Literature DB >> 21774454

Optofluidic fluorescent imaging cytometry on a cell phone.

Hongying Zhu1, Sam Mavandadi, Ahmet F Coskun, Oguzhan Yaglidere, Aydogan Ozcan.   

Abstract

Fluorescent microscopy and flow cytometry are widely used tools in biomedical sciences. Cost-effective translation of these technologies to remote and resource-limited environments could create new opportunities especially for telemedicine applications. Toward this direction, here we demonstrate the integration of imaging cytometry and fluorescent microscopy on a cell phone using a compact, lightweight, and cost-effective optofluidic attachment. In this cell-phone-based optofluidic imaging cytometry platform, fluorescently labeled particles or cells of interest are continuously delivered to our imaging volume through a disposable microfluidic channel that is positioned above the existing camera unit of the cell phone. The same microfluidic device also acts as a multilayered optofluidic waveguide and efficiently guides our excitation light, which is butt-coupled from the side facets of our microfluidic channel using inexpensive light-emitting diodes. Since the excitation of the sample volume occurs through guided waves that propagate perpendicular to the detection path, our cell-phone camera can record fluorescent movies of the specimens as they are flowing through the microchannel. The digital frames of these fluorescent movies are then rapidly processed to quantify the count and the density of the labeled particles/cells within the target solution of interest. We tested the performance of our cell-phone-based imaging cytometer by measuring the density of white blood cells in human blood samples, which provided a decent match to a commercially available hematology analyzer. We further characterized the imaging quality of the same platform to demonstrate a spatial resolution of ~2 μm. This cell-phone-enabled optofluidic imaging flow cytometer could especially be useful for rapid and sensitive imaging of bodily fluids for conducting various cell counts (e.g., toward monitoring of HIV+ patients) or rare cell analysis as well as for screening of water quality in remote and resource-poor settings.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21774454      PMCID: PMC3263930          DOI: 10.1021/ac201587a

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  22 in total

1.  A microfabricated electrical differential counter for the selective enumeration of CD4+ T lymphocytes.

Authors:  Nicholas N Watkins; Supriya Sridhar; Xuanhong Cheng; Grace D Chen; Mehmet Toner; William Rodriguez; Rashid Bashir
Journal:  Lab Chip       Date:  2011-02-01       Impact factor: 6.799

2.  Fluorescence spectrometer-on-a-fluidic-chip.

Authors:  Oliver Schmidt; Michael Bassler; Peter Kiesel; Clifford Knollenberg; Noble Johnson
Journal:  Lab Chip       Date:  2007-03-27       Impact factor: 6.799

3.  A microchip approach for practical label-free CD4+ T-cell counting of HIV-infected subjects in resource-poor settings.

Authors:  Xuanhong Cheng; Daniel Irimia; Meredith Dixon; Joshua C Ziperstein; Utkan Demirci; Lee Zamir; Ronald G Tompkins; Mehmet Toner; William R Rodriguez
Journal:  J Acquir Immune Defic Syndr       Date:  2007-07-01       Impact factor: 3.731

Review 4.  Telemedicine and teledermatology: Past, present and future.

Authors:  Elisabeth M T Wurm; Rainer Hofmann-Wellenhof; Robert Wurm; Hans Peter Soyer
Journal:  J Dtsch Dermatol Ges       Date:  2007-11-12       Impact factor: 5.584

5.  Feasibility and acceptance of telemedicine for wound care in patients with chronic leg ulcers.

Authors:  R Hofmann-Wellenhof; W Salmhofer; B Binder; A Okcu; H Kerl; H P Soyer
Journal:  J Telemed Telecare       Date:  2006       Impact factor: 6.184

6.  A microfluidic device for practical label-free CD4(+) T cell counting of HIV-infected subjects.

Authors:  Xuanhong Cheng; Daniel Irimia; Meredith Dixon; Kazuhiko Sekine; Utkan Demirci; Lee Zamir; Ronald G Tompkins; William Rodriguez; Mehmet Toner
Journal:  Lab Chip       Date:  2006-11-24       Impact factor: 6.799

Review 7.  Poly(dimethylsiloxane) as a material for fabricating microfluidic devices.

