Literature DB >> 30341735

Novel In Vitro Test Systems and Insights for Transcatheter Mitral Valve Design, Part I: Paravalvular Leakage.

Eric L Pierce1, Vahid Sadri1, Beatrice Ncho1, Keshav Kohli1, Siddhi Shah1, Ajit P Yoganathan2.   

Abstract

While transcatheter mitral valve (TMV) replacement technology has great clinical potential for surgically inoperable patients suffering from mitral regurgitation, no TMV has yet achieved regulatory approval. The diversity of devices currently under development reflects a lack of consensus regarding optimal design approaches. In Part I of this two-part study, a test system was developed for the quantification of paravalvular leakage (PVL) following deployment of a TMV or TMV-like device in pressurized, explanted porcine hearts (N = 7). Using this system, PVL rate was investigated as a function of steady trans-mitral pressure (ΔP), TMV shape, and TMV-annular oversizing, using a series of "mock TMV plug" devices. Across all devices, PVL was found to approximately trend with the square of ΔP. PVL rates were approximately 0-15 mL/s under hypotensive pressure, 10-40 mL/s under normotension, and 30-85 mL/s under severe hypertension. D-shaped devices significantly reduced PVL vs. circular devices; however, this effect was diminished upon oversizing to the annulus by 6 mm inter-trigonal distance. In conclusion, this steady pressure, in vitro test system was effective to compare PVL performance across TMV-like designs. PVL exhibited complex dynamics in terms of its response to transvalvular pressure and TMV profile.

Entities:  

Keywords:  Device–tissue interaction; Flow rate; In Vitro; Medical device; Mitral valve; Paravalvular leakage; Test method; Transcatheter; Transcatheter mitral valve implantation; Transcatheter mitral valve replacement

Mesh:

Year:  2018        PMID: 30341735      PMCID: PMC6344268          DOI: 10.1007/s10439-018-02154-4

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  31 in total

1.  Double-crowned valved stents for off-pump mitral valve replacement.

Authors:  Liang Ma; Piergiorgio Tozzi; Christoph H Huber; Steven Taub; Gabrielle Gerelle; Ludwig K von Segesser
Journal:  Eur J Cardiothorac Surg       Date:  2005-08       Impact factor: 4.191

Review 2.  The current state of in-vivo pre-clinical animal models for heart valve evaluation.

Authors:  Robert P Gallegos; Pavel J Nockel; Andrew L Rivard; Richard W Bianco
Journal:  J Heart Valve Dis       Date:  2005-05

3.  Two-year outcomes after transcatheter or surgical aortic-valve replacement.

Authors:  Susheel K Kodali; Mathew R Williams; Craig R Smith; Lars G Svensson; John G Webb; Raj R Makkar; Gregory P Fontana; Todd M Dewey; Vinod H Thourani; Augusto D Pichard; Michael Fischbein; Wilson Y Szeto; Scott Lim; Kevin L Greason; Paul S Teirstein; S Chris Malaisrie; Pamela S Douglas; Rebecca T Hahn; Brian Whisenant; Alan Zajarias; Duolao Wang; Jodi J Akin; William N Anderson; Martin B Leon
Journal:  N Engl J Med       Date:  2012-03-26       Impact factor: 91.245

4.  Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the Medtronic CoreValve bioprosthesis.

Authors:  Mohammad A Sherif; Mohamed Abdel-Wahab; Björn Stöcker; Volker Geist; Doreen Richardt; Ralph Tölg; Gert Richardt
Journal:  J Am Coll Cardiol       Date:  2010-11-09       Impact factor: 24.094

5.  Aortic valve calcium scoring is a predictor of significant paravalvular aortic insufficiency in transapical-aortic valve implantation.

Authors:  Martin Haensig; Lukas Lehmkuhl; Ardawan Julian Rastan; Joerg Kempfert; Chirojit Mukherjee; Matthias Gutberlet; David Michael Holzhey; Friedrich Wilhelm Mohr
Journal:  Eur J Cardiothorac Surg       Date:  2012-01-12       Impact factor: 4.191

6.  Burden of valvular heart diseases: a population-based study.

Authors:  Vuyisile T Nkomo; Julius M Gardin; Thomas N Skelton; John S Gottdiener; Christopher G Scott; Maurice Enriquez-Sarano
Journal:  Lancet       Date:  2006-09-16       Impact factor: 79.321

Review 7.  Osmotic swelling and residual stress in cardiovascular tissues.

Authors:  Yoram Lanir
Journal:  J Biomech       Date:  2012-01-10       Impact factor: 2.712

8.  Different clinical outcome of paravalvular leakage after aortic or mitral valve replacement.

Authors:  In Jeong Cho; Jeonggeun Moon; Chi Young Shim; Yangsoo Jang; Namsik Chung; Byung-Chul Chang; Jong-Won Ha
Journal:  Am J Cardiol       Date:  2011-01-15       Impact factor: 2.778

9.  What are the characteristics of patients with severe, symptomatic, mitral regurgitation who are denied surgery?

Authors:  Mariana Mirabel; Bernard Iung; Gabriel Baron; David Messika-Zeitoun; Delphine Détaint; Jean-Louis Vanoverschelde; Eric G Butchart; Philippe Ravaud; Alec Vahanian
Journal:  Eur Heart J       Date:  2007-03-09       Impact factor: 29.983

10.  Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence.

Authors:  Delphine Détaint; Laurent Lepage; Dominique Himbert; Eric Brochet; David Messika-Zeitoun; Bernard Iung; Alec Vahanian
Journal:  JACC Cardiovasc Interv       Date:  2009-09       Impact factor: 11.195

View more
  3 in total

1.  Novel In Vitro Test Systems and Insights for Transcatheter Mitral Valve Design, Part II: Radial Expansion Forces.

Authors:  Eric L Pierce; Keshav Kohli; Beatrice Ncho; Vahid Sadri; Charles H Bloodworth; Fiona E Mangan; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2018-10-17       Impact factor: 3.934

2.  Mechanical Response Changes in Porcine Tricuspid Valve Anterior Leaflet Under Osmotic-Induced Swelling.

Authors:  Samuel D Salinas; Margaret M Clark; Rouzbeh Amini
Journal:  Bioengineering (Basel)       Date:  2019-08-15

Review 3.  Heart Valve Biomechanics: The Frontiers of Modeling Modalities and the Expansive Capabilities of Ex Vivo Heart Simulation.

Authors:  Matthew H Park; Yuanjia Zhu; Annabel M Imbrie-Moore; Hanjay Wang; Mateo Marin-Cuartas; Michael J Paulsen; Y Joseph Woo
Journal:  Front Cardiovasc Med       Date:  2021-07-08
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.