Vincenzo Rago1,2, João Brito3, Pedro Figueiredo4, Thiago Carvalho5, Tiago Fernandes6, Pedro Fonseca7, António Rebelo8.
Abstract
The aim of this study was to analyze the concurrent validity, test⁻retest reliability, and capacity to detect changes of four different portable devices used to measure a wide range of neuromuscular parameters derived from countermovement jump (CMJ). An accelerometric device (Myotest), a jump mat (Ergojump), an optical device (Optojump), and a smartphone app (MyJump) were simultaneously examined for concurrent validity against gold-standard measures (motion-capture system and a force platform). Twenty-two CMJ-derived variables were collected from 15 healthy male subjects (n = 60 CMJs). Contraction time (CT) and eccentric duration (EccD) measurements obtained from the Myotest were moderately to largely associated with and not different from force platform measurements (r = 0.31 to 0.64, ES = 0.11 to 0.18) and showed moderate test-retest reliability (intraclass correlation coefficient (ICC) = 0.92 to 0.97, coefficient of variation (CV) = 3.8 to 8.0%). Flight time (FT) and jump height (JH) from Ergojump, Optojump, and MyJump showed moderate to strong associations with gold-standard measurements (r = 0.57 to 0.98) and good test⁻retest reliability (ICC = 0.54 to 0.97, CV = 1.8 to 4.2). However, all portable devices underestimated JH (ES = 1.25 to 2.75). Independent of the instrument used, the analyzed CMJ variables showed good capacity to detect changes (standard error of measurement (SEM) < smallest worthwhile change (SWC)), with the exception of rate of force and rate of power development parameters, which showed marginal capacity (SEM > SWC). The Myotest is preferable to measure temporal parameters during ground contact, whereas Ergojump, Optojump, and MyJump devices may be preferable to measure FT and JH, with the Optojump being the most accurate.Entities:
Keywords: force platform; measurements; motion analysis; neuromuscular assessment; reliability; validity
Year: 2018 PMID: 30200384 PMCID: PMC6162675 DOI: 10.3390/sports6030091
Source DB: PubMed Journal: Sports (Basel) ISSN: 2075-4663
Definitions of neuromuscular parameters adopted.
| Variables | Abbreviation | Unit of Measure | Definition |
|---|---|---|---|
|
| - | - | - |
| Total contraction time | CT | s | Total duration from jump initiation to take-off |
| Eccentric duration | EccD | s | Time period of the eccentric phase |
| Concentric duration | ConD | s | Time period of the concentric phase |
| Time to peak force | T2PF | s | Time period between jump start and peak force |
| Time to peak power | T2PP | s | Time period between jump start and peak power |
| Flight time | FT | s | Time period of zero force, corresponding to noncontact with the floor |
| Flight time to contraction time ratio | FT:CT | % | Ratio between flight time and contraction time |
| Peak velocity | PV | m∙s−1 | Highest jump velocity during the concentric phase |
| Minimum velocity | MinV | m∙s−1 | Lowest jump velocity during the eccentric phase |
| Velocity at peak power | V@PP | m∙s−1 | Velocity recorded at time point where peak power occurred |
| Jump height | JH | m | Highest height achieved during the jump |
|
| - | - | - |
| Peak force | PF | N∙kg−1 | Maximum force achieved during the concentric phase |
| Mean force | MF | - | Average force of the concentric phase |
| Maximum rate of eccentric force development | mREFD | N∙s−1∙kg−1 | Maximum force increase within a 30 ms window during the eccentric phase |
| Maximum rate of concentric force development | mRCFD | N∙s−1∙kg−1 | Maximum force increase within a 30 ms window during the concentric phase. |
| Force at zero velocity | F@0V | N∙kg−1 | Force exerted at the end of the countermovement where the jump transitions from eccentric to concentric movement |
| Peak power | PP | W∙kg−1 | Higher power value achieved during the jump |
| Mean power | MP | W∙kg−1 | Average power value obtained during the concentric phase |
| Maximum rate of power development | mRPD | W∙s−1∙kg−1 | Largest power increase within a 30 ms window during the concentric phase |
| Mean eccentric and concentric power over time | MEccConP | W∙kg−1∙s−1 | Power produced during both eccentric (converted to positive values) and concentric phases, divided by contraction duration |
| Total impulse | TI | N∙s−1 | Force exerted concentrically multiplied by the time taken concentrically |
| Relative net impulse | RNI | N∙s∙kg−1 | Impulse between the beginning of the concentric phase and the moment force reached weight level, minus the impulse equivalent to that of the propulsion-deceleration phase |
Descriptive values of countermovement jump (CMJ) kinematic variables obtained with different devices. Values are mean ± standard deviation (SD).