Authors:  J Cooper McDonald; George M Whitesides
Journal:  Acc Chem Res       Date:  2002-07       Impact factor: 22.384

8.  Evaluation of a new point of care automated complete blood count (CBC) analyzer in various clinical settings.

Authors:  L V Rao; Björn A Ekberg; Diane Connor; Felice Jakubiak; Guy M Vallaro; Michael Snyder
Journal:  Clin Chim Acta       Date:  2007-12-14       Impact factor: 3.786

9.  Integration of semiconductor quantum dots into nano-bio-chip systems for enumeration of CD4+ T cell counts at the point-of-need.

Authors:  Jesse V Jokerst; Pierre N Floriano; Nicolaos Christodoulides; Glennon W Simmons; John T McDevitt
Journal:  Lab Chip       Date:  2008-11-05       Impact factor: 6.799

10.  A microchip CD4 counting method for HIV monitoring in resource-poor settings.

Authors:  William R Rodriguez; Nicolaos Christodoulides; Pierre N Floriano; Susan Graham; Sanghamitra Mohanty; Meredith Dixon; Mina Hsiang; Trevor Peter; Shabnam Zavahir; Ibou Thior; Dwight Romanovicz; Bruce Bernard; Adrian P Goodey; Bruce D Walker; John T McDevitt
Journal:  PLoS Med       Date:  2005-07-19       Impact factor: 11.069

View more
  84 in total

Review 1.  Inorganic Complexes and Metal-Based Nanomaterials for Infectious Disease Diagnostics.

Authors:  Christine F Markwalter; Andrew G Kantor; Carson P Moore; Kelly A Richardson; David W Wright
Journal:  Chem Rev       Date:  2018-12-04       Impact factor: 60.622

2.  Microfluidic diagnostics for the developing world.

Authors:  Xiaole Mao; Tony Jun Huang
Journal:  Lab Chip       Date:  2012-03-12       Impact factor: 6.799

3.  Handheld Fluorescence Microscopy based Flow Analyzer.

Authors:  Manish Saxena; Nitin Jayakumar; Sai Siva Gorthi
Journal:  J Fluoresc       Date:  2015-12-29       Impact factor: 2.217

4.  Image stacking approach to increase sensitivity of fluorescence detection using a low cost complementary metal-oxide-semiconductor (CMOS) webcam.

Authors:  Joshua Balsam; Hugh Alan Bruck; Yordan Kostov; Avraham Rasooly
Journal:  Sens Actuators B Chem       Date:  2012       Impact factor: 7.460

5.  Albumin testing in urine using a smart-phone.

Authors:  Ahmet F Coskun; Richie Nagi; Kayvon Sadeghi; Stephen Phillips; Aydogan Ozcan
Journal:  Lab Chip       Date:  2013-11-07       Impact factor: 6.799

6.  Integrated rapid-diagnostic-test reader platform on a cellphone.

Authors:  Onur Mudanyali; Stoyan Dimitrov; Uzair Sikora; Swati Padmanabhan; Isa Navruz; Aydogan Ozcan
Journal:  Lab Chip       Date:  2012-05-17       Impact factor: 6.799

7.  Optofluidics incorporating actively controlled micro- and nano-particles.

Authors:  Aminuddin A Kayani; Khashayar Khoshmanesh; Stephanie A Ward; Arnan Mitchell; Kourosh Kalantar-Zadeh
Journal:  Biomicrofluidics       Date:  2012-07-18       Impact factor: 2.800

8.  Smart-phone based computational microscopy using multi-frame contact imaging on a fiber-optic array.

Authors:  Isa Navruz; Ahmet F Coskun; Justin Wong; Saqib Mohammad; Derek Tseng; Richie Nagi; Stephen Phillips; Aydogan Ozcan
Journal:  Lab Chip       Date:  2013-08-12       Impact factor: 6.799

9.  Acoustofluidic devices controlled by cell phones.

Authors:  Hunter Bachman; Po-Hsun Huang; Shuaiguo Zhao; Shujie Yang; Peiran Zhang; Hai Fu; Tony Jun Huang
Journal:  Lab Chip       Date:  2018-01-30       Impact factor: 6.799

Review 10.  Cellphone-based devices for bioanalytical sciences.

Authors:  Sandeep Kumar Vashist; Onur Mudanyali; E Marion Schneider; Roland Zengerle; Aydogan Ozcan
Journal:  Anal Bioanal Chem       Date:  2013-11-28       Impact factor: 4.142

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.