| Literature DB >> 30697086 |
Jennifer M Charlesworth1,2, Myriam A Davidson2.
Abstract
BACKGROUND: Emergency room physicians are frequently called upon to assess eye injuries and vision problems in the absence of specialized ophthalmologic equipment. Technological applications that can be used on mobile devices are only now becoming available.Entities:
Keywords: epidemiology; methodology; ocular; ophthalmology; visual acuity and emergency medicine; visual assessment
Year: 2019 PMID: 30697086 PMCID: PMC6339640 DOI: 10.2147/MDER.S186529
Source DB: PubMed Journal: Med Devices (Auckl) ISSN: 1179-1470
Figure 1Identification of relevant smartphone studies.
Figure 2Selection of Canadian smartphone applications.
Results of systematic application review, Canada (n= 24)
| App Name | Provider | Cost ($) | Store | Explicitly specifies which HCP | For Whom | Explicitly mention validated | How | Disclaimer present | Disclaimer (up to 44 words) |
|---|---|---|---|---|---|---|---|---|---|
| AmblyoCare | RISC Schware Grmbh | Free | Google Play | Yes | Ophthalmologists, orthoptists, ESIT specialists, pediatrists, neurologists, medical specialists | No | n/a | Yes | “the software may only be used in those European countries where one or both of these [English or German] languages is defined as an official language” |
| AmblyopiaVA | Manuel Rodriguez Vallejo | 21.99 (iTunes) 26.78 (Google Play) | Both | Yes | Optometry and ophthalmology practice | No | n/a | No | n/a |
| ClinicCSF | Manuel Rodriguez Vallejo | 59.99 | iTunes | Yes | Optometrists and ophthalmologists | Yes | measured the chromatic characteristics of the devices [ computers or portable devices such as Tablets or iPad] with the Spyder4Elite Colorimeter | Yes | For tablets, not for use on smartphones |
| Eye Chart HD - Screen Vision with Pocket Snellen, Sloan, Near Vision, and Amsler Grid Test | Dok LLC | Free | iTunes | No | “Triage, house visits, patients who have memorized the office chart” selected as implied HCP | No | n/a | Yes | “Should not be used as a primary visual acuity measuring tool, it can provide a handy rough vision screen when a chart is not available, or it can be used to complement static, wall- based Snellen charts.” |
| Eye Chart Premium | Dok LLC | 39.99 | iTunes | No | “Triage and hospital bedside, testing patients who have memorized the office chart” selected as implied HCP | No | n/a | Yes | “Should not be used as a primary visual acuity measuring tool, it can provide a handy rough vision screen when a chart is not available, or it can be used to complement static, wall-based Snellen charts.” |
| Eye Chart Pro Test Vision and Visual Acuity better with Snellen, Sloan, ETDRS, and Near Vision! | Dok LLC | Free | iTunes | No | “Triage, house visits, patients who have memorized the office chart” selected as implied HCP | No | n/a | Yes | “Eye Test Pro should not be used as a primary visual acuity measuring tool, it can provide a handy rough vision screen when a chart is not available, or it can be used to complement static, wall-based Snellen charts.” |
| Eye Chart Professional | Dok LLC | 139.99 | iTunes | No | “House visits, hospital bedside testing, or mounted to a wall” Selected as implied HCP | No | n/a | No | n/a |
| Eye Emergency Manual | Agency for Clinical Innovation | Free (both iTunes and Google Play) | Both | Yes | Medical, nursing, and allied health clinicians in Emergency Departments across New South Wales | No | n/a | Yes | “These guidelines have not undergone a formal process of evidence based clinical practice guideline development however they are the result of consensus opinion determined by the expert clinician working group” |
| Eye Handbook | Cloud Nine Developer | Free (both iTunes and Google Play) | Both | No | “Anyone involved in eye care” selected as implied HCP | No | n/a | No | n/a |
| EyeTest Droid | George YX Kong | Free | Google Play | Yes | General practitioners, ophthalmologists, optometrists, opticians, and medical and optometry students | No | n/a | Yes | “Note eyeTests is not a substitute for a full ophthalmic examination by an optometrist of ophthalmologist” |
| EyeTestsFree | George Kong Software | Free | iTunes | Yes | General practitioners, ophthalmologists, optometrists, opticians, and medical and optometry students | No | n/a | Yes | “Note eyeTests is not a substitute for a full ophthalmic examination by an optometrist of ophthalmologist” |
| EyeTests Easy | George Kong Software | Free | iTunes | Yes | General practitioners, ophthalmologists, optometrists, opticians, and medical and optometry students | No | n/a | Yes | “Note eyeTests is not a substitute for a full ophthalmic examination by an optometrist of ophthalmologist” |
| Morphision | Constantin Chifor | Free | iTunes | Yes | Ophthalmic professionals | No | n/a | No | n/a |
| NEOD Acuity | NEOD Inc. | 209.99 | iTunes | Yes | Vision care specialists | No | n/a | No | n/a |
| OKN+ | Medical | 3.99 | iTunes | Yes | Healthcare professionals | No | n/a | No | n/a |
