Literature DB >> 3546365

Effect of agitation and frequent subculturing on recovery of aerobic and facultative pathogens by Roche Septi-Chek and BACTEC blood culture systems.

M J Kim, R L Gottschall, L D Schwabe, E L Randall.   

Abstract

The positivity rate and time to recovery of pathogens were compared in Roche Septi-Chek (RSC-TSB) and BACTEC radiometric systems on 3,539 paired blood cultures. Both systems were steadily agitated, with frequent subculturing or processing of the RSC-TSB agar slides and BACTEC bottles, respectively, during the first 24 h of incubation. The RSC-TSB system recovered 249 pathogens (7.0% positivity rate), compared with 234 (6.6% positivity rate) isolates recovered from BACTEC. For the most common isolates, Staphylococcus aureus and the Enterobacteriaceae, the median time to detection was 15.8 h for BACTEC and 18.6 h for the RSC-TSB system. No statistically significant difference was observed in recovery of organisms from the two systems, except for S. aureus (P less than 0.05). In the RSC-TSB system, 42% of S. aureus, 58% of the Enterobacteriaceae, and 45% of Pseudomonas aeruginosa isolates had sufficient growth on the agar slant to allow performance of rapid standardized identification and susceptibility studies. In comparison with other studies using static incubation, it appears that agitation and frequent subculturing of the RSC-TSB system during the first 24 h of incubation decreased the time to detection for the majority of significant blood culture isolates.

Entities:  

Mesh:

Year:  1987        PMID: 3546365      PMCID: PMC265890          DOI: 10.1128/jcm.25.2.312-315.1987

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  6 in total

1.  Comparison of the Roche Septi-Chek blood culture bottle with a brain heart infusion biphasic medium bottle and with a tryptic soy broth bottle.

Authors:  N K Henry; C M Grewell; C A McLimans; J A Washington
Journal:  J Clin Microbiol       Date:  1984-03       Impact factor: 5.948

2.  Comparison of lysis-centrifugation with a biphasic blood culture medium for the recovery of aerobic and facultatively anaerobic bacteria.

Authors:  N K Henry; C M Grewell; P E Van Grevenhof; D M Ilstrup; J A Washington
Journal:  J Clin Microbiol       Date:  1984-09       Impact factor: 5.948

3.  Comparison of a radiometric and a broth-slide system for aerobic blood culture.

Authors:  J A Smith; F J Roberts; J Ngui-Yen
Journal:  J Clin Microbiol       Date:  1983-07       Impact factor: 5.948

4.  Clinical laboratory comparison of a slide blood culture system with a conventional broth system.

Authors:  M A Pfaller; T K Sibley; L M Westfall; J E Hoppe-Bauer; M A Keating; P R Murray
Journal:  J Clin Microbiol       Date:  1982-09       Impact factor: 5.948

5.  Comparison of a slide blood culture system with a supplemented peptone broth culture method.

Authors:  L E Bryan
Journal:  J Clin Microbiol       Date:  1981-10       Impact factor: 5.948

6.  Controlled evaluation of the agar-slide and radiometric blood culture systems for the detection of bacteremia and fungemia.

Authors:  M P Weinstein; L B Reller; S Mirrett; C W Stratton; L G Reimer; W L Wang
Journal:  J Clin Microbiol       Date:  1986-02       Impact factor: 5.948

  6 in total
  10 in total

1.  Nonvalue of terminal aerobic subculture of unvented Roche Columbia broth blood culture bottles.

Authors:  P P Bourbeau; B J Heiter; D W Naumovitz
Journal:  J Clin Microbiol       Date:  1992-02       Impact factor: 5.948

2.  BacT/Alert: an automated colorimetric microbial detection system.

Authors:  T C Thorpe; M L Wilson; J E Turner; J L DiGuiseppi; M Willert; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1990-07       Impact factor: 5.948

3.  Assessment of the BACTEC NR660 blood culture system for the detection of bacteremia in young children.

Authors:  J D Anderson; C Trombley; N Cimolai
Journal:  J Clin Microbiol       Date:  1989-04       Impact factor: 5.948

4.  Methods used in the United Kingdom for the culture of micro-organisms from blood.

Authors:  D F Brown; S F Perry
Journal:  J Clin Pathol       Date:  1992-06       Impact factor: 3.411

5.  Biographical feature: Eileen L. Randall, Ph.D.

Authors:  Alexander J McAdam
Journal:  J Clin Microbiol       Date:  2013-08-28       Impact factor: 5.948

6.  Clinical comparison of the recoveries of bloodstream pathogens in Septi-Chek brain heart infusion broth with saponin, Septi-Chek tryptic soy broth, and the isolator lysis-centrifugation system.

Authors:  P R Murray; A W Spizzo; A C Niles
Journal:  J Clin Microbiol       Date:  1991-05       Impact factor: 5.948

7.  Comparative evaluation of the oxoid signal and Roche Septi-Chek blood culture systems.

Authors:  P R Murray; A C Niles; R L Heeren; M M Curren; L E James; J E Hoppe-Bauer
Journal:  J Clin Microbiol       Date:  1988-12       Impact factor: 5.948

8.  Critical assessment of blood culture techniques: analysis of recovery of obligate and facultative anaerobes, strict aerobic bacteria, and fungi in aerobic and anaerobic blood culture bottles.

Authors:  P R Murray; P Traynor; D Hopson
Journal:  J Clin Microbiol       Date:  1992-06       Impact factor: 5.948

9.  Comparison of the lysis-centrifugation and agitated biphasic blood culture systems for detection of fungemia.

Authors:  P R Murray
Journal:  J Clin Microbiol       Date:  1991-01       Impact factor: 5.948

10.  Effect of agitation and terminal subcultures on yield and speed of detection of the Oxoid Signal blood culture system versus the BACTEC radiometric system.

Authors:  M P Weinstein; S Mirrett; L G Reimer; L B Reller
Journal:  J Clin Microbiol       Date:  1989-03       Impact factor: 5.948

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.