Literature DB >> 30467907

Effect of margin design on fracture load of zirconia crowns.

Anneli Skjold1, Christian Schriwer1, Marit Øilo1.   

Abstract

Zirconia-based restorations are showing an increase as the clinicians' preferred choice at posterior sites because of the strength and esthetic properties of such restorations. However, all-ceramic restorations fracture at higher rates than do metal-based restorations. Margin design is one of several factors that can affect the fracture strength of all-ceramic restorations. The aim of this study was to assess the effect of preparation and crown margin design on fracture resistance. Four groups of bilayer zirconia crowns (with 10 crowns in each group) were produced by hard- or soft-machining technique, with the following four different margin designs: chamfer preparation (control); slice preparation; slice preparation with an additional cervical collar of 0.7 mm thickness; and reduced occlusal thickness (to 0.4 mm) on slice preparation with an additional cervical collar of 0.7 mm thickness. Additionally, 10 hard-machined crowns with slice preparation were veneered and glazed with feldspathic porcelain. In total, 90 crowns were loaded centrally in the occlusal fossa until fracture. The load at fracture was higher than clinically relevant mastication loads for all preparation and margin designs. The crowns on a chamfer preparation fractured at higher loads compared with crowns on a slice preparation. An additional cervical collar increased load at fracture for hard-machined crowns.
© 2018 The Authors. Eur J Oral Sci published by John Wiley & Sons Ltd.

Entities:  

Keywords:  dental ceramics dental restorations; monolithic; prosthondontics; tooth preparation

Mesh:

Substances:

Year:  2018        PMID: 30467907      PMCID: PMC6587860          DOI: 10.1111/eos.12593

Source DB:  PubMed          Journal:  Eur J Oral Sci        ISSN: 0909-8836            Impact factor:   2.612


All‐ceramic dental restorations are increasingly preferred over metal‐based restorations 1, 2. The early all‐ceramic crowns had lower mechanical strength, which limited their use to the anterior region 1, 2. Polycrystalline ceramics, such as zirconia containing only crystalline particles, allow use of all‐ceramic restorations even at posterior teeth 3, 4. In order to improve the esthetics of zirconia, the crowns can be produced as bilayer crowns with an esthetic veneering layer over the zirconia core. However, the rate of failure of bilayer crowns is still higher than for metal‐based crowns 4, 5, 6, 7, 8, 9. The most frequent clinical failures are chipping and delamination of the veneering layer. Core fractures represent a low percentage of the failures observed in zirconia‐based bilayers in clinical studies 4. The amount of core fractures may, however, be underestimated because of the lack of a sufficient number of clinical studies with an observation period extending beyond 3 yr. Personal communication with dental technicians and practicing dentists indicate that core failure is more common than the scientific evidence indicates. Core fracture can be related to several factors, such as material composition, production method, design, and thickness of the core. In vitro studies have been performed in order to achieve a better insight into the behavior of modern high‐strength zirconia crowns 10, 11. The fracture modes observed with conventional in vitro fracture strength tests often differ from the fracture modes observed with clinically failed zirconia‐based bilayer crowns 11, 12, 13. Differences between clinical observations and in vitro tests are evident in both fracture strength values and crack initiation sites, as well as in crack propagation patterns 14, 15, 16, 17. The fracture pattern of crowns fractured during clinical use demonstrates fracture origins in the cervical margin of the crown 15, 18, 19, 20 or from the intaglio surface of the crown 21, 22, 23 (Fig. 1). Margin failures often occur at the proximal area of the crown, where the finish line curves toward the occlusal surface over the gingival papilla 24.
Figure 1

Three different fracture modes have been observed with zirconia‐based crowns fractured in clinical use (ongoing retrieval study). (A) Total fracture in two to three pieces, usually originating in the proximal margin area. (B) Total fracture in three pieces or more, with the fracture originating in the intaglio occlusal wall in a thin region of the crown. (C) Margin chip, usually observed on buccal or lingual flange. Open arrows indicate fracture origin. Black arrows indicate direction of crack propagation.

