Literature DB >> 27249955

Periprosthetic Joint Infection in Hip Arthroplasty: Is There an Association Between Infection and Bearing Surface Type?

Rocco P Pitto1, Laurent Sedel2.   

Abstract

BACKGROUND: Preliminary studies have raised the question of whether certain prosthetic biomaterials used in total hip arthroplasty (THA) bearings are associated with increased risk of periprosthetic joint infection (PJI). For example, some observational data suggest the risk of PJI is higher with metal-on-metal bearings. However, it is not known whether other bearings-including ceramic bearings or metal-on-polyethylene bearings-may be associated with a higher or lower risk of PJI. QUESTIONS/PURPOSES: The objective of this study was to use a national arthroplasty registry to assess whether the choice of bearings-metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), ceramic-on-ceramic (CoC), or metal-on-metal (MoM)-is associated with differences in the risk of revision for deep infection, either (1) within 6 months or (2) over the entire period of observation, which spanned 15 years.
METHODS: Data from primary THAs were extracted from the New Zealand Joint Registry over a 15-year period. A total of 97,889 hips were available for analysis. Inclusion criterion was degenerative joint disease; exclusion criteria were previous surgery, trauma, and any other diagnosis (12,566 hips). We also excluded a small group of ceramic-on-metal THAs (429) with short followup. The median observation period of the selected group of hips (84,894) was 9 years (range, 1-15 years). The mean age of patients was 68 years (SD ± 11 years), and 52% were women. There were 54,409 (64%) MoP, 16,503 (19%) CoP, 9051 (11%) CoC, and 4931 (6%) MoM hip arthroplasties. Four hundred one hips were revised for deep infection. A multivariate assessment was carried out including the following risks factors available for analysis: age, sex, operating room type, use of body exhaust suits, THA fixation mode, and surgeon volume. Because of late introduction of data collection in the Registry, we were unable to include body mass index (BMI, recording started 2010) and medical comorbidities according to the American Society of Anesthesiologists class (ASA, recording started 2005) in the multivariate analysis.
RESULTS: The rate of early PJI (< 6 months) did not differ by bearing surface. In contrast, we observed a difference over the total observation period. Within the first 6 months after the index surgery, CoC THAs were not associated with a lower risk of revision for PJI (p = 0.118) when compared with CoP (hazard ratio [HR], 1.31; 95% confidence interval [CI], 0.50-3.41), MoP (HR, 2.10; CI, 0.91-4.82), and MoM (HR, 2.04; CI, 0.69-6.09). When the whole observation period was considered, CoC hips were associated with a lower risk of revision for deep infection when compared with CoP (HR, 1.30; CI, 0.78-2.18; p = 0.01), MoP (HR, 1.75; CI, 1.07-2.86; p = 0.02), and MoM (HR, 2.12; CI, 1.23-3.65; p = 0.008).
CONCLUSIONS: Our finding associating CoC THA bearings with a lower risk of infection after THA must be considered very preliminary, and we caution readers against attributing all of the observed difference to the bearing surface. It is possible that some or all of the observed difference associated with bearing type may have been driven by other factors such as ASA and BMI, which could not be included in our multivariate analysis, and so future registry studies on this topic must assess those variables carefully. LEVEL OF EVIDENCE: Level III, therapeutic study.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27249955      PMCID: PMC5014814          DOI: 10.1007/s11999-016-4916-y

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  16 in total

1.  Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles.

Authors:  H G Willert; H Bertram; G H Buchhorn
Journal:  Clin Orthop Relat Res       Date:  1990-09       Impact factor: 4.176

2.  Proceedings of the International Consensus on Periprosthetic Joint Infection.

Authors:  J Parvizi; T Gehrke; A F Chen
Journal:  Bone Joint J       Date:  2013-11       Impact factor: 5.082

3.  Ceramic-ceramic and metal-polyethylene total hip replacements: comparison of pseudomembranes after loosening.

Authors:  S Lerouge; O Huk; L Yahia; J Witvoet; L Sedel
Journal:  J Bone Joint Surg Br       Date:  1997-01

4.  Is tantalum protective against infection in revision total hip arthroplasty?

Authors:  A T Tokarski; T A Novack; J Parvizi
Journal:  Bone Joint J       Date:  2015-01       Impact factor: 5.082

5.  Clinical faceoff: Ceramic-on-ceramic THA: do the advantages outweigh the limitations?

Authors:  Laurent Sedel; William L Walter; Rocco P Pitto
Journal:  Clin Orthop Relat Res       Date:  2014-05-13       Impact factor: 4.176

Review 6.  The use of dense alumina-alumina ceramic combination in total hip replacement.

