Literature DB >> 30209591

Comparison of full-iodine conventional CT and half-iodine virtual monochromatic imaging: advantages and disadvantages.

Haruto Sugawara1,2, Shigeru Suzuki3, Yoshiaki Katada1, Takuya Ishikawa1, Rika Fukui1, Yuzo Yamamoto1, Osamu Abe2.   

Abstract

PURPOSE: To compare image quality of abdominal arteries between full-iodine-dose conventional CT and half-iodine-dose virtual monochromatic imaging (VMI).
MATERIALS AND METHODS: We retrospectively evaluated images of 21 patients (10 men, 11 women; mean age, 73.9 years) who underwent both full-iodine (600 mg/kg) conventional CT and half-iodine (300 mg/kg) VMI. For each patient, we measured and compared CT attenuation and the contrast-to-noise ratio (CNR) of the aorta, celiac artery, and superior mesenteric artery (SMA). We also compared CT dose index (CTDI). Two board-certified diagnostic radiologists evaluated visualisation of the main trunks and branches of the celiac artery and SMA in maximum-intensity-projection images. We evaluated spatial resolution of the two scans using an acrylic phantom.
RESULTS: The two scans demonstrated no significant difference in CT attenuation of the aorta, celiac artery, and SMA, but CNRs of the aorta and celiac artery were significantly higher in VMI (p = 0.011 and 0.030, respectively). CTDI was significantly higher in VMI (p = 0.024). There was no significant difference in visualisation of the main trunk of the celiac artery and SMA, but visualisation of the gastroduodenal artery, pancreatic arcade, branch of the SMA, marginal arteries, and vasa recta was significantly better in the conventional scan (p < 0.001). The calculated modular transfer function (MTF) suggested decreased spatial resolution of the half-iodine VMI.
CONCLUSION: Large-vessel depiction and CNRs were comparable between full-iodine conventional CT and half-iodine VMI images, but VMI did not permit clear visualisation of small arteries and required a larger radiation dose. KEY POINTS: ・Reducing the dose of iodine contrast medium is essential for chronic kidney disease patients to prevent contrast-induced nephropathy. ・In virtual monochromatic images at low keV, contrast of relatively large vessels is maintained even with reduced iodine load, but visibility of small vessels is impaired with decreased spatial resolution. ・We should be aware about the advantages and disadvantages associated with virtual monochromatic imaging with reduced iodine dose.

Entities:  

Keywords:  CT angiography; Iodine; Qualitative evaluation; Quantitative evaluation; Retrospective study

Mesh:

Substances:

Year:  2018        PMID: 30209591     DOI: 10.1007/s00330-018-5724-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  28 in total

1.  Impact of iterative reconstruction on CNR and SNR in dynamic myocardial perfusion imaging in an animal model.

Authors:  B M Gramer; D Muenzel; V Leber; A-K von Thaden; H Feussner; A Schneider; M Vembar; N Soni; E J Rummeny; A M Huber
Journal:  Eur Radiol       Date:  2012-07-03       Impact factor: 5.315

2.  Dose reduction by automatic exposure control in multidetector computed tomography: comparison between measurement and calculation.

Authors:  U Lechel; C Becker; G Langenfeld-Jäger; G Brix
Journal:  Eur Radiol       Date:  2008-11-06       Impact factor: 5.315

3.  Quantitative Measurements Versus Receiver Operating Characteristics and Visual Grading Regression in CT Images Reconstructed with Iterative Reconstruction: A Phantom Study.

Authors:  Kristin Jensen; Hilde Kjernlie Andersen; Örjan Smedby; Bjørn Helge Østerås; Anette Aarsnes; Anders Tingberg; Erik Fosse; Anne Catrine Martinsen
Journal:  Acad Radiol       Date:  2017-11-29       Impact factor: 3.173

4.  Acute lower intestinal bleeding: feasibility and diagnostic performance of CT angiography.

Authors:  Milagros Martí; José M Artigas; Gonzalo Garzón; Rodolfo Alvarez-Sala; Jorge A Soto
Journal:  Radiology       Date:  2011-11-14       Impact factor: 11.105

5.  Reduced iodine load at CT pulmonary angiography with dual-energy monochromatic imaging: comparison with standard CT pulmonary angiography--a prospective randomized trial.