| OphthDocs Eye App | Sheng Chiong Hong | Free | iTunes | Yes | Healthcare providers, ophthalmologists and optometrists | Yes | by ophthalmologist. For more information visit | No | Website no longer exists |
| Pocket Eye Exam | Nomad | 2.79 (iTunes) Free (Google Play) | Both | Yes | Neuro-ophthalmologists, neurologists, optometrist, medical school students and residents | Yes | Updated for Android 4.0 devices. Not tested for 5.0+. Tested on HDPI screen (Samsung Captivate) and works. MDPI and LDPI screens do not display Snell and Pupil Chart correctly. | No | n/a |
| Professional Clinical | Ossibus Software | 26.52 | Google Play | Yes | Optometrists, ophthalmologists, neurologists, medical doctors, optometric technicians, nurses, EMTs, medical assistants, and other healthcare providers | No | n/a | Yes | “These tools are very useful for screening purposes, but are not necessarily recommended for diagnosis” …”This app is intended for informational purposes only and not for the diagnosis, treatment, or cure of any medical conditions or illness.” “…” |
| Random Eye Chart Generator | Dok LLC | 2.79 | iTunes | No | “Triage, house visits, patients who have memorized the office chart” selected as implied HCP | No | n/a | Yes | “Should not be used as a primary visual acuity measuring tool, it can provide a handy rough vision screen when a chart is not available, or it can be used to complement static, wall-based Snellen charts.” |
| MultiQuity | Sightrisk | Free | iTunes | Yes | Eye care professionals | No | n/a | Yes | “The results and interpreation [sic] of the multiQuity suite are to be entrusted to eyecare professionals only” |
| Smart Optometry | Smart Optometry | 9.99 | iTunes | Yes | Eye-care practitioners | No | n/a | No | “Precise: Eye testing and screening oftern [sic] requires eye-care professionals to make calculations - giving the room for error. Eliminate this risk with precise calculations done by our Smart Optometry application. Our test are as precise if not more than the currently use on-the-wall testing equipment” |
| Smart Optometry Lite | Smart Optometry | Free | iTunes | Yes | Eye-care practitioners | No | n/a | No | “Precise: Eye testing and screening oftern [sic] requires eye-care professionals to make calculations - giving the room for error. Eliminate this risk with precise calculations done by our Smart Optometry application. Our test are as precise if not more than the currently use on-the-wall testing equipment” |
| Visual Acuity XL | Kybervision Japan LLC | 69.99 | iTunes | Yes | Vision care specialists | Yes | “Validated by a study from the University of Auckland, “An assessment of the iPad as a testing platform for distance visual acuity in adults” published in BMJ Open, June 2013” | Yes | “This app has not been validated yet on ipad [sic] mini with retina display” |
| VisualFields easy | George Kong Software | Free | iTunes | Yes | Clinicians in clinic or bed-side | No | n/a | Yes | “This app is not designed to substitute formal visual fields testing by optometrists or opthalmologists [sic]. Not all abnormalities found on visual fields test indicate an actual problem. This App does not provide formal interpretation of visual fields” |
Results of systematic application review, Ireland (n= 24)
| App Name | Provider | Cost ($) | Store | Explicitly specifies which HCP | For Whom | Explicitly mention validated | How | Disclaimer present | Disclaimer |
|---|---|---|---|---|---|---|---|---|---|
| AmblyoCare | RISC Software GmbH | Free | Google Play | Yes | ophthalmologists, orthoptists, ESIT specialists, pediatrists, neurologists, medical specialists, and affected people under medical guidance | No | n/a | No | n/a |
| AmblyopiaVA | Manuel Rodriguez Vallejo | 21.99 (iTunes) 23.27 (Google Play) | Both | Yes | Optometrist and Ophthalmologists | No | n/a | No | n/a |
| AMD Pro, A Metamorphopsia Det. | app4eyes | 69 | Google Play | Yes | Ophthalmologists, optometrists, opticians | No | n/a | No | n/a |
| AMD, A Metamorphopsia Detector | app4eyes | Free | Google Play | Yes | Ophthalmologists, optometrists, opticians | No | n/a | No | n/a |
| Central Vision Test | healthcare- 4mobile | Free | Google Play | Yes | implied mobile HCP | No | n/a | yes | “this application is not intended to replace optician’s regular full examination. We recommend you get a full eye test after using it”. |
| Eye Chart HD Screen Vision with Pocket Snellen, Sloan, Near Vision, and Amsler Grid Test | Dok LLC | Free | iTunes | Yes | Eye Care Professionals | No | n/a | Yes | “Though this unique, pocket-sized randomizable eye chart should not be used as primary visual acuity measuring tool, it can provide a handy rough vision screen when a chart is not available, or it can be used to complement static, wall based Snellen charts”. |