Authors:  P Boutin; P Christel; J M Dorlot; A Meunier; A de Roquancourt; D Blanquaert; S Herman; L Sedel; J Witvoet
Journal:  J Biomed Mater Res       Date:  1988-12

7.  Comparative effectiveness of metal-on-metal and metal-on-polyethylene bearings in Medicare total hip arthroplasty patients.

Authors:  Kevin J Bozic; Edmund C Lau; Kevin L Ong; Thomas P Vail; Harry E Rubash; Daniel J Berry
Journal:  J Arthroplasty       Date:  2012-05-17       Impact factor: 4.757

8.  Two- to 9-year clinical results of alumina ceramic-on-ceramic THA.

Authors:  Stephen B Murphy; Timo M Ecker; Moritz Tannast
Journal:  Clin Orthop Relat Res       Date:  2006-12       Impact factor: 4.176

9.  Periprosthetic tissues from third generation alumina-on-alumina total hip arthroplasties.

Authors:  Christina Esposito; Fiona Maclean; Pat Campbell; William L Walter; William K Walter; S Fiona Bonar
Journal:  J Arthroplasty       Date:  2013-03-13       Impact factor: 4.757

10.  Prostaglandin E2 level in tissue surrounding aseptic failed total hips. Effects of materials.

Authors:  L Sedel; J Simeon; A Meunier; J M Villette; S M Launay
Journal:  Arch Orthop Trauma Surg       Date:  1992       Impact factor: 3.067

View more
  8 in total

1.  The influence of bearing surfaces on periprosthetic hip infections: analysis of thirty nine thousand, two hundred and six  cementless total hip arthroplasties.

Authors:  Barbara Bordini; Susanna Stea; Francesco Castagnini; Luca Busanelli; Federico Giardina; Aldo Toni
Journal:  Int Orthop       Date:  2018-08-11       Impact factor: 3.075

2.  Clinical Faceoff: Instability After THA: The Potential Role of the Bearing Surface.

Authors:  Javad Parvizi; Laurent Sedel; Michael J Dunbar
Journal:  Clin Orthop Relat Res       Date:  2018-04       Impact factor: 4.176

3.  Cemented prosthesis as spacer for two-stage revision of infected hip prostheses: a similar infection remission rate and a lower complication rate.

Authors:  Wenming Zhang; Xinyu Fang; Tengbin Shi; Yuanqing Cai; Zida Huang; Chaofan Zhang; Jianhua Lin; Wenbo Li
Journal:  Bone Joint Res       Date:  2020-08-02       Impact factor: 5.853

Review 4.  Prevention of Periprosthetic Joint Infection (PJI): A Clinical Practice Protocol in High-Risk Patients.

Authors:  Ferdinando Iannotti; Paolo Prati; Andrea Fidanza; Raffaele Iorio; Andrea Ferretti; Daniel Pèrez Prieto; Nanne Kort; Bruno Violante; Gennaro Pipino; Alfredo Schiavone Panni; Michael Hirschmann; Marco Mugnaini; Pier Francesco Indelli
Journal:  Trop Med Infect Dis       Date:  2020-12-11

5.  Evaluation of temperature of a full ceramic total knee arthroplasty during MRI examinations.

Authors:  Klemens Trieb; Andreas Artmann; Michael Krupa; Sasch Senck; Franz Landauer
Journal:  Medicine (Baltimore)       Date:  2022-09-30       Impact factor: 1.817

Review 6.  Implant materials and prosthetic joint infection: the battle with the biofilm.

Authors:  Donald J Davidson; David Spratt; Alexander D Liddle
Journal:  EFORT Open Rev       Date:  2019-11-05

7.  Ceramic-on-Ceramic Bearing in Total Hip Arthroplasty Reduces the Risk for Revision for Periprosthetic Joint Infection Compared to Ceramic-on-Polyethylene: A Matched Analysis of 118,753 Cementless THA Based on the German Arthroplasty Registry.

Authors:  Lisa Renner; Carsten Perka; Oliver Melsheimer; Alexander Grimberg; Volkmar Jansson; Arnd Steinbrück
Journal:  J Clin Med       Date:  2021-03-12       Impact factor: 4.241

8.  Risk factors for prosthetic joint infections following total hip arthroplasty based on 33,337 hips in the Finnish Arthroplasty Register from 2014 to 2018.

Authors:  Valtteri J Panula; Kasperi J Alakylä; Mikko S Venäläinen; Jaason J Haapakoski; Antti P Eskelinen; Mikko J Manninen; Jukka S Kettunen; Ari-Pekka Puhto; Anna I Vasara; Laura L Elo; Keijo T Mäkelä
Journal:  Acta Orthop       Date:  2021-07-01       Impact factor: 3.717

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.