Three different fracture modes have been observed with zirconia‐based crowns fractured in clinical use (ongoing retrieval study). (A) Total fracture in two to three pieces, usually originating in the proximal margin area. (B) Total fracture in three pieces or more, with the fracture originating in the intaglio occlusal wall in a thin region of the crown. (C) Margin chip, usually observed on buccal or lingual flange. Open arrows indicate fracture origin. Black arrows indicate direction of crack propagation. Margin failures may be related to the design and thickness of the crown margins. Multiple studies have been performed in order to evaluate the effect of margin design on load at fracture, but the results are inconclusive. Several studies find that the margin design has an effect on the fracture resistance 24, 25, 26, 27, 28, 29, while others see no such effect 30, 31. The large differences in study design among these trials complicate comparison and conclusions on this issue. Clinical recommendations for margin design are based on previous experiences with all‐ceramic crowns and also on the design of metal‐based crowns. It is not evident whether these recommendations are optimal for the modern high‐strength zirconia restorations. Most manufacturers of dental ceramics advise dentists to remove up to 0.5–1.5 mm of tooth substance to make room for a bilayer ceramic crown. A preparation depth of 1.5 mm increases the risk of negative effects on tooth vitality 32, 33. Based on mechanical properties, zirconia crowns can probably be made using a minimal invasive slice preparation technique, as suggested by some manufacturers and in scientific papers 34, 35. However, it is still uncertain which design provides optimal balance between crown strength and tooth vitality. The aim of this study was to analyze the effect of different preparation and crown margin designs on load at fracture for bilayer zirconia crowns.

Material and methods

Crown preparation and margin designs

Two artificial models of premolar teeth were prepared for all‐ceramic crowns with an axial wall taper of 10 degrees and rounded edges. Two different finish line designs were prepared. One model had a circumferential chamfer preparation of 0.5 mm depth; the other had a circumferential slice preparation (Fig. 2).
Figure 2

Two different types of preparations used in the test (lateral view).

Two different types of preparations used in the test (lateral view). Impressions of each preparation were taken using an A‐silicone impression material (Affinis; Coltene, Altsätten, Switzerland), and stone models of the preparation were scanned. The three‐dimensional (3D) digital files were used for designing the cores (Fig. 3A–C). The cores were designed and produced by a dental technician according to the protocol. Four different designs were made: uniform‐thickness (0.5 mm) crowns on the chamfer preparation [control (C)]; uniform‐thickness (0.5 mm) crowns on the slice preparation (S); uniform‐thickness (0.5 mm) crowns on the slice preparation with an additional 0.8 mm high cervical collar in the mesiolingual‐distal region (S + Col); and finally, reduced occlusal thickness (to 0.4 mm) crowns on the slice preparation with a 0.8 mm high cervical collar (S + Colr) (Fig. 3D).
Figure 3

Three different margin designs (lateral view): chamfer preparation with uniform thickness (control) (A); slice preparation with a partial cervical collar (B); and slice preparation with a uniform thickness (0.5 mm) (C). In addition, one set of 10 crowns identical to those in panel B were made with reduced occlusal thickness (0.4 mm). (D) Measurements of the wall thickness of the four margin designs are shown (in cross section). The thickness is measured at the same height as the upper limit of the cervical collar. The different designs are chamfer (C), slice (S), slice with veneering layer (S + V), and slice with cervical collar (S + Col).

Three different margin designs (lateral view): chamfer preparation with uniform thickness (control) (A); slice preparation with a partial cervical collar (B); and slice preparation with a uniform thickness (0.5 mm) (C). In addition, one set of 10 crowns identical to those in panel B were made with reduced occlusal thickness (0.4 mm). (D) Measurements of the wall thickness of the four margin designs are shown (in cross section). The thickness is measured at the same height as the upper limit of the cervical collar. The different designs are chamfer (C), slice (S), slice with veneering layer (S + V), and slice with cervical collar (S + Col). Ten crowns of each material were manufactured for each of the four designs according to instructions from the manufacturers. One set of 40 crowns was produced using a soft‐machining technique (SM) (Zerion HSC zirconium oxide ceramic single unit; Institut Straumann, Basel, Switzerland) and another set of 40 crowns was produced, with the same specifications, using a hard‐machining technique (HM) (Denzir Y‐TZP; Denzir Cad.esthetics, Skellefteå, Sweden). In addition, 10 HM crowns made for the slice preparation were veneered and glazed with feldspathic porcelain (S + V) (Fig. 4).
Figure 4

Flow chart of the crown production. The veneered crowns are indicated with darker shadow.

Flow chart of the crown production. The veneered crowns are indicated with darker shadow. The cusps were designed with equal heights and aligned to prevent the crowns from tilting backwards during loading. The central fossa was designed to be rounded and shallow on the occlusal surface to increase the contact area between the crown and the indenter in order to disperse the load evenly and avoid localized contact damage.

