Literature DB >> 30688093

Range of Motion Measurements of the Fingers Via Smartphone Photography.

John Z Zhao1, Philip E Blazar1, Ariana N Mora1, Brandon E Earp1.   

Abstract

Background: Range of motion (ROM) measurements of the fingers are frequently obtained during hand physical examinations. While traditionally measured by manual goniometry, smartphone photography introduces an alternative method of ROM measurement that also has potential telemedicine applications. The purpose of this study was to evaluate the reliability of smartphone photography measurements as an alternative to traditional goniometry, using the patient with Dupuytren disease as a model.
Methods: Patients with a confirmed Dupuytren contracture were prospectively enrolled in this study. Range of motion measurements of the affected joints were obtained prior to any invasive treatments. Two sets of photographs were taken by both a clinical staff member and a nonclinical individual unaffiliated with the study. Both sets of photos were analyzed for degree of contracture via software analysis and compared against traditional goniometer measurements.
Results: The study prospectively enrolled 50 consecutive patients with Dupuytren disease, comprising 123 affected joints. The mean contractures of all affected joints as measured by manual goniometry, trained photograph goniometry, and untrained photograph goniometry were 38.5, 35.3, and 35.5, respectively. The mean difference in contracture measurement was 3.2° between manual and trained photograph goniometry and 3.0° between manual and untrained photograph goniometry. There was no statistically significant difference between trained and untrained photo set measurements. Photograph measurements between separate raters demonstrated high consistency (intraclass correlation coefficient = 0.92). Conclusions: Smartphone photography provides contracture measurements equivalent to the accepted error of a finger goniometer (3.2° compared with 5°). The accuracy of smartphone photography in measuring contractures offers potential telemedicine applications for both clinical and research needs.

Entities:  

Keywords:  Dupuytren; contracture; range of motion; smartphone photography; telemedicine

Year:  2019        PMID: 30688093      PMCID: PMC7543212          DOI: 10.1177/1558944718820955

Source DB:  PubMed          Journal:  Hand (N Y)        ISSN: 1558-9447


  21 in total

1.  Lateral digital photography with computer-aided goniometry versus standard goniometry for recording finger joint angles.

Authors:  G A Georgeu; S Mayfield; A M Logan
Journal:  J Hand Surg Br       Date:  2002-04

2.  Joint angle measurement: a comparative study of the reliability of goniometry and wire tracing for the hand.

Authors:  B Ellis; A Bruton; J R Goddard
Journal:  Clin Rehabil       Date:  1997-11       Impact factor: 3.477

3.  Reliability and concurrent validity of knee angle measurement: smart phone app versus universal goniometer used by experienced and novice clinicians.

Authors:  Steven Milanese; Susan Gordon; Petra Buettner; Carol Flavell; Sally Ruston; Damien Coe; William O'Sullivan; Steven McCormack
Journal:  Man Ther       Date:  2014-06-04

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Reliability of goniometric measurements.

Authors:  D C Boone; S P Azen; C M Lin; C Spence; C Baron; L Lee
Journal:  Phys Ther       Date:  1978-11

6.  Developing criteria for establishing interrater reliability of specific items: applications to assessment of adaptive behavior.

Authors:  D V Cicchetti; S A Sparrow
Journal:  Am J Ment Defic       Date:  1981-09

7.  Reliability and validity of goniometric iPhone applications for the assessment of active shoulder external rotation.

Authors:  Katy Mitchell; Simran Bakshi Gutierrez; Stacy Sutton; Stephanie Morton; Andrea Morgenthaler
Journal:  Physiother Theory Pract       Date:  2014-03-21       Impact factor: 2.279

8.  Policy recommendations to guide the use of telemedicine in primary care settings: an American College of Physicians position paper.

Authors:  Hilary Daniel; Lois Snyder Sulmasy
Journal:  Ann Intern Med       Date:  2015-09-08       Impact factor: 25.391

9.  Reliability and criterion validity of two applications of the iPhone™ to measure cervical range of motion in healthy participants.

Authors:  Yannick Tousignant-Laflamme; Nicolas Boutin; Alexandre M Dion; Carol-Anne Vallée
Journal:  J Neuroeng Rehabil       Date:  2013-07-05       Impact factor: 4.262

10.  Reliability of the standard goniometry and diagrammatic recording of finger joint angles: a comparative study with healthy subjects and non-professional raters.

Authors:  Valdas Macionis
Journal:  BMC Musculoskelet Disord       Date:  2013-01-09       Impact factor: 2.362

View more
  5 in total

1.  [Accuracy of key point matrix technology based contactless automatic measurement for joint motion of hand].

Authors:  Lulu Lü; Jiantao Yang; Fanbin Gu; Jingyuan Fan; Chaoyang Wang; Qingtang Zhu; Xiaolin Liu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-05-15

2.  Adoption of Telemedicine: A Debrief for the Orthopedic Practitioner.

Authors:  Karim A Shafi; Katherine Fortson; Sravisht Iyer
Journal:  HSS J       Date:  2021-02-21

3.  Examining the Hand in the Video Consultation.

Authors:  Kristian Welle; Stefan Täger; Roslind Karolina Hackenberg; Alexander Markowetz; Frank Alexander Schildberg; Christof Burger; Dieter Christian Wirtz; Tom Jansen; Koroush Kabir
Journal:  Z Orthop Unfall       Date:  2021-01-21       Impact factor: 0.923

4.  Telemedicine in orthopaedics during COVID-19 and beyond: A systematic review.

Authors:  Zakir Haider; Bashaar Aweid; Padmanabhan Subramanian; Farhad Iranpour
Journal:  J Telemed Telecare       Date:  2020-08-06       Impact factor: 6.344

5.  Validation of Teleconference-based Goniometry for Measuring Elbow Joint Range of Motion.

Authors:  Paul A Dent; Benjamin Wilke; Sarvram Terkonda; Ian Luther; Glenn G Shi
Journal:  Cureus       Date:  2020-02-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.