| Eye Chart Premium | Dok LLC | 29.99 | iTunes | Yes | Doctor or Nurse | No | n/a | Yes | “Though this unique, notebook-sized randomizable eye chart should not be used as primary visual acuity measuring tool, it can provide a handy rough vision screen when a chart is not available, or it can be used to complement static, wall-based Snellen charts”. |
| Eye Emergency Manual | Agency for Clinical Innovation | Free (iTunes and Google Play) | Both | Yes | All medical, nursing, and allied health clinicians in emergency departments across New South Wales | No | n/a | No | n/a |
| Eye Handbook | Cloud Nine Development LLC | Free (iTunes and Google Play) | Both | Yes | iTunes: Eye Care Professionals Google Play: For anyone involved in eye care. Note: top of description states the following “Complete overhaul of previous design. Extensive reconstruction of form and function. Now available on Android Tablet!” | No | n/a | No | n/a |
| eyeTests Easy | George Kong Softwares | Free | iTunes | Yes | Eye care clinicians including general practitioners, ophthalmologies [sic], optometrists, opticians, medical and optometry students | No | n/a | Yes | Note: EyeTests is not a substitute for full ophthalmic examination by an optometrist pr [sic] ophthalmologist |
| eyeTestsDroid | George YX Kong | Free | Google Play | Yes | general practitioners, ophthalmologists, optometrists, opticians, medical and optometry students | No | n/a | Yes | Note eyeTests is not a substitute for a full ophthalmic examination by an optometrist or ophthalmologist. |
| LogMar Snellen | Hilmi Software | 15.65 | Google Play | Yes | Doctor or Nurse | No | n/a | No | n/a |
| Medmont AT20P | Medmont Australia PT | Free | Google Play | No | “people with patients” Implied HCP | No | n/a | No | n/a |
| Optical Tool | Brent McCardle | 2.99 | iTunes | Yes | Optometric office, optometrist, and opticians | No | n/a | No | n/a |
| Optician | familion.ru | Free | Google Play | Yes | students, nurses, and doctors | No | n/a | Yes | please note that these tools provided in this app are used at your own risk and we do not make any claim as to their effectiveness as a testing tool. You should always seek the advice of a trained professional where possible. |
| Pocket Eye Exam | Nomad | 1.99 (iTunes) 1.40 (Google Play) | Both | Yes | Neuro-ophthalmologist, neurologists, optometrists, medical school students and residents | No | n/a | Yes | No disclaimer for iTunes. Google Play (after overhaul) : Tested on HDPI screen (Samsung Captivate) and works, MDPI and LDPI screens do not display Snellen and pupil chart correctly. Updated Android 4.0 devices, not tested for 5.0+ |
| Pocket Ophthalmology | centricweb.co.uk | Free | Google Play | No | “This app aims to discuss treatment protocols, tests, and induction guides followed by a tertiary ophalmology [sic] clinic in the UK” Implied HCP | No | n/a | No | n/a |
| Professional Clinic | Ossibus Software | 27.99 | Google Play | Yes | optometrists, ophthalmologists, neurologists, medical doctors, optometric technicians, nurses, EMTs, medical assistants, and other healthcare providers | No | n/a | Yes | This app is intended for informational purposts [sic] only and not for the diagnosis, treatment, or cure of any medical condition or illness. The app should not be used as a substitute for professional medical care or interpretation. Ossibus Software and its writers are not responsible or liable for the use or misuse of the information contained in this app. |
| Random Eye Chart Generator | Dok LLC | 1.99 | iTunes | Yes | Eye Care Professionals | No | n/a | Yes | This unique, pocket-sized randomizable eye chart should not be used as primary visual acuity measuring tool, it can provide a handy rough vision screen when a chart is not available, or it can be used to complement static, wall based Snellen charts. |
| Smart Optometry | Smart Optometry | 4.99 | iTunes | Yes | Eye Care Professionals | No | n/a | No | n/a |
| StereoTAB | Manuel Rodriguez Vallejo | 19.99 | iTunes | Yes | Optometric and Ophthalmology practice | No | n/a | No | n/a |
| Vision Tests (Complete Package) | Manuel Rodriguez Vallejo | 94.99 | iTunes | Yes | Optometrist and Ophthalmologists | Yes | “gold standards or current vision tests”. Indicates that further information is available on developer website. However, link from iTunes website not | No | n/a |
| Visual Acuity XL | Kybervision Japan LLC | 49.99 | iTunes | Yes | Vision Care Specialists | Yes | Peer Reviewed Journal (BMJ Open, June 2013) | No | n/a |
| visualFields easy | George Kong Softwares | Free | iTunes | Yes | Clinicians | No | n/a | Yes | This app is not designed to substitute formal visual fields testing by optometrists of ophthalmologists. Not all abnormalities found on VisualFields test indicate an actual problem. This app does not provide formal interpretation of visual fields. Fixation losses are not tracked in this version of the app. |
Abbreviations: ESIT, early support for infants and toddlers; HCP, health care professional; EMTs, emergency medical technicians; HDPI, high dots per inch; MDPI, medium DPI; LDPI, low DPI; NA, not applicable.
