation.

Authors:  Peter Bernhardt; Christoph Rodewald; Julia Seeger; Birgid Gonska; Dominik Buckert; Michael Radermacher; Vinzenz Hombach; Wolfgang Rottbauer; Jochen Wöhrle
Journal:  Clin Res Cardiol       Date:  2015-09-22       Impact factor: 5.460

Review 3.  Guidance of transcatheter aortic valve replacement by echocardiography.

Authors:  Rebecca T Hahn
Journal:  Curr Cardiol Rep       Date:  2014-01       Impact factor: 2.931

Review 4.  Preventing Coronary Obstruction During Transcatheter Aortic Valve Replacement: From Computed Tomography to BASILICA.

Authors:  Robert J Lederman; Vasilis C Babaliaros; Toby Rogers; Jaffar M Khan; Norihiko Kamioka; Danny Dvir; Adam B Greenbaum
Journal:  JACC Cardiovasc Interv       Date:  2019-07-08       Impact factor: 11.195

5.  Assessment of aortic valve tract dynamics using automatic tracking of 3D transesophageal echocardiographic images.

Authors:  Sandro Queirós; Pedro Morais; Wolfgang Fehske; Alexandros Papachristidis; Jens-Uwe Voigt; Jaime C Fonseca; Jan D'hooge; João L Vilaça
Journal:  Int J Cardiovasc Imaging       Date:  2019-01-30       Impact factor: 2.357

6.  A prospective, non-randomized comparison of SAPIEN XT and CoreValve implantation in two sequential cohorts of patients with severe aortic stenosis.

Authors:  Albert Markus Kasel; Salvatore Cassese; Thomas Ischinger; Alexander Leber; Diethmar Antoni; Gotthard Riess; Jayshree Vogel; Adnan Kastrati; Walter Eichinger; Ellen Hoffmann
Journal:  Am J Cardiovasc Dis       Date:  2014-06-28

Review 7.  Aortic annulus sizing in stenotic bicommissural non-raphe-type bicuspid aortic valves: reconstructing a three-dimensional structure using only two hinge points.

Authors:  Antonio H Frangieh; Jonathan Michel; Oliver Deutsch; Michael Joner; Costanza Pellegrini; Tobias Rheude; Sabine Bleiziffer; Albert Markus Kasel
Journal:  Clin Res Cardiol       Date:  2018-06-14       Impact factor: 5.460

8.  Cardiovascular magnetic resonance as a reliable alternative to cardiovascular computed tomography and transesophageal echocardiography for aortic annulus valve sizing.

Authors:  Riccardo Faletti; Marco Gatti; Stefano Salizzoni; Laura Bergamasco; Rodolfo Bonamini; Domenica Garabello; Walter Grosso Marra; Michele La Torre; Mara Morello; Simona Veglia; Paolo Fonio; Mauro Rinaldi
Journal:  Int J Cardiovasc Imaging       Date:  2016-04-27       Impact factor: 2.357

9.  Echocardiographic outcomes of self-expandable CoreValve versus balloon-expandable Edwards SAPIEN XT valves: the comparison of two bioprosthesis implanted in a single centre.

Authors:  Dayimi Kaya; Zulkif Tanriverdi; Huseyin Dursun; Tugce Colluoglu
Journal:  Int J Cardiovasc Imaging       Date:  2016-06-09       Impact factor: 2.357

Review 10.  3D Printing Applications for Transcatheter Aortic Valve Replacement.

Authors:  Dmitry Levin; G Burkhard Mackensen; Mark Reisman; James M McCabe; Danny Dvir; Beth Ripley
Journal:  Curr Cardiol Rep       Date:  2020-02-17       Impact factor: 2.931

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.