The effect of finish line preparation and layer thickness on the failure load and fractography of ZrO2 copings.

Sven Reich1, Anselm Petschelt, Ulrich Lohbauer.   

Abstract

STATEMENT OF PROBLEM: To prevent tooth weakening or pulp irritation, there is a need for a minimally invasive method of preparing single anterior crowns. Restoration dimensions for reduced coping thicknesses or less invasive finish line preparations are required.
PURPOSE: The purposed of this in vitro was to study investigate the fracture performance of high-strength zirconia copings, compare knife-edge margins with chamfer finish lines, and examine the effect of reducing the layer thickness from 0.5 mm to 0.3 mm.
MATERIAL AND METHODS: Y-TZP zirconia copings were manufactured on brass dies of a maxillary central incisor. Forty copings, with 2 layer thicknesses (0.5 and 0.3 mm), and 2 finish line preparations (knife edge and chamfer; n=10) were cemented using a conventional glass ionomer cement and stored in distilled water at 37 degrees C for 24 hours. The copings were vertically loaded until fracture using a universal testing machine. Data were analyzed by 2-way ANOVA (alpha=.05). Fractographic examination was performed using scanning electron microscopy and confocal laser scanning microscopy.
RESULTS: A significantly higher mean failure load was measured for knife-edge (0.5 mm, 1110 +/-175 N; 0.3 mm, 730 +/-160 N) versus chamfer (0.5 mm, 697 +/-126 N; 0.3 mm, 455 +/-79 N) preparations (P<.001), and for 0.5-mm versus 0.3-mm thickness layers (P<.001).
CONCLUSIONS: Knife-edge preparations present a promising alternative to chamfer finish lines; the fracture load required for knife-edge preparations was 38% greater than that required for chamfer preparations, regardless of coping thickness. Reducing the thickness of a single crown coping from 0.5 to 0.3 mm resulted in a 35% reduction in fracture load required for either preparation type.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18456048     DOI: 10.1016/S0022-3913(08)60085-2

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  12 in total

1.  Influence of the fabrication process on the in vitro performance of fixed dental prostheses with zirconia substructures.

Authors:  Martin Rosentritt; Carola Kolbeck; Gerhard Handel; Sibylle Schneider-Feyrer; Michael Behr
Journal:  Clin Oral Investig       Date:  2010-10-05       Impact factor: 3.573

Review 2.  Performance of dental ceramics: challenges for improvements.

Authors:  E D Rekow; N R F A Silva; P G Coelho; Y Zhang; P Guess; V P Thompson
Journal:  J Dent Res       Date:  2011-01-11       Impact factor: 6.116

Review 3.  Tooth preparation for full-coverage restorations-a literature review.

Authors:  Anke Podhorsky; Peter Rehmann; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2015-03-07       Impact factor: 3.573

4.  Comparison of Marginal Fit and Fracture Strength of a CAD/CAM Zirconia Crown with Two Preparation Designs.

Authors:  Hamid Jalali; Leyla Sadighpour; Ali Miri; Ahmad Reza Shamshiri
Journal:  J Dent (Tehran)       Date:  2015-12

5.  Fracture Resistance of Zirconia Restorations with a Modified Framework Design.

Authors:  Sakineh Nikzadjamnani; Abbas Azari; Somayeh Niakan; Seyedeh Fatemeh Namdar
Journal:  J Dent (Tehran)       Date:  2017-11

6.  Effect of margin design on fracture load of zirconia crowns.

Authors:  Anneli Skjold; Christian Schriwer; Marit Øilo
Journal:  Eur J Oral Sci       Date:  2018-11-22       Impact factor: 2.612

7.  The Effect of Finish Line Design on the Fracture Strength of Zirconia Copings.

Authors:  Zahra Hashemi Ardakani; Sahar Khorsandipour; Mina Mohaghegh; Seyed Ahmad Ghoreishian; Amir Ali Reza Khaledi
Journal:  J Dent (Shiraz)       Date:  2019-12

8.  Marginal Fit of Full Contour Monolithic Zirconia in Different Thicknesses and Layered Zirconia Crowns.

Authors:  Mina Mohaghegh; Maryam Firouzmandi; Elham Ansarifard; Laleh Ramazani
Journal:  J Int Soc Prev Community Dent       Date:  2020-09-28

9.  Simulation of clinical fractures for three different all-ceramic crowns.

Authors:  Marit Oilo; Ketil Kvam; Nils R Gjerdet
Journal:  Eur J Oral Sci       Date:  2014-04-04       Impact factor: 2.612

10.  Influence of preparation design on fracture resistance of different monolithic zirconia crowns: A comparative study.

Authors:  Meelad Basil Findakly; Haider Hasan Jasim
Journal:  J Adv Prosthodont       Date:  2019-12-18       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.