Literature DB >> 30382178

Accuracy of blood pressure monitoring devices: a critical need for improvement that could resolve discrepancy in hypertension guidelines.

James E Sharman1, Thomas H Marwick2.   

Abstract

Hypertension is the most significant modifiable risk factor for cardiovascular disease and contributes to the highest global burden of disease. Blood pressure (BP) measurement is among the most important of all medical tests, and it is critical for BP monitoring devices to be accurate. Comprehensive new evidence from meta-analyses clearly shows that many BP monitoring devices (including oscillometric machines and "gold standard" mercury auscultation) do not accurately represent the BP within the arteries at the upper arm (brachial) or central aorta. Particular variability in the accuracy of BP devices compared with intra-arterial BP has been demonstrated in the cuff BP range from prehypertension to grade I hypertension (systolic BP 120-159 to diastolic BP 80-99 mmHg). This is within the BP range that is most common among people worldwide and, thus almost certainly, feeding confusion around optimal hypertension guideline thresholds. At the individual level, inaccurate BP devices have major potential consequences for best practice patient management, where underestimation of true BP is a missed opportunity to lower cardiovascular risk (with therapeutics or lifestyle) and overestimation of true BP could lead to overmedication. Each problem leads to increased cost from preventable cardiovascular events and unnecessary medications. Altogether, there is a critical need to improve the accuracy standards of BP monitoring devices. In the meantime, out-of-office BP (24 h of ambulatory BP and/or home BP monitoring) or automated, unobserved in-office BP monitoring that takes the average of multiple readings using validated devices are the best available options to determine BP control.

Entities:  

Mesh:

Year:  2018        PMID: 30382178     DOI: 10.1038/s41371-018-0122-6

Source DB:  PubMed          Journal:  J Hum Hypertens        ISSN: 0950-9240            Impact factor:   3.012


  35 in total

1.  Primary prevention of hypertension: clinical and public health advisory from The National High Blood Pressure Education Program.

Authors:  Paul K Whelton; Jiang He; Lawrence J Appel; Jeffrey A Cutler; Stephen Havas; Theodore A Kotchen; Edward J Roccella; Ron Stout; Carlos Vallbona; Mary C Winston; Joanne Karimbakas
Journal:  JAMA       Date:  2002-10-16       Impact factor: 56.272

2.  Performance of the AM-5600 blood pressure monitor: comparison with ambulatory intra-arterial pressure.

Authors:  S Omboni; G Parati; A Groppelli; L Ulian; G Mancia
Journal:  J Appl Physiol (1985)       Date:  1997-02

Review 3.  Are the American Heart Association/American College of Cardiology High Blood Pressure Guidelines Fit for Global Purpose?: Thoughts From the International Society of Hypertension.

Authors:  Neil R Poulter; Rafael Castillo; Fadi J Charchar; Markus P Schlaich; Aletta E Schutte; Maciej Tomaszewski; Rhian M Touyz; Ji-Guang Wang
Journal:  Hypertension       Date:  2018-07-02       Impact factor: 10.190

4.  Disparities between aortic and peripheral pulse pressures induced by upright exercise and vasomotor changes in man.

Authors:  L B Rowell; G L Brengelmann; J R Blackmon; R A Bruce; J A Murray
Journal:  Circulation       Date:  1968-06       Impact factor: 29.690

5.  Comparison of noninvasive oscillometric and intra-arterial blood pressure measurements in hyperacute stroke.

Authors:  Efstathios Manios; Konstantinos Vemmos; Georgios Tsivgoulis; Gerasimos Barlas; Eleni Koroboki; Koroboki Eleni; Konstantinos Spengos; Nikolaos Zakopoulos
Journal:  Blood Press Monit       Date:  2007-06       Impact factor: 1.444

Review 6.  An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man.

Authors:  M Karamanoglu; M F O'Rourke; A P Avolio; R P Kelly
Journal:  Eur Heart J       Date:  1993-02       Impact factor: 29.983

Review 7.  Central blood pressure: current evidence and clinical importance.

Authors:  Carmel M McEniery; John R Cockcroft; Mary J Roman; Stanley S Franklin; Ian B Wilkinson
Journal:  Eur Heart J       Date:  2014-01-23       Impact factor: 29.983

Review 8.  2017 ACC/AHA/AAPA/ABC/ACPM/AGS/APhA/ASH/ASPC/NMA/PCNA Guideline for the Prevention, Detection, Evaluation, and Management of High Blood Pressure in Adults: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines.