Precementation examinations of margin defects

The crowns were examined at 10× magnification in an optical stereomicroscope (Leica M205 C; Leica Microsystems, Wetzlar, Germany) for signs of marginal defects. All defects or irregularities were registered and graded on a scale of 1–5, according to severity, on a Likert scale, as follows: 1, optimal margins without flaws; 2, minor chips and flaws; 3, multiple chips and flaws; 4, continuous flaws or uneven margins; and 5, large defects visible without a microscope 36. The SM crowns were manually adjusted externally at the margin after delivery from the technician to achieve an acceptable marginal thickness edge equivalent with the margins of the HM crowns. The margin adjustment was performed using a dental handpiece (KaVo K‐Control; Kavo, Biberach an den Riss, Germany) according to the manufacturer's recommendations. The crowns were re‐examined to ensure that no defects had occurred during the adjustments.

Load testing

The crowns were cemented to epoxy models (EpoFix; Struers, Ballerup, Denmark) of the preparations with zinc phosphate oxide cement (De Trey Zink; Dentsply DeTrey, Konstanz, Germany). The cement was chosen to minimize the bonding effect of the cement. Excess cement was removed, and after a 5‐min setting time the crowns were placed in distilled water at 37°C for 24 (range ± 2) h. The crowns were subsequently loaded centrally at the occlusal fossa with a horizontal cylindrical steel indenter of 13 mm in diameter, cushioned with a 2‐mm‐thick ethylene propylene diene rubber disc of hardness 90 Shore A (EPDM 90) to avoid contact damage. The cylinder was placed centrally to ensure even distribution of load between the cusps. The load was applied in a servo hydraulic testing system at 0.5 mm min−1 until fracture occurred (MTS 852 MiniBionix II; MTS Systems, Eden Prairie, MN, USA). The procedures were performed while the crowns were immersed in water at room temperature. Load at fracture was recorded. At 3,300 N, the procedure was halted because of equipment limitation. The fractured crowns were analyzed, using fractographic methods, to identify the fracture origin and direction of crack propagation 16, 37. The fracture initiation area was compared with the crown margins before fracture, to assess whether pre‐existing defects were the fracture initiators or not.

Statistical analysis

As a result of the limited number of specimens in each group and a tendency for skewed data, non‐parametric methods were used to analyze the results. The Kruskal–Wallis test was used for overall comparison and the Mann–Whitney U‐test was used for between‐group testing, with correction for multiple groups. Assessment of correlations was performed using Spearman's rank test. Significance was set to α = 0.05.

Results

After the loading test, 11 of 90 crowns did not fracture, mainly in the control groups with a chamfer preparation design (Figs 5 and 6, Table 1). Their load value was set to 3,300 N. Overall comparison of all data shows significant differences among the nine test groups (P = 0.0001).
Figure 5

Box plot of the five hard‐machined groups with different margin designs. Further load was stopped at 3,300 N (horizontal reference line at y‐axis) as a result of equipment limitation. The line within boxes represents the median, and the bottom and top of boxes represent the first and third quartiles, respectively. The maximum and minimum whiskers represent 1.5 interquartile ranges. There were statistically significant differences among all the groups, except for comparison between the chamfer (C) group and the slice with cervical collar (S + Col) group (shown with triangles). S, slice; S + Colr, slice with collar and reduced occlusal thickness.

Figure 6

Box plot of the four soft‐machined groups with different margin designs. Further load was stopped at 3,300 N (horizontal reference line at y‐axis) as a result of equipment limitation. The line within boxes represents the median, and the bottom and top of boxes represent the first and third quartiles, respectively. The maximum and minimum whiskers represent 1.5 interquartile ranges. Statistically significant differences between groups are marked with corresponding squares or diamonds. C, chamfer; S, slice; S + Colr, slice with cervical collar and reduced occlusal thickness; S + Col, slice with cervical collar.

