Literature DB >> 6863507

Microbiological and clinical evaluation of the isolator lysis-centrifugation blood culture tube.

N K Henry, C A McLimans, A J Wright, R L Thompson, W R Wilson, J A Washington.   

Abstract

In a controlled evaluation of 6,010 blood cultures, the yield of clinically significant microorganisms was greater from a lysis-centrifugation system (Isolator, Du Pont Co.) than from a nonvented vacuum bottle containing tryptic soy broth with sodium polyanetholesulfonate and CO2 and a vented bottle containing biphasic brain heart infusion medium with sodium polyanetholesulfonate. The Isolator significantly increased the frequency of isolation of Staphylococcus aureus and Candida spp. and significantly decreased the time required for the detection of S. aureus, Pseudomonas aeruginosa, and Candida spp.; however, anaerobic bacteria were recovered significantly more frequently from nonvented bottles with tryptic soy broth, and pneumococci were recovered significantly more frequently from both bottle systems. Contamination of cultures was significantly greater with the Isolator system than with either bottle system. Regardless of the number of blood cultures obtained per septic episode, the Isolator detected microbiologically proven bacteremia or fungemia in a significantly greater number of patients and significantly decreased the time required for detection.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6863507      PMCID: PMC272757          DOI: 10.1128/jcm.17.5.864-869.1983

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  4 in total

1.  Blood culture technique based on centrifugation: developmental phase.

Authors:  G L Dorn; J R Haynes; G G Burson
Journal:  J Clin Microbiol       Date:  1976-03       Impact factor: 5.948

2.  Improved blood culture technique based on centrifugation: clinical evaluation.

Authors:  G L Dorn; G A Land; G E Wilson
Journal:  J Clin Microbiol       Date:  1979-03       Impact factor: 5.948

3.  Lysis-filtration blood culture versus conventional blood culture in a bacteremic rabbit model.

Authors:  C H Zierdt; D L Peterson; J C Swan; J D MacLowry
Journal:  J Clin Microbiol       Date:  1982-01       Impact factor: 5.948

4.  Rapid diagnosis of bacteremia.

Authors:  S M Finegold; M L White; I Ziment; W R Winn
Journal:  Appl Microbiol       Date:  1969-09
  4 in total
  72 in total

1.  Relevance of the number of positive bottles in determining clinical significance of coagulase-negative staphylococci in blood cultures.

Authors:  S Mirrett; M P Weinstein; L G Reimer; M L Wilson; L B Reller
Journal:  J Clin Microbiol       Date:  2001-09       Impact factor: 5.948

2.  Use of PCR with universal primers and restriction endonuclease digestions for detection and identification of common bacterial pathogens in cerebrospinal fluid.

Authors:  J J Lu; C L Perng; S Y Lee; C C Wan
Journal:  J Clin Microbiol       Date:  2000-06       Impact factor: 5.948

3.  Nonvalue of antigen detection immunoassays for diagnosis of candidemia.

Authors:  P Phillips; A Dowd; P Jewesson; G Radigan; M G Tweeddale; A Clarke; I Geere; M Kelly
Journal:  J Clin Microbiol       Date:  1990-10       Impact factor: 5.948

4.  Effect of sample volume on yield of positive blood cultures from adult patients with haematological malignancy.

Authors:  D F Brown; R E Warren
Journal:  J Clin Pathol       Date:  1990-09       Impact factor: 3.411

5.  Detection of bacteria in blood by centrifugation and filtration.

Authors:  M Bernhardt; D R Pennell; L S Almer; R F Schell
Journal:  J Clin Microbiol       Date:  1991-03       Impact factor: 5.948

6.  Reduced PCR sensitivity due to impaired DNA recovery with the MagNA Pure LC total nucleic acid isolation kit.

Authors:  Tim Schuurman; Alex van Breda; Richard de Boer; Mirjam Kooistra-Smid; Marcel Beld; Paul Savelkoul; René Boom
Journal:  J Clin Microbiol       Date:  2005-09       Impact factor: 5.948

7.  Clinical correlations of serial quantitative blood cultures determined by lysis-centrifugation in patients with persistent septicemia.

Authors:  E Whimbey; B Wong; T E Kiehn; D Armstrong
Journal:  J Clin Microbiol       Date:  1984-06       Impact factor: 5.948

8.  Clinical laboratory comparison of the 10-ml isolator blood culture system with BACTEC radiometric blood culture media.

Authors:  J A Kellogg; J P Manzella; J H McConville
Journal:  J Clin Microbiol       Date:  1984-10       Impact factor: 5.948

9.  Importance of blood volume cultured in the detection of bacteremia.

Authors:  M Arpi; M W Bentzon; J Jensen; W Frederiksen
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-09       Impact factor: 3.267

10.  Continuous quality improvement for introduction of automated blood culture instrument.

Authors:  M Alfa; S Sanche; S Roman; Y Fiola; P Lenton; G Harding
Journal:  J Clin Microbiol       Date:  1995-05       Impact factor: 5.948

View more