| Literature DB >> 30347742 |
Joost Nelis1, Christopher Elliott2, Katrina Campbell3.
Abstract
A human mission to Mars can be viewed as the apex of human technological achievement. However, to make this dream a reality several obstacles need to be overcome. One is devising practical ways to safeguard the crew health during the mission through the development of easy operable and compact sensors. Lately, several smartphone-based sensing devices (SBDs) with the purpose to enable the immediate sensitive detection of chemicals, proteins or pathogens in remote settings have emerged. In this critical review, the potential to piggyback these systems for in situ analysis in space has been investigated on application of a systematic keyword search whereby the most relevant articles were examined comprehensively and existing SBDs were divided into 4 relevant groups for the monitoring of crew health during space missions. Recently developed recognition elements (REs), which could offer the enhanced ability to tolerate those harsh conditions in space, have been reviewed with recommendations offered. In addition, the potential use of cell free synthetic biology to obtain long-term shelf-stable reagents was reviewed. Finally, a synopsis of the possibilities of combining novel SBD, RE and nanomaterials to create a compact sensor-platform ensuring adequate crew health monitoring has been provided.Entities:
Keywords: analysis; biosensor; health; smartphone; space
Mesh:
Year: 2018 PMID: 30347742 PMCID: PMC6316803 DOI: 10.3390/bios8040096
Source DB: PubMed Journal: Biosensors (Basel) ISSN: 2079-6374
Figure 1Classification of relevant SBD related literature. A pie chart showing the classification of the 148 articles kept for thorough analyses after the keyword searches. Groups (outer circle) are divided into subgroups (inner pie chart). Percentages indicate percentage of articles presenting the group or subgroup in relation to the total amount of articles kept for analyses.
A list of SBDs developed to monitor general health features relevant for space missions.
| Target and Device Working Conditions | Detection Method | Pros and Cons |
|---|---|---|
| Hemolysis in blood [ | Colorimetric detection of free hemoglobin levels in plasma. Plasma is imaged and image-analyses is used to determine the amount of free hemoglobin levels present. | Pro: fast (10 min), cheap (few dollar), and relevant (astronaut anemia can be measured) |
| Con: Blood separation based on gravitation in capillary | ||
| Cell density detection [ | Magnetic levitation. Cells in a capillary filled with a paramagnetic medium are placed between 2 rare earth magnets and their levitation position is determined solely by their density. | Pro: Fast and facile identification of astronaut anemia and other diseases that evoke cell density changes |
| Con: Proof of principle only | ||
| Non-contact vital sign detection such as sleep apnea, pulse wave velocity measurements and respiration monitoring [ | Doppler radar sensor. Integration of demodulation techniques and miniaturization (System on chip) to enable SBD detection. | Pro: basic vital signals can be remotely measured and analyzed |
| Con: Experimental and not robust, sensitive for noise from movement | ||
| Tidal volume, V(T), estimator [ | Video analyses of chest movement | Pro: non-invasive monitoring of lung volume |
| Con: Other simple and more direct methods exist as well | ||
| Mobile cell migration assay for neutrophil and cancer cell chemotaxis [ | Test kit consists of a smartphone-imaging platform using microfluidic channels, LED illumination, emission filters and image analyses. | Pro: Neutrophil chemotaxis can be tested directly from a drop of blood. |
| Con: System still at proof of principle stage | ||
| Detection of chronic obstructive pulmonary diseases [ | Resistance relative humidity sensor. Nanoparticle doped paper (NDP) resistance was measured during NDP exposure to breathe channeled through mouthpiece. | Pro: Quick way to detect chronic obstructive pulmonary diseases |
| Con: System still at proof of principle stage | ||
| Quantitative clinical method for total protein, albumin, and hematocrit analysis [ | Colorimetric detection on polyester-toner, laser printed, microfluidic disks. Test enables both whole blood separation and component detection using SBD image analyses. | Pro: System is quick and fully integrated. |
| Con: The system is complex (production costs) | ||
| Determine water-fat ratio in the body [ | Bioelectrical impedance analysis using a miniature multi-frequency impedance spectrometer for whole body impedance measurements. | Pro: Non-invasive, rapid and accurate |
| Con: System still at proof of principle stage | ||
| Determine hemoglobin concentration and detect HIV virus [ | Microfluidic device with colorimetric detection to determine hemoglobin concentration and absorbance (silver enhanced precipitation of colloid gold) for HIV related antibody detection. | Pro: System is simple does not require expertise for use |
| Con: System still at proof of principle stage | ||
| Urinary tract infection detection [ | Colorimetric detection using image analyses. Device needs reference values for training set. Device is equipped with auto-localization to classify and detect ± 100 spots of 12 biomarkers simultaneously | Pro: multiplex detection of 12 biomarkers within one picture |
| Con: semi-quantitative only, varying illumination can effect results |
Figure 2Schematic representation of a multiplex system for pathogen detection in air. The system depicted here follows the same principle as suggested in [100]. To this principle we added a presentation of enhanced aerodynamic reach as developed by [102] in combination with a simple microfluidic system to reach multiplex detection of several targets (as presented by pink, red and blue color particles).