| Variable | MCAP | Force Platform | Myotest | Ergojump | Optojump | MyJump |
|---|---|---|---|---|---|---|
|
| ||||||
| CT (s) | - | 0.77 ± 0.16 | 0.76 ± 0.09 | - | - | - |
| EccD (s) | - | 0.50 ± 0.15 | 0.50 ± 0.08 | - | - | - |
| ConD (s) | - | 0.26 ± 0.02 | 0.26 ± 0.04 | - | - | - |
| T2PF (s) | - | 0.55 ± 0.17 | 0.60 ± 0.10 | - | - | - |
| T2PP (s) | - | 0.71 ± 0.16 | 0.67 ± 0.09 | - | - | - |
| FT (s) | - | 0.54 ± 0.03 | 0.49 ± 0.04 | 0.55 ± 0.06 | 0.53 ± 0.03 | 0.57 ± 0.03 |
| FT:CT (%) | - | 0.72 ± 0.16 | 0.66 ± 0.10 | - | - | - |
| PV (m∙s−1) | 3.04 ± 0.23 | - | 2.08 ± 0.39 | - | - | 1.42 ± 0.23 |
| MinV (m∙s−1) | −1.25 ± 0.16 | - | −1.08 ± 0.26 | - | - | - |
| V@PP (m∙s−1) | - | 2.47 ± 0.15 | 1.89 ± 0.34 | - | - | - |
| JH (m) | 0.46 ± 0.04 | - | 0.42 ± 0.04 | 0.38 ± 0.07 | 0.35 ± 0.04 | 0.41 ± 0.04 |
|
| ||||||
| PF (N∙kg−1) | - | 23.88 ± 1.99 | 22.23 ± 2.37 | - | - | - |
| MF (N∙kg−1) | - | 13.39 ± 1.24 | 11.96 ± 0.82 | - | - | - |
| mREFD (N∙s−1∙kg−1) | - | 136.88 ± 69.88 | 101.27 ± 36.22 | - | - | - |
| mRCFD (N∙s−1∙kg−1) | - | 29.37 ± 19.93 | 57.44 ± 23.82 | - | - | - |
| F@0V (N∙kg−1) | - | 23.16 ± 2.31 | 18.77 ± 3.30 | - | - | - |
| PP (W∙kg−1) | - | 36.01 ± 8.80 | 47.84 ± 10.17 | 46.18 ± 5.38 | 51.47 ± 3.80 | - |
| MP (W∙kg−1) | - | 28.66 ± 2.51 | 18.89 ± 5.17 | - | - | - |
| mRPD (W∙s−1∙kg−1) | - | 345.49 ± 81.79 | 301.08 ± 84.41 | - | - | - |
| MEccConP (W∙kg−1∙s−1) | - | 13.63 ± 2.29 | 9.14 ± 2.04 | - | - | - |
| TI (N∙s−1) | - | 197.00 ± 29.77 | 121.74 ± 47.34 | - | - | - |
| RNI (N∙s−1∙kg−1) | - | 2.61 ± 0.16 | 1.70 ± 0.40 | - | - | - |
MCAP, motion capture system; ConD, concentric duration; CT, total contraction time; EccD, eccentric duration; F@0V, force at zero velocity; FT, flight time; FT:CT, flight time to contraction time ratio; MP, mean power; MEccConP, mean eccentric and concentric power over time; MinV, minimum velocity; mRCFD, maximum rate of concentric force development; mRCED, maximum rate of eccentric force development; mRPD, maximum rate of power development; PF, peak force; PP, peak power; PV, peak velocity; RNI, relative net impulse; T2PF, time to peak force; T2PP, time to peak power; TI, total impulse; V@PP, velocity at peak power.
