Literature DB >> 9002807

Effect of disinfectants on the bond strength of composite to dentin.

J C Meiers1, L W Shook.   

Abstract

PURPOSE: To investigate the effect of two cavity disinfectants, a 2% chlorhexidine (Bisco) and a 0.11% iodine/potassium-iodide/copper sulfate solution (ORA-5), on the shear bond strength of composite to dentin mediated by the dentin bonding agents (DBA), Syntac and Tenure.
MATERIALS AND METHODS: The occlusal surfaces of 72 noncarious extracted human molar teeth were flattened to dentin using 500 grit sandpaper. They were randomly assigned (n = 12) to three groups within each DBA system: Bisco/Tenure, ORA-5/Tenure, Tenure, Bisco/Syntac, ORA-5/Syntac and Syntac. Dentin disinfectants were applied for 20 seconds and dried. DBA was applied following manufacturer's instructions. A hybrid resin composite (Tetric) was then bonded to all treated samples. The samples were thermocycled and tested in shear until failure. Fracture analysis was performed on dentin surfaces with both light and scanning electron microscopy. Shear bond strength data was analyzed using ANOVA, Student-Neuman-Keuls and Dunnett tests at P < 0.05.
RESULTS: Shear bond values (Mean +/- SD, MPa) were: Syntac control 14.3 +/- 2.0, Bisco/Syntac 8.1 +/- 4.9 and ORA-5/Syntac 5.7 +/- 5.1; Tenure control 15.0 +/- 1.9, Bisco/Tenure 14.2 +/- 3.0 and ORA-5/Tenure 13.9 +/- 3.7. The only significant difference found between disinfectant treatment groups and the control groups was with Syntac. Fracture surface analysis revealed that with Tenure most failures were cohesive in resin but with Syntac, the disinfected samples displayed adhesive failures.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9002807

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  18 in total

1.  Effect of Endodontic Irrigating Solutions on the Micro Push-out Bond Strength of a Fibre Glass Dowel.

Authors:  Olimpia Crispim da Silveira; Rodivan Bras da Silva; Fabio Roberto Dametto; Claudia Tavares Machado; Alex Jose Souza Dos Santos; Alessandro Leite Cavalcanti
Journal:  Acta Stomatol Croat       Date:  2014-03

2.  Evaluation of effect of three different dental unit waterline antimicrobials on the shear bond strength to dentin - An ex vivo study.

Authors:  Bv Sreenivasa Murthy; Kv Manjula; John V George; N Shruthi
Journal:  J Conserv Dent       Date:  2012-07

3.  Review of matrix metalloproteinases' effect on the hybrid dentin bond layer stability and chlorhexidine clinical use to prevent bond failure.

Authors:  Peter C Moon; Jared Weaver; Carol N Brooks
Journal:  Open Dent J       Date:  2010-07-20

4.  Effect of chlorhexidine cavity disinfection on microleakage in cavities restored with composite using a self-etching single bottle adhesive.

Authors:  Mamta Singla; Vivek Aggarwal; Narender Kumar
Journal:  J Conserv Dent       Date:  2011-10

5.  Shear bond strength of composite resin to dentin after application of cavity disinfectants - SEM study.

Authors:  Vivek Sharma; Poonam Rampal; Sukesh Kumar
Journal:  Contemp Clin Dent       Date:  2011-07

6.  Comparing the antibacterial activity of gaseous ozone and chlorhexidine solution on a tooth cavity model.

Authors:  Arife Kapdan; Nurhan Oztaş; Zeynep Sümer
Journal:  J Clin Exp Dent       Date:  2013-07-01

7.  Effect of a novel quaternary ammonium methacrylate polymer (QAMP) on adhesion and antibacterial properties of dental adhesives.

Authors:  Yasmine M Pupo; Paulo Vitor Farago; Jessica M Nadal; Luzia C Simão; Luís Antônio Esmerino; Osnara M M Gomes; João Carlos Gomes
Journal:  Int J Mol Sci       Date:  2014-05-20       Impact factor: 5.923

8.  Effect of 2% iodine disinfecting solution on bond strength to dentin.

Authors:  Nelson Renato Franca Alves da Silva; Christine S Calamia; Paulo G Coelho; Marcela Rocha de Oliveira Carrilho; Ricardo Marins de Carvalho; Page Caufield; Van P Thompson
Journal:  J Appl Oral Sci       Date:  2006-12       Impact factor: 2.698

9.  Effect of chlorhexidine on bonding durability of two self-etching adhesives with and without antibacterial agent to dentin.

Authors:  Fereshteh Shafiei; Armaghan Alikhani; Ali Asghar Alavi
Journal:  Dent Res J (Isfahan)       Date:  2013-11

10.  The effect of cavity disinfectants on the micro-shear bond strength of dentin adhesives.

Authors:  Dina Wafik Elkassas; Elham Mostafa Fawzi; Ahmed El Zohairy
Journal:  Eur J Dent       Date:  2014-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.