A list of the SBDs that were not classified in any group since they have targets from various groups. Targets, detection methods, advantages and limitations of each SBD are highlighted.
| Target | Method | Advantages | Limitation | Reference |
|---|---|---|---|---|
| Inhibition of DNA-paramagnetic silica bead aggregation, otherwise induced in longer strand DNA mixtures, by centrifugation after LAMP (a). | Single copy detection of DNA using simple device replacing fluorescent detection with simple aggregation assay measurable directly with SBD camera. | No guaranty regarding specificity in assay. Any short DNA amplicons will shield the beads from aggregation | [ | |
| Water born parasites, CD4+ T-Cells are detected in an 81 mm2 wide view with 10 µm resolution. An experimental protocol is included. | Fluorescent imaging flow cytometry using microfluidics, LED excitation and time-lapse video recording using the digital frames for cell counting. Also wide view microscopy using the smartphone camera is demonstrated. | Wide field of view for good diagnostics at low copy number and mobile cell counting. | Target must be fluorescently labeled prior to analyses | [ |
| Multiplex (384) lateral flow protein micro array for clinically relevant biomarkers. Accuracy was 98% compared to established glass microarray for 26 antigen specific antibodies. | Paper based lateral flow protein microarray using biotin conjugated secondary Abs and anti-biotin coated GNPs | High multiplexing possibility and sensitive detection (30 ng/mL) in 10 min. | Multiple amplification steps can impede accurate quantification. High multiplexing can reduce signal to noise ratio. | [ |
| DNA or RNA detection of multiple analytes in diverse matrixes (blood and water) using various microfluidic devices is described. | Microchip combining filtration, cell lysis, isothermal amplification and fluorescent detection for virus and bacteria. | Sensitivity and specificity comparable to conventional bench top methods | Complex matrix can impede enzyme assisted isothermal amplification | [ |
| Human C-reactive protein (CRP) detection by sandwich ELISA, HRP detection for direct ELISA and BCA total protein estimation assays were performed for the SBD and compared to conventional microtiter plate readers (MTPR). | Standard ELISA tests read out by smartphone camera. SBD showed equal performance to conventional MTPR for LOD, LOQ, dynamic range, sensitivity and precision for all 3 assays. | Simple application using already existing established methods with low cost and miniaturized material. | Analyses requires same time frame and expertise as conventional ELISA | [ |
| Carcinoembryonic antigen (CEA) (1) and (2), adenosine triphosphate (ATP). LOD for CEA was 6.1 pg/mL. LOD for ATP was 11 µM. Normal range of CEA is < 2.5 ng/mL and ATP roughly 1 mM. Thus mentioned LODs show usefulness’ of the device. | Inhibition of peroxide induced etching of nanoprisms and color change by presence of more Ab-NPs at high target concentrations (1). | Simple system using the ambient light sensor to detect the color changes in the suspension. | Complicated setup. Especially using dsDNA which dissociates to ssDNA (for GNP stabilization) and aptamer-target complex. The functioning of the system might be very dependent on the salt concentration in the matrix | [ |
| Relative particle number densities determined in food (fat droplets in milk, yeast in water) and medical (RBCs in whole blood) matrixes. | ELS (c) with diode laser is used to create angular resolved scattering patterns which are imaged by the SBD camera. Mie theory is then used to calculate particle size. | Cheap determination of size distribution of particles in blood, yeast and milk. | Poor accuracy (±20 nm) and at proof of principle stage. | [ |
(a) Loop mediated isothermal amplification. (b) An inhibition assay where dsDNA (an ATP-aptamer and its complement) are incubated with ATP at 37 degree. ATP presence ensures structural change of the aptamer and avoids reformation of dsDNA thus preventing salt induced aggregation. (c) Elastic light scattering.
A description of REs which illustrates the advantages and limitations of each.