Figure 3Selection of Irish smartphone applications.
Figure 4Cost of Canadian smartphone applications by platform.
Figure 5Cost of Irish smartphone applications by platform.
Quality assessment of selected apps
| Country | Provider | Vendor | Quality assessment | |
|---|---|---|---|---|
|
| ||||
| Both | RISC Software | Google Play | ||
| Canada only | Manuel Rodriguez Vallejo | Both | ||
| Both | Cloud Nine Developer | Both | ||
| Both | Nomad | Both | ||
| Both | KyberVision Japan | iTunes | ||
Note:
No measures of validation internal or external noted;
some discussion of internal validation or research noted;
partial peer or government validation.
Demographic data of articles identified in a systematic search of the health literature (n=12)
| Reference | Study Design | Subjects (n) | Results | Applications Reviewed, (n) | Methods of assessment (Validity/Reliability/Responsiveness to change) | Primary outcome | Conclusions | Limitations of paper |
|---|---|---|---|---|---|---|---|---|
| Aslam et al | Threshold testing - 4 phases (initial threshold, threshold, attention check, and final threshold) EDTRS (Landolt C) vs MAVERIC system: specialised software on a tablet computer, housed in a bespoke viewing booth | 78 | High contrast visual acuity measurements (normal): | 2 | Reliability Assessment Fixed distance of 40 cm | High and low contract visual acuity measures Versus EDTRS Landolt C | Reliable self-test VA with a high degree of reliability and agreement when compared vs gold standard chart based measurements. | The major limitation at present is screen resolution and this will inevitably improve with time. The ease of availability and mobility of components means that such devices could in future be used for home testing or testing in general practice settings and further studies are needed to confirm this. |
| Bastawrous et al | Validation Study | 300 older-aged Kenyan adults | • Test retest variability smart phone VA ±0.029logMAR (95% CI). | 3 | Variability test | Monocular logMAR visual acuity scores for each test: ETDRS chart logMAR, Snellen acuity, and Peek Acuity. | Peek Acuity smartphone test is capable of accurate and repeatable acuity measurements consistent with published data on the test-retest variability of acuities measured using 5-letter-per- line retro illuminated logMAR charts. | may not be generalizable to other populations. |
| Black et al | Blinded, diagnostic test study | 85 | • iPad tablet with its glossy screen significantly poorer (approximately 2 LogMAR lines) vs ETDRS chart and a standard computerised testing system (n=56) due to glare. | 2 | Comparison | Visual acuity measured under a number of conditions. | Tablets are only suitable for use measuring VA in situations where sources of glare can be eliminated. | • Technological advancement: higher resolution screens. |
| Brady et al | Validation Study in participants’ homes and temporary clinic settings in rural Kenya | 300 | • test-retest variability of smartphone acuity data were ±0.029 logMAR. | 3 | Comparison | • monocular logMAR visual acuity scores for: ETDRS chart logMAR, Snellen acuity, and Peek Acuity. | test-retest variability of peek smart phone visual acuity using 5-letter-per-line retro illuminated logMAR charts is consistent with published data. | Generalizability to western population |
| Chacon et al | Validation vs gold standard netbook display for color vision assessment in normal verus colour deficient subjects testing. | 32 16 Normal 16 Colour vision deficient. | Both displays showed 100% specificity for confirming CVN and 100% sensitivity for detecting CVD. In CVNs there was no difference between scores on netbook vs. tablet displays. G cone CVDs showed slightly lower G cone contrast test scores on the tablet. | None noted specifically | Validity: ability to discriminate on tablet known normal and deficient colour vision subjects. | • Sensitivity 100% | Construct validity shows that tablet can be used to discriminate colour vision normal versus colour vision deficient individuals | Not used as diagnostic test. Didn’t assess discrimination threshold. Did not address glare and distance. |