Authors:  Ren Yuan; William P Shuman; James P Earls; Cameron J Hague; Hina A Mumtaz; Andrew Scott-Moncrieff; Jennifer D Ellis; John R Mayo; Jonathon A Leipsic
Journal:  Radiology       Date:  2011-11-14       Impact factor: 11.105

6.  Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT.

Authors:  Kazuhiro Matsumoto; Masahiro Jinzaki; Yutaka Tanami; Akihisa Ueno; Minoru Yamada; Sachio Kuribayashi
Journal:  Radiology       Date:  2011-02-17       Impact factor: 11.105

7.  Coronary artery disease: diagnostic accuracy of CT coronary angiography--a comparison of high and standard spatial resolution scanning.

Authors:  Gianluca Pontone; Erika Bertella; Saima Mushtaq; Monica Loguercio; Sarah Cortinovis; Andrea Baggiano; Edoardo Conte; Andrea Annoni; Alberto Formenti; Virginia Beltrama; Andrea Igoren Guaricci; Daniele Andreini
Journal:  Radiology       Date:  2014-02-08       Impact factor: 11.105

8.  Effectiveness of Adaptive Statistical Iterative Reconstruction for 64-Slice Dual-Energy Computed Tomography Pulmonary Angiography in Patients With a Reduced Iodine Load: Comparison With Standard Computed Tomography Pulmonary Angiography.

Authors:  Ji Won Lee; Geewon Lee; Nam Kyung Lee; Jin Il Moon; Yun Hye Ju; Young Ju Suh; Yeon Joo Jeong
Journal:  J Comput Assist Tomogr       Date:  2016 Sep-Oct       Impact factor: 1.826

Review 9.  Contrast-Induced Acute Kidney Injury.

Authors:  Peter A McCullough; James P Choi; Georges A Feghali; Jeffrey M Schussler; Robert M Stoler; Ravi C Vallabahn; Ankit Mehta
Journal:  J Am Coll Cardiol       Date:  2016-09-27       Impact factor: 24.094

Review 10.  Preoperative hepatic vascular evaluation with CT and MR angiography: implications for surgery.

Authors:  Dushyant Sahani; Aparna Mehta; Michael Blake; Srinivasa Prasad; Gordan Harris; Sanjay Saini
Journal:  Radiographics       Date:  2004 Sep-Oct       Impact factor: 5.333

View more
  3 in total

1.  Initial evidence of a 50% reduction of contrast media using digital variance angiography in endovascular carotid interventions.

Authors:  Viktor I Óriás; Dávid Szöllősi; Marcell Gyánó; Dániel S Veres; Sándor Nardai; Csaba Csobay-Novák; Balázs Nemes; János P Kiss; Krisztián Szigeti; Szabolcs Osváth; Péter Sótonyi; Zoltán Ruzsa
Journal:  Eur J Radiol Open       Date:  2020-11-17

2.  Enriched Au nanoclusters with mesoporous silica nanoparticles for improved fluorescence/computed tomography dual-modal imaging.

Authors:  Yifang Yuan; Ronghui Zhou; Ting Li; Shuang Qu; Hua Bai; Jiawu Liang; Xiaoxiao Cai; Bin Guo
Journal:  Cell Prolif       Date:  2021-02-25       Impact factor: 6.831

3.  Advantages and disadvantages of single-source dual-energy whole-body CT angiography with 50% reduced iodine dose at 40 keV reconstruction.

Authors:  Yoshifumi Noda; Fumihiko Nakamura; Noriyuki Yasuda; Toshiharu Miyoshi; Nobuyuki Kawai; Hiroshi Kawada; Fuminori Hyodo; Masayuki Matsuo
Journal:  Br J Radiol       Date:  2021-02-22       Impact factor: 3.039