Najlaa M Alamoudi1, Alaa M Baik2, Azza A El-Housseiny3,4, Tariq S Abu Haimed5, Ahmed S Bakry6,7.
Abstract
BACKGROUND: Previous studies had reported that bond strength deteriorate over time following the dentin surface pretreatment with chlorhexidine. Therefore, further investigations are needed to evaluate the effect of other materials such as povidone iodine. The purpose of this study was to investigate the effects of 10% povidone-iodine pretreatment on the resin-dentin micro-tensile bond strength of a single bond adhesive system in permanent teeth over time, and compare it with 2% chlorhexidine.Entities:
Keywords: Chlorhexidine; Matrix metalloproteinase; Micro-tensile bond strength; Povidone-iodine
Mesh:
Substances:
Year: 2018 PMID: 30373571 PMCID: PMC6206633 DOI: 10.1186/s12903-018-0645-9
Source DB: PubMed Journal: BMC Oral Health ISSN: 1472-6831 Impact factor: 2.757
Fig. 1Illustration depicting the intra-pulpal pressure simulation apparatus used in this study
Fig. 2Means and Standard Deviations of the Micro-tensile bond strengths of the different groups at different storage periods in permanent teeth, Mega pascal (MPa). Within povidone iodine group (F = 0.746; p = 0.477), within chlorhexidine group and control group (F = 9.482, p < 0.001 and F = 46.036, p < 0.001, respectively)
Post-hoc test for resin-dentin micro-tensile bond strength in the chlorhexidine group
| Post-hoca | ||
|---|---|---|
| 24 h | 1 week | 0.386 |
| 1 week | 2 months | 0.021* |
| 2 months | 24 h | < 0.001* |
aBonferroni test
*Statistically significant at p < 0.05
Post-hoc test for resin-dentin micro-tensile bond strength in the control group
| Post-hoca | ||
|---|---|---|
| 24 h | 1 week | 0.049* |
| 1 week | 2 months | < 0.001* |
| 2 months | 24 h | < 0.001* |
aBonferroni Test
*Statistically significant at p < 0.05
Associations between storage time and failure mode in permanent teeth in each group
| Dentin surface pretreatment | Type of failure | Storage time | Total (%) | |||
|---|---|---|---|---|---|---|
| 24 h (%) | 1 week (%) | 2 months (%) | ||||
| Povidone-iodine | Adhesive failure | 38 (88.4) | 32 (82.1) | 26 (60.5) | 96 (76.8) | 0.007* |
| Cohesive in dentin | 0 (0) | 0 (0) | 4 (9.3) | 4 (3.2) | ||
| Cohesive in composite | 0 (0) | 4 (10.3) | 5 (11.6) | 9 (7.2) | ||
| Mixed failure | 5 (11.6) | 3 (7.7) | 8 (18.6) | 16 (12.8) | ||
| Total | 43 (100) | 39 (100) | 43 (100) | 125 (100) | ||
| Chlorhexidine | Adhesive failure | 36 (90.0) | 33 (84.6) | 24 (61.5) | 93 (78.8) | 0.013* |
| Cohesive in dentin | 0 (0) | 1 (2.6) | 1 (2.6) | 2 (1.7) | ||
| Cohesive in composite | 2 (5.0) | 0 (0) | 5 (12.8) | 7 (5.9) | ||
| Mixed failure | 2 (5.0) | 5 (12.8) | 9 (23.1) | 16 (13.6) | ||
| Total | 40 (100) | 39 (100) | 39 (100) | 118 (100) | ||
| Control | Adhesive failure | 37 (84.1) | 36 (81.8) | 30 (66.7) | 103 (77.4) | 0.053 |
| Cohesive in dentin | 3 (6.8) | 1 (2.3) | 0 (0) | 4 (3.0) | ||
| Cohesive in composite | 1 (2.3) | 3 (6.8) | 8 (17.8) | 12 (9.0) | ||
| Mixed failure | 3 (6.8) | 4 (9.1) | 7 (15.6) | 14 (10.5) | ||
| Total | 44 (100) | 44 (100) | 45 (100) | 133 (100) | ||
| Total | Adhesive failure | 111 (87.4) | 101 (82.8) | 80 (63.0) | 292 (77.7) | < 0.001* |
| Cohesive in dentin | 3 (2.4) | 2 (1.6) | 5 (3.9) | 10 (2.7) | ||
| Cohesive in composite | 3 (2.4) | 7 (5.7) | 18 (14.2) | 28 (7.4) | ||
| Mixed failure | 10 (7.9) | 12 (9.8) | 24 (18.9) | 46 (12.2) | ||
| Total | 127 (100) | 122 (100) | 127 (100) | 376 (100) | ||
+Fisher’s exact test
*Statistically significant at p < 0.05