Table 1

Overview of the fracture origin and margin quality evaluation

Production methodMargin designsFracture originMargin defect mean value
CervicalIntaglio occlusal surfaceNon‐fractured crowns
Hard‐machinedChamfer (control)551.6
Slice with cervical collar6312.8
Slice with cervical collar and reduced occlusal thickness103.2
Slice no collar1811.5
Slice with collar and veneering7212
Soft‐machinedChamfer (control)732.5
Slice with cervical collar102.6
Slice with cervical collar and reduced occlusal thickness19 2.9
Slice no collar283
Total225711
Box plot of the five hard‐machined groups with different margin designs. Further load was stopped at 3,300 N (horizontal reference line at y‐axis) as a result of equipment limitation. The line within boxes represents the median, and the bottom and top of boxes represent the first and third quartiles, respectively. The maximum and minimum whiskers represent 1.5 interquartile ranges. There were statistically significant differences among all the groups, except for comparison between the chamfer (C) group and the slice with cervical collar (S + Col) group (shown with triangles). S, slice; S + Colr, slice with collar and reduced occlusal thickness. Box plot of the four soft‐machined groups with different margin designs. Further load was stopped at 3,300 N (horizontal reference line at y‐axis) as a result of equipment limitation. The line within boxes represents the median, and the bottom and top of boxes represent the first and third quartiles, respectively. The maximum and minimum whiskers represent 1.5 interquartile ranges. Statistically significant differences between groups are marked with corresponding squares or diamonds. C, chamfer; S, slice; S + Colr, slice with cervical collar and reduced occlusal thickness; S + Col, slice with cervical collar. Overview of the fracture origin and margin quality evaluation In the HM groups, there were significant differences between all groups except between the control group (chamfer) and the group with a cervical collar of standard occlusal thickness. By contrast, in the SM groups, there were no significant differences except between the control group (chamfer) and the two groups with a cervical collar for both types of occlusal thicknesses. Fractographic analysis revealed that no crowns fractured because of contact damage between the indenter and the crowns, as detected by light microscopy. Crowns fractured either from the crown margin (n = 22, Figs 7 and 8) or from the intaglio surface of the crown (n = 57, Fig. 9). Most crowns fractured into two or three pieces. Twenty‐four of 90 crowns fractured into four or five pieces.
Figure 7

Fractographic map of a non‐veneered soft‐machined crown with slice preparation without a cervical collar. Black arrows show direction of crack propagation originating at the cervical edge of the crown.

Figure 8

Fractographic map of a veneered hard‐machined crown with slice preparation without a cervical collar. Black arrows show direction of crack propagation originating at the cervical edge of the crown.

Figure 9

Fractographic map of a non‐veneered hard‐machined crown with slice preparation without a cervical collar. Blue arrows show direction of crack propagation originating at the intaglio occlusal surface of the crown.

Fractographic map of a non‐veneered soft‐machined crown with slice preparation without a cervical collar. Black arrows show direction of crack propagation originating at the cervical edge of the crown. Fractographic map of a veneered hard‐machined crown with slice preparation without a cervical collar. Black arrows show direction of crack propagation originating at the cervical edge of the crown. Fractographic map of a non‐veneered hard‐machined crown with slice preparation without a cervical collar. Blue arrows show direction of crack propagation originating at the intaglio occlusal surface of the crown. There was no statistically significant correlation between fracture mode and load at fracture overall (r = 0.26) or within groups (r = 0.39 for HM groups and r = 0.04 for SM groups). There was no statistically significant correlation between margin defects and load at fracture (r = 0.25).