Figure 1Differences between gold-standard measurements and four portable devices in 22 neuromuscular parameters. Shaded area indicates trivial differences (ES < 0.2). ConD, concentric duration; CT, total contraction time; EccD, Eeccentric duration; ES, effect size; F@0V, force at zero velocity; FT, flight time; FT:CT, flight time to contraction time ratio; ICC, intraclass correlation coefficient; MF, mean force; MP, mean power; MEccConP, mean eccentric and concentric power over time; MinV, minimum velocity; mRCFD, maximum rate of concentric force development; mREFD, maximum rate of eccentric force development; mRPD, maximum rate of power development; PF, peak force; PP, peak power; PV, peak velocity; RNI, relative net impulse; T2PF, time to peak force; T2PP, time to peak power; TI, total impulse; V@PP, velocity at peak power. Gold standard is a motion capture system for PV, MinV, and JH, and force platform for all remaining variables.
Figure 2Correlations between gold standard measurements and four portable devices in 22 neuromuscular parameters. Filled gray area indicates no significant correlation (r < 0.1). Shaded space indicates almost perfect correlation (r ≥ 0.9). ConD, concentric duration; CT, total contraction time; EccD, eccentric duration; ES, effect size; F@0V, force at zero velocity; FT, flight time; FT:CT, flight time to contraction time ratio; ICC, intraclass correlation coefficient; MF, mean force; MP, mean power; MEccConP, mean eccentric and concentric power over time; MinV, minimum velocity; mRCFD, maximum rate of concentric force development; mREFD, maximum rate of eccentric force development; mRPD, maximum rate of power development; PF, peak force; PP, peak power; PV, peak velocity; RNI, relative net impulse; T2PF, time to peak force; T2PP, time to peak power; TI, total impulse; V@PP, velocity at peak power. Gold standard is a motion capture system for PV, MinV, and JH, and force platform for all remaining variables.
Test–retest reliability of CMJ kinematic variables obtained with two gold-standard pieces of equipment and four portable devices.
| Variable | Reliability Indicators | MCAP | Force Platform | Myotest | Ergojump | Optojump | MyJump |
|---|---|---|---|---|---|---|---|
| CT | ICC (95% CI) | - | 0.84 (0.58; 0.95) | 0.93 (0.83; 0.98) | - | - | - |
| CV (%) | - | 120.1 (7.7; 16.5) | 6.8 (4.9; 8.7) | - | - | - | |
| EccD | ICC (95% CI) | - | 0.81 (0.51; 0.94) | 0.95 (0.87; 0.98) | - | - | - |
| CV (%) | - | 17.5 (10.1; 24.9) | 8.0 (5.7; 10.3) | - | - | - | |
