Literature DB >> 33679932

Reliability of Hand-Held Dynamometer for assessing Isometric Lumbar Muscles Strength in Asymptomatic Healthy Population.

Fahad Tanveer1, Syed Asadullah Arslan2, Haider Darain3, Ashfaq Ahmad4.   

Abstract

OBJECTIVE: To determine intra-rater and inter-rater reliability of hand-held dynamometer for assessing isometric lumbar muscle strength in asymptomatic healthy population.
METHODS: It was a cross-sectional study conducted at the department of physiotherapy, University of Lahore Teaching Hospital, Lahore, Pakistan, from July 2020 to August 2020 through non probability-purposive sampling technique. Thirty healthy subjects were tested at thirty-degree lumbar flexion and zero-degree lumbar extension positions. Two raters assessed isometric strength of lumbar flexor and extensor muscles, by a hand-held dynamometer. Strength was measured and recorded by each of the two raters and re-assessed after a week. Correlation and pairwise comparison were done between readings. ICC values were calculated for the assessment of isometric lumbar muscle strength using handheld dynamometer.
RESULTS: A total of 30 healthy subjects had participated with mean age of 22.84±1.21 years, height 174.33±6.83 cm, weight 68.58±5.08 kg and BMI 22.52±0.35. Findings showed an excellent intra-rater (ICC 2, k = 0.95 to 0.97) and inter-rater (ICC 2, k = 0.94 to 0.95) reliability.
CONCLUSIONS: Hand held dynamometer demonstrated an excellent intra- and inter-rater reliability for assessment of isometric lumbar muscles strength of healthy subject at clinical setting as it is simple to use, portable and cost-effective for the precise measurement of lumbar muscles strength. Copyright: © Pakistan Journal of Medical Sciences.

Entities:  

Keywords:  Lumbar region; Muscle strength dynamometer; Reliability

Year:  2021        PMID: 33679932      PMCID: PMC7931324          DOI: 10.12669/pjms.37.2.3621

Source DB:  PubMed          Journal:  Pak J Med Sci        ISSN: 1681-715X            Impact factor:   1.088


  18 in total

1.  Absolute reliability and concurrent validity of a novel electromechanical pulley dynamometer for measuring shoulder rotation isometric strength in asymptomatic subjects. Study conducted at Pontificia Universidad Católica, Santiago, Chile.

Authors:  Claudio Chamorro; Carlos De la Fuente; Jose Rubio; Christian Campos; Luis Javier Chirosa
Journal:  J Pak Med Assoc       Date:  2019-07       Impact factor: 0.781

2.  Deviating running kinematics and hamstring injury susceptibility in male soccer players: Cause or consequence?

Authors:  Joke Schuermans; Damien Van Tiggelen; Tanneke Palmans; Lieven Danneels; Erik Witvrouw
Journal:  Gait Posture       Date:  2017-06-27       Impact factor: 2.840

3.  Reliability and validity of trunk flexor and trunk extensor strength measurements using handheld dynamometry in a healthy athletic population.

Authors:  Cedric De Blaiser; Roel De Ridder; Tine Willems; Lieven Danneels; Philip Roosen
Journal:  Phys Ther Sport       Date:  2018-10-12       Impact factor: 2.365

4.  Normative reference values for strength and flexibility of 1,000 children and adults.

Authors:  Marnee J McKay; Jennifer N Baldwin; Paulo Ferreira; Milena Simic; Natalie Vanicek; Joshua Burns
Journal:  Neurology       Date:  2016-11-23       Impact factor: 9.910

5.  Impaired Core Stability as a Risk Factor for the Development of Lower Extremity Overuse Injuries: A Prospective Cohort Study.

Authors:  Cedric De Blaiser; Roel De Ridder; Tine Willems; Luc Vanden Bossche; Lieven Danneels; Philip Roosen
Journal:  Am J Sports Med       Date:  2019-04-29       Impact factor: 6.202

Review 6.  A Review of Field-Based Assessments of Neuromuscular Control and Their Utility in Male Youth Soccer Players.

Authors:  Paul J Read; Jon L Oliver; Mark B A De Ste Croix; Gregory D Myer; Rhodri S Lloyd
Journal:  J Strength Cond Res       Date:  2019-01       Impact factor: 3.775

7.  Validity and Reliability of Hand-Held Dynamometry for Abdominal Flexion Muscular Assessment.

Authors:  Brett D Tarca; Thomas P Wycherley; Anthony Meade; Paul Bennett; Katia E Ferrar
Journal:  J Sport Rehabil       Date:  2020-06-12       Impact factor: 1.931

8.  MEASURES OF HIP MUSCLE STRENGTH AND RATE OF FORCE DEVELOPMENT USING A FIXATED HANDHELD DYNAMOMETER: INTRA-TESTER INTRA-DAY RELIABILITY OF A CLINICAL SET-UP.

Authors:  Lasse Ishøi; Per Hölmich; Kristian Thorborg
Journal:  Int J Sports Phys Ther       Date:  2019-09

9.  Validity and test-retest reliability of a novel simple back extensor muscle strength test.

Authors:  Amy T Harding; Benjamin Kurt Weeks; Sean A Horan; Andrew Little; Steven L Watson; Belinda Ruth Beck
Journal:  SAGE Open Med       Date:  2017-02-10

10.  Reliability and validity of knee extensor strength measurements using a portable dynamometer anchoring system in a supine position.

Authors:  Kwan-Sik Sung; You Gyoung Yi; Hyung-Ik Shin
Journal:  BMC Musculoskelet Disord       Date:  2019-07-08       Impact factor: 2.362

View more
  3 in total

1.  Reliability of hand-held dynamometer in measuring gluteus medius isometric muscle strength in healthy population.

Authors:  Rabail Rani Soomro; Hossein Karimi; Syed Amir Gillani
Journal:  Pak J Med Sci       Date:  2022 May-Jun       Impact factor: 2.340

2.  Inter-rater reliability of pressure biofeedback unit among individuals with and without chronic low back pain.

Authors:  Muhammad Khan; Hamayun Zafar; Syed Amir Gilani
Journal:  Pak J Med Sci       Date:  2022 Mar-Apr       Impact factor: 2.340

3.  Effects of Knee Joint Angle and Contraction Intensity on the Triceps Surae Stiffness.

Authors:  Ming Lin; Weixin Deng; Hongying Liang; Suiqing Yu; Qin Xu; Chunlong Liu
Journal:  Front Bioeng Biotechnol       Date:  2022-06-22
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.