The use of dense alumina-alumina ceramic combination in total hip replacement.

P Boutin1, P Christel, J M Dorlot, A Meunier, A de Roquancourt, D Blanquaert, S Herman, L Sedel, J Witvoet.   

Abstract

The purpose of this article was to review the laboratory and clinical performances since 1970 of a total hip prosthesis using alumina-alumina combination. The chemical and physical properties of dense alumina ceramic were studied in relation to biocompatibility, mechanical strength, and surface properties. Through the examination of 35 retrieved implants, it was found that the long-term success of alumina-alumina total hip replacement depends on both the ceramic microstructure (small grain size with uniform distribution, minimum porosity, absence of inclusions) and implant geometry (sphericity deviation +/- 1 micron, radius tolerance between components 7-10 microns). Alumina component wear and fractures have disappeared with the use of high-performance materials and severe manufacturing quality control. Examination of human biopsies from well-fixed prostheses showed that alumina particles deposits increase with time with only a low-grade macrophagic reaction. When loosening occurred, an inflammatory reaction appeared; this reaction was less striking than with loose metal-polyethylene prostheses, however. The long-term behavior of cementless alumina cup fixation depends upon initial positioning and stability; survivorship analysis of the cemented ceramic cups showed an 88% survival probability after 8 years with a 1.6% average annual probability of revision. The percentage of surviving was 100% after 8 years in patients who were less than 50 years old. Aseptic loosenings occurring at the cup-cement interface were assumed to be related to stress protection secondary to the high rigidity of the ceramic leading to a weakening of the spongious bone supporting the cement mantle. Good bone stock quality as well as high-quality ceramic appear to be the prerequisites for durable fixation of alumina sockets.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3069846     DOI: 10.1002/jbm.820221210

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  13 in total

1.  A squeaky reputation: the problem may be design-dependent.

Authors:  Javad Parvizi; Bahar Adeli; Justin C Wong; Camilo Restrepo; Richard H Rothman
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

2.  Seating of ceramic liners in the uncemented trident acetabular shell: is there really a problem?

Authors:  D W J Howcroft; A Qureshi; N M Graham
Journal:  Clin Orthop Relat Res       Date:  2009-07-07       Impact factor: 4.176

3.  Periprosthetic Joint Infection in Hip Arthroplasty: Is There an Association Between Infection and Bearing Surface Type?

Authors:  Rocco P Pitto; Laurent Sedel
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

4.  Clinical Faceoff: Instability After THA: The Potential Role of the Bearing Surface.

Authors:  Javad Parvizi; Laurent Sedel; Michael J Dunbar
Journal:  Clin Orthop Relat Res       Date:  2018-04       Impact factor: 4.176

Review 5.  Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty.

Authors:  Didier Hannouche; Amine Zaoui; Frédéric Zadegan; Laurent Sedel; Rémy Nizard
Journal:  Int Orthop       Date:  2010-12-30       Impact factor: 3.075

6.  Are ceramic-on-ceramic bearings in total hip arthroplasty associated with reduced revision risk for late dislocation?

Authors:  Rocco P Pitto; Mikaela Garland; Laurent Sedel
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

7.  Ceramic liner fracture and impingement in total hip arthroplasty.

Authors:  Amy Steinhoff; Victor Hakim; Richard H Walker; Clifford W Colwell; Steven N Copp
Journal:  HSS J       Date:  2014-10-21

8.  Nanoporous gold as a neural interface coating: effects of topography, surface chemistry, and feature size.

Authors:  Christopher A R Chapman; Hao Chen; Marianna Stamou; Juergen Biener; Monika M Biener; Pamela J Lein; Erkin Seker
Journal:  ACS Appl Mater Interfaces       Date:  2015-03-02       Impact factor: 9.229

Review 9.  History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene.

Authors:  Steven M Kurtz; Heather A Gawel; Jasmine D Patel
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

10.  Prostaglandin E2 level in tissue surrounding aseptic failed total hips. Effects of materials.

Authors:  L Sedel; J Simeon; A Meunier; J M Villette; S M Launay
Journal:  Arch Orthop Trauma Surg       Date:  1992       Impact factor: 3.067

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.