PURPOSE: Integrated parallel reception, excitation, and shimming (iPRES) coil arrays allow radio-frequency currents and direct currents to flow in the same coils, which enables excitation/reception and localized B0 shimming with a single coil array. The purpose of this work was to improve their shimming performance by adding the capability to shim higher-order local B0 inhomogeneities that are smaller than the radio-frequency coil elements.
METHODS: A novel design was proposed in which each radio-frequency/shim coil element is divided into multiple direct current loops, each using an independent direct current current, to increase the number of magnetic fields available for shimming while maintaining the signal-to-noise ratio of the coil. This new design is termed iPRES(N), where N represents the number of direct current loops per radio-frequency coil element. Proof-of-concept phantom and human experiments were performed with an 8-channel body coil array to demonstrate its advantages over the original iPRES(1) design.
RESULTS: The average B0 homogeneity in various organs before shimming and after shimming with the iPRES(1) or iPRES(3) coil arrays was 0.24, 0.11, and 0.05 ppm, respectively. iPRES(3) thus reduced the B0 inhomogeneity by 53% and further reduced distortions in echo-planar images of the abdomen when compared with iPRES(1).
CONCLUSION: iPRES(N) can correct for localized B0 inhomogeneities more effectively than iPRES(1) with no signal-to-noise ratio loss, resulting in a significant improvement in image quality. Magn Reson Med 77:2077-2086, 2017.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  B0 shimming; abdomen; coil array; radio-frequency coil; shim coil

Mesh:

Year:  2016        PMID: 27174387      PMCID: PMC5107366          DOI: 10.1002/mrm.26267

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

Review 1.  Diffusion-tensor MRI: theory, experimental design and data analysis - a technical review.

Authors:  Peter J Basser; Derek K Jones
Journal:  NMR Biomed       Date:  2002 Nov-Dec       Impact factor: 4.044

2.  Multicoil Dixon chemical species separation with an iterative least-squares estimation method.

Authors:  Scott B Reeder; Zhifei Wen; Huanzhou Yu; Angel R Pineda; Garry E Gold; Michael Markl; Norbert J Pelc
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

3.  Dynamic shim updating on the human brain.

Authors:  Kevin M Koch; Scott McIntyre; Terence W Nixon; Douglas L Rothman; Robin A de Graaf
Journal:  J Magn Reson       Date:  2006-03-30       Impact factor: 2.229

4.  Dynamic shim updating: a new approach towards optimized whole brain shimming.

Authors:  A M Blamire; D L Rothman; T Nixon
Journal:  Magn Reson Med       Date:  1996-07       Impact factor: 4.668

5.  A new approach to shimming: the dynamically controlled adaptive current network.

Authors:  Chad T Harris; William B Handler; Blaine A Chronik
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

6.  Multicoil shimming of the mouse brain.

Authors:  Christoph Juchem; Peter B Brown; Terence W Nixon; Scott McIntyre; Douglas L Rothman; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2011-03-25       Impact factor: 4.668

7.  A 32-channel combined RF and B0 shim array for 3T brain imaging.

Authors:  Jason P Stockmann; Thomas Witzel; Boris Keil; Jonathan R Polimeni; Azma Mareyam; Cristen LaPierre; Kawin Setsompop; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2015-02-17       Impact factor: 4.668

8.  Integrated parallel reception, excitation, and shimming (iPRES).

Authors:  Hui Han; Allen W Song; Trong-Kha Truong
Journal:  Magn Reson Med       Date:  2013-04-29       Impact factor: 4.668

9.  Dynamic multi-coil shimming of the human brain at 7 T.

Authors:  Christoph Juchem; Terence W Nixon; Scott McIntyre; Vincent O Boer; Douglas L Rothman; Robin A de Graaf
Journal:  J Magn Reson       Date:  2011-07-23       Impact factor: 2.229

10.  Dynamic Shimming of the Human Brain at 7 Tesla.

Authors:  Christoph Juchem; Terence W Nixon; Piotr Diduch; Douglas L Rothman; Piotr Starewicz; Robin A de Graaf
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2010-07-06       Impact factor: 1.176

View more
  10 in total

1.  3D-MB-MUSE: A robust 3D multi-slab, multi-band and multi-shot reconstruction approach for ultrahigh resolution diffusion MRI.

Authors:  Iain P Bruce; Hing-Chiu Chang; Christopher Petty; Nan-Kuei Chen; Allen W Song
Journal:  Neuroimage       Date:  2017-07-18       Impact factor: 6.556

2.  Integrated radio-frequency/wireless coil design for simultaneous MR image acquisition and wireless communication.

Authors:  Dean Darnell; Jonathan Cuthbertson; Fraser Robb; Allen W Song; Trong-Kha Truong
Journal:  Magn Reson Med       Date:  2018-09-14       Impact factor: 4.668

3.  Adaptive integrated parallel reception, excitation, and shimming (iPRES-A) with microelectromechanical systems switches.

Authors:  Dean Darnell; Yixin Ma; Hongyuan Wang; Fraser Robb; Allen W Song; Trong-Kha Truong
Journal:  Magn Reson Med       Date:  2017-11-16       Impact factor: 4.668

Review 4.  Proton MR spectroscopy in the breast: Technical innovations and clinical applications.

Authors:  Reza Fardanesh; Maria Adele Marino; Daly Avendano; Doris Leithner; Katja Pinker; Sunitha B Thakur
Journal:  J Magn Reson Imaging       Date:  2019-03-07       Impact factor: 4.813

5.  An orthogonal shim coil for 3T brain imaging.

Authors:  Jiazheng Zhou; Jason P Stockmann; Nicolas Arango; Thomas Witzel; Klaus Scheffler; Lawrence L Wald; Fa-Hsuan Lin
Journal:  Magn Reson Med       Date:  2019-10-21       Impact factor: 4.668

Review 6.  In vivo B0 field shimming methods for MRI at 7T.

Authors:  Jason P Stockmann; Lawrence L Wald
Journal:  Neuroimage       Date:  2017-06-07       Impact factor: 6.556

7.  Analysis of coil element distribution and dimension for matrix gradient coils.

Authors:  Hongyan He; Shufeng Wei; Huixian Wang; Wenhui Yang
Journal:  MAGMA       Date:  2022-06-11       Impact factor: 2.310

8.  Interleaved 31 P MRS imaging of human frontal and occipital lobes using dual RF coils in combination with single-channel transmitter-receiver and dynamic B0 shimming.

Authors:  Byeong-Yeul Lee; Xiao-Hong Zhu; Myung Kyun Woo; Gregor Adriany; Scott Schillak; Wei Chen
Journal:  NMR Biomed       Date:  2017-10-26       Impact factor: 4.044

9.  Application of an integrated radio-frequency/shim coil technology for signal recovery in fMRI.

Authors:  Devin Willey; Dean Darnell; Allen W Song; Trong-Kha Truong
Journal:  Magn Reson Med       Date:  2021-07-20       Impact factor: 4.668

Review 10.  In vivo MR spectroscopy for breast cancer diagnosis.

Authors:  Uma Sharma; Naranamangalam Raghunathan Jagannathan
Journal:  BJR Open       Date:  2019-07-02
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.