| Cheng et al | Systematic review of the The Apple iTunes store was searched for iPhone eye care–themed apps | None | In total, 182 apps were identified. The majority of apps lacked community user ratings and had 3,000 or fewer downloads (84% and 69%, respectively). Consistent with other medical specialties, only 37% of apps had documented qualified professional involvement in their development. When stratified by intended audience, 52% and 44% of apps designed for ophthalmologists and optometrists, respectively, had professional input, compared with 31% for non–eye care clinicians and 21% for the general public. | 182 | None | Description of applications available | • rapid emergence of eye care apps. But a low level of qualified professional involvement in app development and a lack of peer review after publishing remain. | Single store, no accompanying literature analysis. |
| Kollbaum et al | Validation of an iPad-based letter contrast sensitivity test versus 2 tests including gold standard for clinical contrast sensitivity paper based measure (Pilli- Robson test) and computer based Freiburg (variable contrast Landolt C presented at eight possible orientations and used a 30-trial Best PEST procedure) | • N=40 | Test retest 95% LoA: iPad =T0.19, Pelli-Robson = T0.19 Freiburg =T0.15. The iPad test showed good agreement with the Freiburg test with similar mean (STD) logCS (iPad = 1.98-0.11, Freiburg = 1.96T0.06); 95% LoA (T0.24), iPad vs. Pelli-Robson had lower values (1.65T0.04). Low-vision subjects (iPad =T0.24, Pelli-Robson = T0.23, Freiburg =T0.21). Agreement between the iPad and Freiburg tests was good (iPad = 1.45T0.40, Freiburg = 1.54T0.37), but the Pelli-Robsontest gave significantly lower values (1.30T0.30). | 1 | • Ipad good precision (test retest) and good agreement with two test | • Precision | • iPad test showed good precision | The newly developed application. Did not test visual acuity. |
| Perera et al | • Review of Snellen equivalent for optotype size. | 88 | • logMAR of mean difference in visual acuity iphont versus paper was 0.02 logMAR (95% limit of agreement −0.332, 0.372 logMAR). | 11 | Validity | LogMAR/Snellen equivalent VA | • Eye phone apps could not validly discriminate Snellen visual acuity within one line. | • Possible selection bias, as the right eye is more frequently the dominant eye and chosen tested eye. If ocular dominance was an important factor in the reading of the chart results may be influenced. |
| Phung et al | • Retrospective chart review reliability and validity | 126 | • SightBook, Snellen, and near card acuities had excellent test– retest reproducibility | 1 | Validity and Reliability | • Acuities were converted to approximate ETDRS letters for statistical purposes | • The discrepancy between SightBook mobile app and the clinic charts acuities are large; however, the results are highly reproducible. | • Small sample size – |
| Tofigh et al | Cross sectional comparison of near visual acuity. | 100 | • Eye Hand Book application overestimates the near VA vs. conventional near vision card by an average of 0.11 LogMAR (P-value of 0.0001) | 1 | Validity and Reliability | Near LogMAR Visual acuity | • Potential disparity in VA measurement between different platforms. | • Currently out-dated technology |
| Toner et al | • Prospective cohort: Validity and Reliability study in children age 6-18 years | 73 | • strong linear correlation (r50.92) | • 2 | • Test-retest reliability and validity | • Monocular visual acuity testing using the subject’s poorer-seeing eye | The mobile application is a valid and reliable test of VA in children aged 6–18 years compared with its paper counterpart | Not randomized test order Not for poor vision children |
| Zhang et al | Prospective Cohort: Validation study | 120 (consecutive eyes) | • mean difference (bias) of 0.02 logMAR units between the VA results from the iPad chart and the light-box chart | 2 | Validity | Snellen VA | • Good agreement in patients with better VA (i.e. Snellen VA better than 20/200) | • Visual charts with Snellen notations were compared. Snellen visual charts are not in logMAR steps. |
Abbreviations: EDTRS, Early Treatment Diabetic Retinopathy Study; VA, visual acuity; MAR, minimum angle of resolution; LoA, limit of agreement; STD, standard deviation.