Discussion

The overall results indicate that preparation design, crown design, and manufacturing method affect load at fracture. The different design variables assessed in this study are not independent. An alteration in one of the design variables also causes change in other variables. Furthermore, the effect of each variable differed between the two materials tested. Nonetheless, some effects of the different variables can be isolated. The finding that the chamfer design crowns fractured at a higher load than did the slice design crowns in both production‐method groups indicates that the commonly recommended chamfer margin design gives the strongest crowns. This is in accordance with previous studies 12, 27, 38, 39, 40, 41, 42, 43, 44. The increased thickness in the crown margin probably explains this result. Thick crown walls can, however, compromise tooth vitality by requiring increased drilling depth 33, 45, 46. The finding that all crowns fractured at a higher level than maximal mastication forces indicates that slice preparation design might result in sufficiently strong crowns 47. Further studies must be performed to evaluate this in a clinical setting. The increased margin thickness in the collar resulted in an increase of almost 20% in load at fracture compared with uniform thickness slice preparation for the HM group. This is in accordance with previous findings 48, 49, 50. The additional collar results in fracture loads equal to the crowns made for the chamfer design. However, another study did not find a strengthening effect of a cervical collar similar to the results for the SM group in the present study 51. Slice preparation may be associated with biological benefits as it requires less removal of sound tooth substance. On the other hand, an over‐contoured crown margin may compromise gingival and periodontal health 52. Thus, a highly polished zirconia margin with no veneer may be less plaque retentive than a zirconia core veneered down to the crown margins because the latter will be bulkier. These findings indicate that a slice preparation with a modified crown design may increase both technical and biological success. Reducing the occlusal thickness resulted in weaker crowns as expected based on previous studies (27, 40, 41, 42, 43, 47). This was, however, only statistically significant for the HM group. The results indicate that a change in occlusal thickness may have a greater effect on the load at fracture values than cervical thickness. The veneered crowns fractured at statistically significantly lower loads than the identical non‐veneered crowns. This indicates that post‐treatment of zirconia cores adversely affects fracture strength 53, 54. Only one HM group was veneered in this study; further studies are needed to assess the effect also on other zirconia cores. Based on previous studies, a larger difference in load at fracture between HM and SM crowns had been expected 36. Our findings cannot fully explain why this is not the case in the present study. The results indicate that different margin designs have a more pronounced effect on the fracture resistance in HM zirconia cores for bilayer all‐ceramic crowns than in SM zirconia cores. This difference may be a result of microscopic‐level changes in the zirconia material occurring during the production by the two different methods. A final sintering of the SM zirconia may have a reducing effect on the microscopic defects that may have occurred during milling. Furthermore, the post‐sintering adjustment necessary on the margins of the SM crowns to achieve optimal fit and crown emergence profile can affect fracture resistance. The SM restorations are milled with slightly over‐contoured margins in the computer‐aided design/computer‐aided manufacturing (CAD/CAM) unit in order to reduce the risk of margin chips. Manual adjustment of the margins could theoretically have had a reinforcing effect on the core by introducing a t‐m phase transformation toughening effect at the molecular level. On the other hand, post sintering margin adjustment of the SM crowns can also introduce new defects, although none was observed in this study. The finding that only three crowns had fracture origins in pre‐existing defects indicates that margin flaws are not very detrimental to crown strength. It can, however, not be excluded that pre‐existing defects not detectable by light microscopy may contribute to crack initiation 18. Further studies of the effect of margin quality are needed to assess this. The difference in fracture modes among the test groups indicates that both different production methods and designs affect fracture initiation and crack propagation. All fractured crowns in the present study fractured either from the margin or at the intaglio surface, as have been previously reported to be clinically relevant fracture patterns. The rubber disc placed between the indenter and the zirconia cores during loading prevented visible contact damage. It is reasonable to expect, however, that some contact damage has occurred at a microscopic level, although the effect of this is not obvious in the present study. The finding that more than two‐thirds of the crowns fractured from the intaglio occlusal surface indicates that occlusal thickness is also important for crown survival. This is in accordance with previous studies in which thinner walls resulted in weaker crowns 41, 44, 55. The finding that the crowns with reduced occlusal thickness had lower fracture loads further supports this point. The loading test configuration may explain the large proportion of fractures originating in the occlusal intaglio surface. The cylindrical indenter used to load the bicuspid zirconia cores may have created a wedging effect in addition to the axial load. Furthermore, the cement layer immediately beneath the loading area may have been crushed during loading, resulting in a local failure of the support of the zirconia core and leading to tensile stress and subsequent cracks at the intaglio surface. The cement used in this study was chosen in order to study zirconia cores without adhesive effects from the cement. This could produce somewhat different results from clinical situations and with other cements. The failure mode is, however, similar to clinical failures observed in an ongoing retrieval study, as seen in Fig. 1. Previous studies reveal that alterations in margins design affect the cervical stress distribution 38, 49. The lowest load at fracture was 1,202 N, which is higher than the maximally measured biting force of 800–1,000 N 56. Considering the fact that the crowns in this study were not subjected to aging prior to testing and that they were produced and cemented under optimal conditions, the results can, nevertheless, be considered clinically relevant and indicate that zirconia‐based crowns can fracture during normal mastication forces if the design is poor or if there is a defect in a tensile stress location. Within the limitations of this study, it can be concluded that zirconia crowns made for a chamfer preparation fracture at significantly higher loads than similar crowns made for a slice preparation design. Both preparation designs resulted in crowns that fractured at loads above normal mastication forces. A slice preparation with a modified cervical collar crown design may increase both technical and biological success. The veneering process decreases the fracture resistance significantly, just as reduced wall thickness reduces load at fracture.

Conflict of interests

The authors declare no conflict of interests..
  54 in total

Review 1.  Survival and complications of zirconia-based fixed dental prostheses: a systematic review.

