Literature DB >> 30546613

Editorial: Trapped pacemaker lead extraction: Necessity, challenge, and beyond.

Toru Maruyama1,2, Keita Odashiro2.   

Abstract

Entities:  

Keywords:  Pacemaker-dependence; Pocket infection; Transvenous extraction; Trapped lead

Year:  2015        PMID: 30546613      PMCID: PMC6280685          DOI: 10.1016/j.jccase.2015.11.003

Source DB:  PubMed          Journal:  J Cardiol Cases        ISSN: 1878-5409


× No keyword cloud information.
The implantation rate of cardiac rhythm devices, such as permanent pacemakers and implantable cardioverter-defibrillators, has increased significantly over the past decades. Owing to this increase, there is a growing rate of transvenous lead extraction (TLE) due to lead failure, device infection, device upgrading, and lead or device recalls. However, TLE is a complex, invasive, and challenging procedure. The troubleshooting experience in operators and the multidisciplinary team formation are determinants of procedural outcome. The necessity of TLE is divided practically into two cases, i.e. case of device or pocket infection and that of non-infection. The circumstance of non-infection includes malfunctioning, upgrading, or recalled lead or device. Riata™ (St. Jude Medical, St. Paul, MN, USA) and Sprint Fidelis® (Medtronic Inc, Minneapolis, MN, USA) leads were recalled by the US Food and Drug Administration due to an increased rate of failure [1]. There is still a controversy concerning the management of failed, unnecessary, recalled, or redundant leads. Reportedly, the factors influencing the physicians’ decision-making of TLE are the patients’ age, the presence of damaged leads, and lead dwelling time, according to the European EP Wire survey conducted by the European Heart Rhythm Association [2]. The decision-making and procedural outcomes are dependent also on the volume of the extraction referral centers [3]. On the other hand, the situation is different in the case of lead, device, or pocket infection, because such infections may be fatal and it requires intensive antibiotic therapy and total system removal. In this issue of the Journal of Cardiology Cases, Kypta et al. report an interesting case of a 47-year-old female who had undergone tricuspid mechanical valve replacement followed by dual chamber pacemaker implantation due to postoperative complete atrioventricular block. The permanent pacemaker had to be replaced because of battery depletion. She was referred to their institution for TLE because of evident pocket infection [4]. The REPLACE study has demonstrated that cases of device revision or lead addition within a short period of time have high risk of procedure-related infection [5]. These results indicate that careful decision-making and long-term perspective were required in the pacemaker-dependent patients with drug abuse, as in this case when repetitive pacemaker revision and tricuspid valve surgery were performed. The Heart Rhythm Society/European Heart Rhythm Association (EHRA) Guideline recommends complete lead and device removal [6], [7] in the case of pocket infection (Class 1), as in this case evidenced by swab test proven positive for Staphylococcus epidermidis [4]. The guideline includes the principles for infected system removal followed by later contralateral implantation of a new system (Class 1) associated with intensive and appropriate antibiotic therapy. However, simultaneous removal of infected system and implantation of a new system is required occasionally in pacemaker-dependent patients. Amraoui et al. compared the outcomes of delayed transvenous implantation of pacemaker on the opposite site with those of immediate surgical epicardial approach in pacemaker-dependent patients undergoing TLE due to device infection [8]. They concluded that there were equivalent outcomes between the two approaches. However, therapeutic strategy is complicated particularly in the pacemaker-dependent patients undergoing mechanical tricuspid valve replacement. To avoid right ventricular (RV) pacemaker lead trapping, authors postulated three options, i.e. (1) minimally invasive left-sided epicardial leads and device implantation, (2) a coronary sinus (CS) and new right atrial (RA) leads placement associated with a new device on the opposite site, (3) temporary CS pacing followed by a new system implantation at opposite side (two-step approach). Option 1 is a high-risk procedure in this patient undergoing several open-chest surgeries. The same is true in option 3 considering fatal temporary CS lead dislodgement. The remaining option 2 requires the CS lead placement at the same session as infected system removal in this pacemaker-dependent case. A potential proarrhythmic effect has been raised in biventricular pacing using RV and CS leads for heart failure patients [9]. This is partly due to inhomogeneous repolarization caused by focal epicardial activation [10]. Since ventricular transmural excitation propagates from endocardium to epicardium, CS pacing opposes to this physiological activation sequence. Importantly, authors found in this case that QTc interval recorded by single-site pacing at either anterior or posterolateral vein is longer than that recorded by dual-site CS pacing via anterior and lateral veins. Although the reason for this phenomenon is speculative, possible hemodynamic improvement obtained by the dual-site pacing may have abbreviated QRS duration and hence QTc interval. Paced QTc interval is reported to be a better predictor of mortality in pacemaker patients than the intrinsic QTc interval [11]. In this sense, it is appreciated that the authors strived for minimizing the QTc interval by choosing the dual-site CS pacing modality and seeking the optimal target vein. In summary, Kypta et al. present a suggestive and rare case of TLE. As opposed to recommendation of the guideline, they performed a one-step procedure of infected system removal and a contralateral new device implantation using two CS leads due partly to lack of decision-making tools in such a complicated case. Empirical decision-making of TLE in pacemaker-dependent patients with tricuspid mechanical valve may be refined in the near future according to the evolution of sophisticated lead extraction techniques and new pacemaker technology, i.e. TLE using excimer laser sheath is available in Japan since 2009, and permanent leadless pacemakers of Nanostim™ (St. Jude Medical, Sylmar, CA, USA) and Micra™ (Medtronic Inc.) have entered clinical investigation (the LEADLESS trial) and application [12], [13].