Authors:  Paul K Whelton; Robert M Carey; Wilbert S Aronow; Donald E Casey; Karen J Collins; Cheryl Dennison Himmelfarb; Sondra M DePalma; Samuel Gidding; Kenneth A Jamerson; Daniel W Jones; Eric J MacLaughlin; Paul Muntner; Bruce Ovbiagele; Sidney C Smith; Crystal C Spencer; Randall S Stafford; Sandra J Taler; Randal J Thomas; Kim A Williams; Jeff D Williamson; Jackson T Wright
Journal:  Hypertension       Date:  2017-11-13       Impact factor: 9.897

9.  A randomized pilot study of aortic waveform guided therapy in chronic heart failure.

Authors:  Barry A Borlaug; Thomas P Olson; Sahar S Abdelmoneim; Sahar Abdelmoneim Mohamed; Vojtech Melenovsky; Vincent L Sorrell; Kelly Noonan; Grace Lin; Margaret M Redfield
Journal:  J Am Heart Assoc       Date:  2014-03-20       Impact factor: 5.501

10.  Home blood pressure monitoring: Australian Expert Consensus Statement.

Authors:  James E Sharman; Faline S Howes; Geoffrey A Head; Barry P McGrath; Michael Stowasser; Markus Schlaich; Paul Glasziou; Mark R Nelson
Journal:  J Hypertens       Date:  2015-09       Impact factor: 4.844

View more
  6 in total

1.  Influence of Age on Upper Arm Cuff Blood Pressure Measurement.

Authors:  Dean S Picone; Martin G Schultz; Petr Otahal; J Andrew Black; Willem J Bos; Chen-Huan Chen; Hao-Min Cheng; Antoine Cremer; Nathan Dwyer; Ricardo Fonseca; Alun D Hughes; Hack-Lyoung Kim; Peter S Lacy; Esben Laugesen; Nobuyuki Ohte; Stefano Omboni; Christian Ott; Telmo Pereira; Giacomo Pucci; Philip Roberts-Thomson; Niklas B Rossen; Roland E Schmieder; Daisuke Sueta; Kenji Takazawa; Jiguang Wang; Thomas Weber; Berend E Westerhof; Bryan Williams; Hirotsugu Yamada; Eiichiro Yamamoto; James E Sharman
Journal:  Hypertension       Date:  2020-01-27       Impact factor: 10.190

2.  Real-time estimation of mean arterial blood pressure based on photoplethysmography dicrotic notch and perfusion index. A pilot study.

Authors:  Jona Joachim; Maxime Coutrot; Sandrine Millasseau; Joaquim Matéo; Alexandre Mebazaa; Etienne Gayat; Fabrice Vallée
Journal:  J Clin Monit Comput       Date:  2020-02-20       Impact factor: 2.502

Review 3.  Blood pressure measurement using only a smartphone.

Authors:  Lorenz Frey; Carlo Menon; Mohamed Elgendi
Journal:  NPJ Digit Med       Date:  2022-07-06

4.  Agreement and Reliability of Clinician-in-Clinic Versus Patient-at-Home Clinical and Functional Assessments: Implications for Telehealth Services.

Authors:  Shelley E Keating; Amandine Barnett; Ilaria Croci; Amy Hannigan; Louise Elvin-Walsh; Jeff S Coombes; Katrina L Campbell; Graeme A Macdonald; Ingrid J Hickman
Journal:  Arch Rehabil Res Clin Transl       Date:  2020-06-07

5.  Lancet Commission on Hypertension group position statement on the global improvement of accuracy standards for devices that measure blood pressure.

Authors:  James E Sharman; Eoin O'Brien; Bruce Alpert; Aletta E Schutte; Christian Delles; Michael Hecht Olsen; Roland Asmar; Neil Atkins; Eduardo Barbosa; David Calhoun; Norm R C Campbell; John Chalmers; Ivor Benjamin; Garry Jennings; Stéphane Laurent; Pierre Boutouyrie; Patricio Lopez-Jaramillo; Richard J McManus; Anastasia S Mihailidou; Pedro Ordunez; Raj Padwal; Paolo Palatini; Gianfranco Parati; Neil Poulter; Michael K Rakotz; Clive Rosendorff; Francesca Saladini; Angelo Scuteri; Weimar Sebba Barroso; Myeong-Chan Cho; Ki-Chul Sung; Raymond R Townsend; Ji-Guang Wang; Tine Willum Hansen; Gregory Wozniak; George Stergiou
Journal:  J Hypertens       Date:  2020-01       Impact factor: 4.776

6.  [Lancet Commission on Hypertension Group position statement on the global improvement of accuracy standards for devices that measure blood pressurePosicionamento do Grupo da Lancet Commission on Hypertension sobre a melhoria global dos padrões de acurácia para aparelhos que medem a pressão arterial].

Authors:  James E Sharman; Eoin O'Brien; Bruce Alpert; Aletta E Schutte; Christian Delles; Michael Hecht Olsen; Roland Asmar; Neil Atkins; Eduardo Barbosa; David Calhoun; Norm R C Campbell; John Chalmers; Ivor Benjamin; Garry Jennings; Stéphane Laurent; Pierre Boutouyrie; Patricio Lopez-Jaramillo; Richard J McManus; Anastasia S Mihailidou; Pedro Ordunez; Raj Padwal; Paolo Palatini; Gianfranco Parati; Neil Poulter; Michael K Rakotz; Clive Rosendorff; Francesca Saladini; Angelo Scuteri; Weimar Sebba Barroso; Myeong-Chan Cho; Ki-Chul Sung; Raymond R Townsend; Ji-Guang Wang; Tine Willum Hansen; Gregory Wozniak; George Stergiou
Journal:  Rev Panam Salud Publica       Date:  2020-03-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.