Literature DB >> 3084548

Clinical comparison of a new automated infrared blood culture system with the BACTEC 460 system.

D Jungkind, J Millan, S Allen, J Dyke, E Hill.   

Abstract

A new blood culture instrument, the BACTEC (Johnston Laboratories, Inc., Towson, Md.) NR-660, which utilizes infrared detection of carbon dioxide from microbial metabolism, was compared with the radiometric BACTEC 460 system. There were 1,554 isolates from 18,785 paired aerobic blood cultures. Of these isolates, 1,303 were isolated from the radiometric 6B medium, and 1,259 were isolated from the NR6A medium (P = 0.06). Analysis of the data indicated no significant differences in recovery when any individual species was considered. When organisms were considered as groups, there were no significant detection differences for gram-negative bacilli, yeasts, or anaerobes. For gram-positive cocci in aerobic medium, the BACTEC 460 detected 84.3% of the total isolates, and the BACTEC NR-660 detected 79.7% (P = 0.04). There were 891 isolates from 13,983 paired anaerobic blood cultures. Of these isolates, 725 were recovered from the radiometric 7D BACTEC medium, and 723 were recovered from the NR7A BACTEC medium (P greater than 0.9). In the anaerobic media there was no significant difference in detection of any organism group, including the gram-positive cocci. When the results of the aerobic and anaerobic media were combined, there was equivalence between the two systems for the detection of gram-positive cocci (P greater than 0.2) and other organism groups. When the ability to detect septic episodes was compared, there was no significant difference for any organism group (P = 0.12). For aerobic media, the mean times for detection were 30.5 and 29.5 h for the BACTEC 460 and NR-660, respectively. For anaerobic media, the mean times for detection were 39.8 and 41.6 h for the BACTEC 460 NR-660, respectively. Compared with the BACTEC 460, the BACTEC NR-660 system had a greater ease of operation, faster test cycle, computerized data base, and equally rapid detection of positive cultures.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3084548      PMCID: PMC268624          DOI: 10.1128/jcm.23.2.262-266.1986

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  6 in total

1.  Effect of blood dilution on recovery of organisms from clinical blood cultures in medium containing sodium polyanethol sulfonate.

Authors:  J F Salventi; T A Davies; E L Randall; S Whitaker; J R Waters
Journal:  J Clin Microbiol       Date:  1979-02       Impact factor: 5.948

Review 2.  The laboratory approach to the detection of bacteremia.

Authors:  R C Tilton
Journal:  Annu Rev Microbiol       Date:  1982       Impact factor: 15.500

3.  The importance of volume of blood cultured in the detection of bacteremia and fungemia.

Authors:  D M Ilstrup; J A Washington
Journal:  Diagn Microbiol Infect Dis       Date:  1983-06       Impact factor: 2.803

4.  Pseudobacteremia.

Authors:  J F John; E R Bannister
Journal:  Infect Control       Date:  1984-02

5.  Automated radiometric detection of bacteria in 2,967 blood cultures.

Authors:  H J DeBlanc; F DeLand; H N Wagner
Journal:  Appl Microbiol       Date:  1971-11

6.  Controlled evaluation of the volume of blood cultured in detection of bacteremia and fungemia.

Authors:  J H Tenney; L B Reller; S Mirrett; W L Wang; M P Weinstein
Journal:  J Clin Microbiol       Date:  1982-04       Impact factor: 5.948

  6 in total
  21 in total

Review 1.  Update on detection of bacteremia and fungemia.

Authors:  L G Reimer; M L Wilson; M P Weinstein
Journal:  Clin Microbiol Rev       Date:  1997-07       Impact factor: 26.132

2.  Comparison of Sentinel and Bactec blood culture systems.

Authors:  M Stevens; H Patel; A Walters; K Burch; A Jay; N Dowling; C J Mitchell; R A Swann; A T Willis; D C Shanson
Journal:  J Clin Pathol       Date:  1992-09       Impact factor: 3.411

3.  Assessment of the BACTEC NR660 blood culture system for the detection of bacteremia in young children.

Authors:  J D Anderson; C Trombley; N Cimolai
Journal:  J Clin Microbiol       Date:  1989-04       Impact factor: 5.948

4.  Detection of bacterial growth by gas absorption.

Authors:  J R Waters
Journal:  J Clin Microbiol       Date:  1992-05       Impact factor: 5.948

5.  Determination of growth value thresholds for BACTEC PLUS aerobic blood culture vials.

Authors:  J E McGowan; B G Metchock
Journal:  J Clin Microbiol       Date:  1992-04       Impact factor: 5.948

Review 6.  Bacteraemia in man and animals: an overview.

Authors:  J Vaid
Journal:  Vet Res Commun       Date:  1991       Impact factor: 2.459

7.  Rapid detection of positive blood cultures with the BACTEC NR-660 does not require first-day subculturing.

Authors:  M H Levi; P Gialanella; M R Motyl; J C McKitrick
Journal:  J Clin Microbiol       Date:  1988-11       Impact factor: 5.948

Review 8.  Detection of bloodstream infections in children.

Authors:  J M Campos
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-09       Impact factor: 3.267

9.  Comparative evaluation of nonradiometric BACTEC and improved oxoid signal blood culture systems in a clinical laboratory.

Authors:  C Daley; I Lim; J Modra; I Wilkinson
Journal:  J Clin Microbiol       Date:  1990-07       Impact factor: 5.948

10.  Routine evaluation of BACTEC NR-16A and NR-17A media.

Authors:  R J Courcol; A V Durocher; M Roussel-Delvallez; A Fruchart; G R Martin
Journal:  J Clin Microbiol       Date:  1988-09       Impact factor: 5.948

View more