Conflicts of interest

None.
  12 in total

1.  Pathways for training and accreditation for transvenous lead extraction: a European Heart Rhythm Association position paper.

Authors:  J C Deharo; M G Bongiorni; A Rozkovec; F Bracke; P Defaye; I Fernandez-Lozano; P G Golzio; B Hansky; C Kennergren; A S Manolis; P Mitkowski; E S Platou
Journal:  Europace       Date:  2012-01       Impact factor: 5.214

2.  Pacing-induced increase in QT dispersion predicts sudden cardiac death following cardiac resynchronization therapy.

Authors:  Shajil Chalil; Zaheer R Yousef; Sarkaw A Muyhaldeen; Russell E A Smith; Paul Jordan; Christopher R Gibbs; Francisco Leyva
Journal:  J Am Coll Cardiol       Date:  2006-06-20       Impact factor: 24.094

3.  Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA).

Authors:  Bruce L Wilkoff; Charles J Love; Charles L Byrd; Maria Grazia Bongiorni; Roger G Carrillo; George H Crossley; Laurence M Epstein; Richard A Friedman; Charles E H Kennergren; Przemyslaw Mitkowski; Raymond H M Schaerf; Oussama M Wazni
Journal:  Heart Rhythm       Date:  2009-05-22       Impact factor: 6.343

4.  Transvenous extraction profile of Riata leads: procedural outcomes and technical complexity of mechanical removal.

Authors:  Maria Grazia Bongiorni; Andrea Di Cori; Luca Segreti; Giulio Zucchelli; Stefano Viani; Luca Paperini; Raffaele De Lucia; Dianora Levorato; Adriano Boem; Ezio Soldati
Journal:  Heart Rhythm       Date:  2014-12-10       Impact factor: 6.343

5.  Management of malfunctioning and recalled pacemaker and defibrillator leads: results of the European Heart Rhythm Association survey.

Authors:  Maria Grazia Bongiorni; Nikolaos Dagres; Heidi Estner; Laurent Pison; Derick Todd; Carina Blomstrom-Lundqvist
Journal:  Europace       Date:  2014-11       Impact factor: 5.214

6.  Paced QT interval is a better predictor of mortality than the intrinsic QT interval: long-term follow-up study.

Authors:  Jung Myung Lee; Ajit H Janardhan; Ki-Woon Kang; Boyoung Joung; Hui-Nam Pak; Srikanth Sundaram; William C Choe; Moon-Hyoung Lee; Hye Jin Hwang
Journal:  Heart Rhythm       Date:  2014-04-12       Impact factor: 6.343

Review 7.  Cardiac resynchronization therapy and its potential proarrhythmic effect.

Authors:  Indranill Basu Ray; Lahn Fendelander; Jagmeet P Singh
Journal:  Clin Cardiol       Date:  2007-10       Impact factor: 2.882

Review 8.  Safety of transvenous lead extraction according to centre volume: a systematic review and meta-analysis.

Authors:  Antonio Di Monaco; Gemma Pelargonio; Maria Lucia Narducci; Lamberto Manzoli; Stefania Boccia; Maria Elena Flacco; Lorenzo Capasso; Lucy Barone; Francesco Perna; Gianluigi Bencardino; Teresa Rio; Milena Leo; Luigi Di Biase; Pasquale Santangeli; Andrea Natale; Antonio Giuseppe Rebuzzi; Filippo Crea
Journal:  Europace       Date:  2014-06-25       Impact factor: 5.214

9.  Permanent leadless cardiac pacing: results of the LEADLESS trial.

Authors:  Vivek Y Reddy; Reinoud E Knops; Johannes Sperzel; Marc A Miller; Jan Petru; Jaroslav Simon; Lucie Sediva; Joris R de Groot; Fleur V Y Tjong; Peter Jacobson; Alan Ostrosff; Srinivas R Dukkipati; Jacob S Koruth; Arthur A M Wilde; Josef Kautzner; Petr Neuzil
Journal:  Circulation       Date:  2014-03-24       Impact factor: 29.690

Review 10.  State of the art of leadless pacing.

Authors:  Johannes Sperzel; Haran Burri; Daniel Gras; Fleur V Y Tjong; Reinoud E Knops; Gerhard Hindricks; Clemens Steinwender; Pascal Defaye
Journal:  Europace       Date:  2015-05-29       Impact factor: 5.214