Authors:  Ariel J Raigrodski; Matthew B Hillstead; Graham K Meng; Kwok-Hung Chung
Journal:  J Prosthet Dent       Date:  2012-03       Impact factor: 3.426

2.  The effect of finish line preparation and layer thickness on the failure load and fractography of ZrO2 copings.

Authors:  Sven Reich; Anselm Petschelt; Ulrich Lohbauer
Journal:  J Prosthet Dent       Date:  2008-05       Impact factor: 3.426

3.  Durability and Weibull Characteristics of Lithium Disilicate Crowns Bonded on Abutments with Knife-Edge and Large Chamfer Finish Lines after Cyclic Loading.

Authors:  Davide Cortellini; Angelo Canale; Rodrigo O A Souza; Fernanda Campos; Julia C Lima; Mutlu Özcan
Journal:  J Prosthodont       Date:  2014-10-15       Impact factor: 2.752

Review 4.  A systematic review of all-ceramic crowns: clinical fracture rates in relation to restored tooth type.

Authors:  Xiaodong Wang; Danni Fan; Michael Vincent Swain; Ke Zhao
Journal:  Int J Prosthodont       Date:  2012 Sep-Oct       Impact factor: 1.681

5.  Fracture surface analysis of dental ceramics: clinically failed restorations.

Authors:  J R Kelly; R Giordano; R Pober; M J Cima
Journal:  Int J Prosthodont       Date:  1990 Sep-Oct       Impact factor: 1.681

6.  Load at fracture of monolithic and bilayered zirconia crowns with and without a cervical zirconia collar.

Authors:  Marit Øilo; Ketil Kvam; Nils Roar Gjerdet
Journal:  J Prosthet Dent       Date:  2016-01-13       Impact factor: 3.426

7.  Fracture surface characterization of clinically failed all-ceramic crowns.

Authors:  J Y Thompson; K J Anusavice; A Naman; H F Morris
Journal:  J Dent Res       Date:  1994-12       Impact factor: 6.116

8.  Clinical performance and failures of zirconia-based fixed partial dentures: a review literature.

Authors:  Premwara Triwatana; Noppavan Nagaviroj; Chantana Tulapornchai
Journal:  J Adv Prosthodont       Date:  2012-05-30       Impact factor: 1.904

9.  Influence of Different Framework Designs on the Fracture Properties of Ceria-Stabilized Tetragonal Zirconia/Alumina-Based All-Ceramic Crowns.

Authors:  Tomofumi Sawada; Sebastian Spintzyk; Christine Schille; Ernst Schweizer; Lutz Scheideler; Jürgen Geis-Gerstorfer
Journal:  Materials (Basel)       Date:  2016-05-05       Impact factor: 3.623

10.  Effect of margin design on fracture load of zirconia crowns.

Authors:  Anneli Skjold; Christian Schriwer; Marit Øilo
Journal:  Eur J Oral Sci       Date:  2018-11-22       Impact factor: 2.612

View more
  6 in total

1.  Effect of Marginal Designs on Fracture Strength of High Translucency Monolithic Zirconia Crowns.

Authors:  Niwut Juntavee; Sasiprapa Kornrum
Journal:  Int J Dent       Date:  2020-08-03

2.  Effect of margin design on fracture load of zirconia crowns.

Authors:  Anneli Skjold; Christian Schriwer; Marit Øilo
Journal:  Eur J Oral Sci       Date:  2018-11-22       Impact factor: 2.612

3.  Fracture Strength of Monolithic Zirconia Crowns with Modified Vertical Preparation: A Comparative In Vitro Study.

Authors:  Marwah Ismael Abdulazeez; Manhal A Majeed
Journal:  Eur J Dent       Date:  2021-11-30

4.  Biaxial Flexural Strength of High-Translucence Monolithic Ceramics upon Various Thicknesses.

Authors:  Niwut Juntavee; Apa Juntavee; Sirintana Phetpanompond
Journal:  ScientificWorldJournal       Date:  2021-10-06

5.  Fracture Resistance of Sintered Monolithic Zirconia Dioxide in Different Thermal Units.

Authors:  Andrea Ordoñez Balladares; Cristian Abad-Coronel; Joao Carlos Ramos; Benjamín José Martín Biedma
Journal:  Materials (Basel)       Date:  2022-03-27       Impact factor: 3.623

6.  Influence of preparation design on fracture resistance of different monolithic zirconia crowns: A comparative study.

Authors:  Meelad Basil Findakly; Haider Hasan Jasim
Journal:  J Adv Prosthodont       Date:  2019-12-18       Impact factor: 1.904

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.