| ConD | ICC (95% CI) | - | 0.89 (0.71; 0.96) | 0.72 (0.27; 0.92) | - | - | - |
| CV (%) | - | 6.8 (5.2; 8.3) | 12.0 (7.1; 16.9) | - | - | - | |
| T2PF | ICC (95% CI) | - | 0.80 (0.48; 0.94) | 0.93 (0.82; 0.98) | - | - | - |
| CV (%) | - | 21.1 (14.4; 27.7) | 7.9 (5.8; 10.1) | - | - | - | |
| T2PP | ICC (95% CI) | - | 0.82 (0.52; 0.95) | 0.93 (0.83; 0.98) | - | - | - |
| CV (%) | - | 13.3 (8.6; 18.1) | 7.0 (5.1; 8.9) | - | - | - | |
| FT | ICC (95% CI) | - | 0.97 (0.92; 0.99) | 0.96 (0.91; 0.99) | 0.54 (−0.34; 0.89) | 0.96 (0.91; 0.99) | 0.80 (0.37; 0.96) |
| CV (%) | - | 1.8 (1.3; 2.2) | 3.8 (0.4; 7.2) | 8.2 (0.8; 15.7) | 1.8 (1.4; 2.3) | 3.0 (2.1; 3.8) | |
| FT:CT | ICC (95% CI) | - | 0.73 (0.30; 0.92) | 0.92 (0.78; 0.98) | - | - | - |
| CV (%) | - | 13.2 (8.0; 18.3) | 8.4 (3.4; 13.4) | - | - | - | |
| PV | ICC (95% CI) | 0.91 (0.78; 0.97) | - | 0.78 (0.44; 0.94) | - | - | 0.74 (0.17; 0.95) |
| CV (%) | 5.2 (3.2; 7.1) | - | 11.6 (7.6; 15.3) | - | - | 3.3 (2.2; 4.4) | |
| MinV | ICC (95% CI) | 0.79 (−39; 0.95) | - | 0.50 (−0.30; 0.86) | - | - | - |
| CV (%) | −6.8 (−8.0; −5.6) | - | −18.0 (−24.6; −12.3) | - | - | - | |
| V@PP | ICC (95% CI) | - | 0.97 (0.92; 0.99) | 0.79 (0.46; 0.94) | - | - | - |
| CV (%) | - | 2.1 (1.54; 2.6) | 11.1 (7.7; 14.5) | - | - | - | |
| JH | ICC (95% CI) | 0.96 (0.90; 0.99) | - | 0.97 (0.92; 0.99) | 0.93 (0.81; 0.98) | 0.87 (0.62; 0.97) | 0.97 (0.91; 0.99) |
| CV (%) | 3.3 (2.2; 4.4) | - | 4.2 (3.2; 5.3) | 3.2 (2.3; 4.1) | 4.2 (3.3; 5.1) | 3.9 (3.0; 4.9) | |
| PF | ICC (95% CI) | - | 0.83 (0.57; 0.95) | 0.91 (0.77; 0.97) | - | - | - |
| CV (%) | - | 3.4 (2.4; 4.5) | 6.4 (4.4; 8.3) | - | - | - | |
| MF | ICC (95% CI) | - | 0.89 (−0.73; 0.96) | 0.89 (0.70; 0.96) | - | - | - |
| CV (%) | - | 5.2 (1.9; 8.5) | 4.2 (2.5; 5.9) | - | - | - | |
| mREFD | ICC (95% CI) | - | 0.89 (0.71; 0.97) | 0.76 (0.37; 0.93) | - | - | - |
| CV (%) | - | 17.1 (10.8; 23.4) | 21.1 (15.3; 26.8) | - | - | - | |
| mRCFD | ICC (95% CI) | - | 0.84 (0.62; 0.95) | 0.28 (−0.29; 0.86) | - | - | - |
| CV (%) | - | 46.4 (30.4; 62.4) | 30.9 (20.9; 40.9) | - | - | - | |
|
| - | - | - | - | - | - | |
| F@0V | ICC (95% CI) | - | 0.90 (0.74; 0.97) | 0.91 (0.77; 0.97) | - | - | - |
| CV (%) | - | 4.3 (2.7; 5.9) | 8.9 (5.6; 12.2) | - | - | - | |
| PP | ICC (95% CI) | - | 0.95 (0.87; 0.98) | 0.81 (0.52; 0.94) | 0.91 (0.79; 0.97) | 0.86 (0.63; 0.96) | 0.84 (0.48; 0.96) |
| CV (%) | - | 3.4 (2.1; 4.7) | 15.8 (11.3; 20.4) | 3.3 (2.3; 4.3) | 4.5 (1.0; 8.1) | 4.0 (3.0; 5.0) | |
| MP | ICC (95% CI) | - | 0.91 (0.77; 0.97) | 0.84 (0.59; 0.95) | - | - | - |