| RE | Description | Advantage | Limitations | Reference |
|---|---|---|---|---|
| Antibody | Specialized immune protein capable to recognize its antigen via a key-lock principle. Antibody antigen binding is based on Van der waals, hydrophobic and hydrogen bonds making it quite a stable complex. | Highly developed protocols exist, LOD often in pM range. Antibodies can often operate in quite varying conditions (pH, Salinity, complex matrix) and many protocols exist, making antibody based detection often the method of choice. | Production cost of monoclonal Ab is high. Protein can degrade limiting long-term storage. Setting up a reliable hybridoma line for monoclonal antibody is costly and can take years. Antibodies are primarily produced in animals. | [ |
| Aptamer | Oligonucleotide designed to specifically bind its target (often upon conformation change) via subsequent systematic selection of the best binders available in a randomized pool of oligonucleotides. This selection process is called SELEX (systematic evolution by exponential enrichment). Many varieties of the process exist. | Developed protocols exist, LOD in the nm and even pM range is reported. Production is synthetic and cheaper as antibodies. Aptamer-target complexation often results in a significant conformational change of the aptamer which can be used as a label-free sensing principle. | Often binding specificity is sensitive to salt concentration. Degradation sensitive due to nucleases, hard to use in complex matrix. | [ |
| MIP | Polymers with functional groups capable to interact with target functional groups are polymerized around the target. Next the target is eluded leaving a functionalized pocket behind to act with the target via a key-lock interaction principle | MIPs are cheap to produce if the target is not expensive. MIPs are very stable, leading to long shelf life. Detection limits in the pM range are reported but less common. | Washing out the template molecule can prove difficult. Target affinity can change between batches. Higher amounts of template is needed which can increase production costs. | [ |
| Enzyme activity inhibition | The ability of an enzyme to catalyze its reaction is inhibited by the presence of a pollutant. The method is often used to detect organophosphorus pesticides. In such assays the enzymatic catalyzed conversion of a substrate to a colored product is often measured. Absence or reduction of the intensity of reaction indicates enzyme inhibition. | OPA (a), OPAA (b) and ACHE (c) enzyme inhibition assays are cheap and fast tests ideal for on-site screening. Especially OPH and OPAA enzymes are good candidates since they allow sensitive 1 step only detection. Moreover, genetically engineered recombinant enzymes of these groups exist and result in higher sensitivity. | Enzymatic activity can be reduced by many different compounds. Thus the specificity of this system can be compromised if real samples are used. Work remains to be done to further engineer OP and OPAA enzymes for optimal results. | [ |
| Enzymatic substrate conversion | Enzymatic catalyzes of a compound leading to direct or indirect electron transport to an electrode used in electrochemical detection or conversion to a fluorochrome or colored compound for optical detection. | A wide variety of sensors based on this principle exist some of which like glucose sensors have proven to be fast, sensitive, low cost and reliable. | The inhibition of catalytic activity can lead to false negatives. Especially in matrices from patients containing ROS (d) and or inflamed tissues containing proteases capable to degrade the enzymes. | [ |
| Riboswitches | RNA based system comprising 2 domains, a recognition domain (aptamer) and signaling domain. Upon recognition the conformational change frees an area of the signaling domain that can inhibit or promote translation of a protein or transcription of a reporter gene, triggering a fluorescent response. In some cases fluorescent response even occurs directly upon binding the analyte. These riboswitches are called fluorogenic riboswitches. | This system is very effective to enable small molecule induced gene regulation and can be used with synthetic aptamers to create fluorescent RNA based biosensors as internal validation for CBBs. Moreover, synthesis is synthetic and cheap compared to antibodies. | The best functioning riboswitches are prokaryotic. They will need to be adapted to use in eukaryotic cells to prevent rapid degradation of the RNA. For this non-natural nucleic acids, equally used for aptamer construction, might proof useful. | [ |
| Affibodies | Synthetically constructed peptide scaffolds combined with a specific peptide sequence used as the RE. The Scaffold sequence (around 6.5 kDa) contains no cysteine and often stays the same. The variable region classically contains 13 amino acids and can be specifically engineered for a given target. | Smaller then antibodies thus closer to surface of transduction element leading to low LODs. Scaffold can be engineered to allow orientated immobilization. Absence of cysteine avoids artificial sulfur-bridge formation. | The method is relatively undeveloped. Some initial successes are booked but more research is needed. | [ |
| CBBs | Living cells are integrated in the sensor. Their shape change, cell membrane damage or dead caused by interaction with the target are reported through optical or electrochemical detection. | CBBs have the unique ability to offer a measurable response to a pollutant related to actual physiologic responses of the subject to the substance. | The cells must be kept alive to function making long-term storage difficult. Many structurally different compounds can cause a similar response making downstream identification complex. | [ |
(a) OPH is organophosphorus hydrolase. (b) OPAA is organophosphorus acid anhydrolase. (c) ACHE is acetylcholinesterase. (d) ROS is reactive oxygen species.
Figure 3Novel recognition elements (REs). (A) This Schematic shows Apta-MIP hybrid fabrication steps where the aptamer is first immobilized on a gold surface after which the target is added. Next electropolymerization is followed by a washing step to produce the final hybrid; (B) Solid phase MIP production. The principle of solid phase MIP production starts with the immobilization of the target and ends with stringent washing to eluate the high affinity MIPs after whereby step 2 can be repeated several times; (C) A schematic showing the principle of enzyme free translation of polymers. The system that can be used to achieve the enzyme free translation of polymers carrying a pool of various side chains (here methacrylic acid (MAA) polyethylenglycol (PEG), 4-vinylpyridine (4-VP) and some amino acids with varying chirality are shown but others can be used).
Figure 4The galactic SBD. This figure shows a futuristic SBD that incorporates novel sensing technology with synthetic REs directly into the smartphone as well as using an add-on device equipped with interchangeable microfluidic cassettes. Possible uses and basic functioning mechanisms of these sensors are indicated.