| CV (%) | - | 3.8 (2.7; 5.0) | 14.8 (10.2; 19.3) | - | - | - | |
|
| - | - | - | - | - | - | |
| mRPD | ICC (95% CI) | - | 0.75 (0.34; 0.93) | 0.84 (0.58; 0.95) | - | - | - |
| CV (%) | - | 10.1 (8.0; 12.3) | 16.0 (10.6; 21.3) | - | - | - | |
| MEccCONP | ICC (95% CI) | - | 0.87 (0.65; 0.96) | 0.93 (0.81; 0.98) | - | - | - |
| CV (%) | - | 9.0 (5.9; 12.1) | 9.5 (5.8; 13.2) | - | - | - | |
| TI | ICC (95% CI) | - | 0.79 (0.44; 0.94) | 0.95 (0.87; 0.98) | - | - | - |
| CV (%) | - | 5.6 (1.3; 9.9) | 24.4 (10.8; 37.9) | - | - | - | |
| RNI | ICC (95% CI) | - | 0.97 (0.92; 0.99) | 0.86 (0.63; 0.96) | - | - | - |
| CV (%) | - | 1.7 (1.1; 2.2) | 15.9 (10.1; 21.8) | - | - | - |
MCAP, motion capture system; ConD, concentric duration; CT, total contraction time; EccD, eccentric duration; F@0V, force at zero velocity; FT, flight time; FT:CT, flight time to contraction time ratio; MP, mean power; MEccConP, mean eccentric and concentric power over time; MinV, minimum velocity; mRCFD, maximum rate of concentric force development; mRCED, maximum rate of eccentric force development; mRPD, maximum rate of power development; PF, peak force; PP, peak power; PV, peak velocity; RNI, relative net impulse; T2PF, time to peak force; T2PP, time to peak power; TI, total impulse; V@PP, velocity at peak power. Bold indicates reliable measurements (ICC > 0.75, CV < 10%).
Standard error of measurement, smallest worthwhile change, and minimum detectable change of jump variables obtained with different devices.
| Variable | MCAP | Force Platform | Myotest | Ergojump | Optojump | MyJump | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SEM | SWC | MDC | SEM | SWC | MDC | SEM | SWC | MDC | SEM | SWC | MDC | SEM | SWC | MDC | SEM | SWC | MDC | |
|
| ||||||||||||||||||
| CT (s) | - | - | - | 0.02 | 0.03 | 0.05 | 0.012 | 0.018 | 0.033 | - | - | - | - | - | - | - | - | - |
| EccD (s) | - | - | - | 0.01 | 0.03 | 0.05 | 0.010 | 0.016 | 0.029 | - | - | - | - | - | - | - | - | - |
| ConD (s) | - | - | - | 0.003 | 0.006 | 0.01 | 0.005 | 0.008 | 0.015 | - | - | - | - | - | - | - | - | - |
| T2PF (s) | - | - | - | 0.02 | 0.03 | 0.06 | 0.013 | 0.021 | 0.038 | - | - | - | - | - | - | - | - | - |
| T2PP (s) | - | - | - | 0.02 | 0.03 | 0.06 | 0.011 | 0.018 | 0.033 | - | - | - | - | - | - | - | - | - |
| FT (s) | - | - | - | 0.004 | 0.006 | 0.01 | 0.005 | 0.008 | 0.015 | 0.008 | 0.013 | 0.024 | 0.004 | 0.006 | 0.012 | 0.003 | 0.006 | 0.010 |
| FT:CT (%) | - | - | - | 0.02 | 0.03 | 0.05 | 0.013 | 0.021 | 0.038 | - | - | - | - | - | - | - | - | |
| PV (m∙s−1) | 0.04 | 0.06 | 0.11 | - | - | - | 0.050 | 0.078 | 0.14 | - | - | - | - | - | - | - | - | |
| MinV (m∙s−1) | 0.02 | 0.03 | 0.05 | - | - | - | 0.032 | 0.050 | 0.090 | - | - | - | - | - | - | - | - | |
| V@PP (m∙s−1) | - | - | - | 0.02 | 0.03 | 0.05 | 0.04 | 0.06 | 0.056 | - | - | - | - | - | 0.009 | 0.015 | 0.027 | |
| JH (m) | 0.005 | 0.008 | 0.015 | - | - | - | 0.005 | 0.008 | 0.014 | 0.010 | 0.015 | 0.028 | 0.005 | 0.009 | 0.016 | 0.005 | 0.008 | 0.015 |
|
| ||||||||||||||||||
| PF (N∙kg−1) | - | - | - | 0.26 | 0.40 | 0.73 | 0.30 | 0.47 | 0.84 | - | - | - | - | - | - | - | - | - |
| MF (N∙kg−1) | - | - | - | 0.16 | 0.26 | 0.47 | 0.10 | 0.16 | 0.47 | - | - | - | - | - | - | - | - | - |
| mREFD (N∙s−1∙kg−1) | - | - | - | 9.42 | 1.88 | 26.11 | 4.88 | 0.97 | 13.53 | - | - | - | - | - | - | - | - | - |
| mRCFD (N∙s−1∙kg−1) | - | - | - | 2.74 | 0.54 | 7.59 | 3.46 | 0.69 | 9.61 | - | - | - | - | - | - | - | - | - |
| F@0V (N∙kg−1) | - | - | - | 0.30 | 0.47 | 0.84 | 0.42 | 0.65 | 1.17 | - | - | - | - | - | - | - | - | - |
| PP (W∙kg−1) | - | - | - | 0.63 | 0.98 | 1.76 | 1.13 | 1.76 | 3.15 | 1.31 | 2.03 | 3.63 | 0.69 | 1.07 | 1.92 | 0.49 | 0.76 | 1.36 |
| MP (W∙kg−1) | - | - | - | 0.32 | 0.51 | 0.91 | 0.67 | 1.03 | 1.86 | - | - | - | - | - | - | - | - | - |
| mRPD (W∙s−1) | - | - | - | 11.38 | 2.27 | 31.54 | 0.30 | 0.06 | 0.84 | - | - | - | - | - | - | - | - | - |
| MEccConP (W∙kg−1∙s−1) | - | - | - | 0.29 | 0.45 | 0.80 | 0.25 | 0.40 | 0.71 | - | - | - | - | - | - | - | - | - |
| TI (N∙s−1) | - | - | - | 4.06 | 6.29 | 11.26 | 6.24 | 9.67 | 17.30 | - | - | - | - | - | - | - | - | - |
| RNI (N∙s−1∙kg−1) | - | - | - | 0.02 | 0.03 | 0.05 | 0.05 | 0.08 | 0.14 | - | - | - | - | - | - | - | - | - |
MCAP, motion capture system; ConD, concentric duration; CT, total contraction time; EccD, eccentric duration; F@0V, force at zero velocity; FT, flight time; FT:CT, flight time to contraction time ratio; MCD, minimal detectable change; MF, mean force; MP, mean power; MEccConP, mean eccentric and concentric power over time; MEF, mean eccentric force; MinV, minimum velocity; mRCFD, maximum rate of concentric force development; mRCED, maximum rate of eccentric force development; mRPD, maximum rate of power development; PF, peak force; PP, peak power; PV, peak velocity; RNI, relative net impulse; SEM, standard error of measurement; SWC, smallest worthwhile change; T2PF, time to peak force; T2PP, time to peak power; TI, total impulse; V@PP, velocity at peak power.