Literature DB >> 15702453

Performance characteristics of gas analysis systems: what we know and what we need to know.

G Atkinson1, R C R Davison, A M Nevill.   

Abstract

It is important that sources of variation in gas analysis measurements are identified and described in an accurate and informative manner. In this paper, we discussed the potential sources of error, which should be considered in any measurement study on gas analysis systems. We then covered how errors in various terms associated with gas laws propagate to outcome measurements of gas exchange to help quantify the relative importance of sources of error. Finally, we performed a literature survey to explore the statistical methods researchers have employed to arrive at conclusions on the performance characteristics of gas analysis methods. We found examples of excellent practice in the literature, but there were also gaps in the knowledge of error in gas analysis systems. Consequently, we supplied guidelines for future method comparison studies. These guidelines included (i) a sample size of at least 40 participants and the citation of confidence intervals, (ii) a description of the relationships between systematic and random errors and the size of measured value, (iii) the parallel examination of test-retest error within a method comparison study, and (iv) an a priori-made judgement on how much systematic and random error between methods is acceptable for practical applications. We stressed that this judgement should be based on expert-agreed position statements about acceptable error, which unfortunately have yet to be formulated for gas analysis systems.

Entities:  

Mesh:

Year:  2005        PMID: 15702453     DOI: 10.1055/s-2004-830505

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  19 in total

Review 1.  Measurement of human energy expenditure, with particular reference to field studies: an historical perspective.

Authors:  Roy J Shephard; Yukitoshi Aoyagi
Journal:  Eur J Appl Physiol       Date:  2011-12-11       Impact factor: 3.078

Review 2.  Future perspectives in the evaluation of the physiological demands of soccer.

Authors:  Barry Drust; Greg Atkinson; Thomas Reilly
Journal:  Sports Med       Date:  2007       Impact factor: 11.136

3.  Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method.

Authors:  Hans Rosdahl; Lennart Gullstrand; Jane Salier-Eriksson; Patrik Johansson; Peter Schantz
Journal:  Eur J Appl Physiol       Date:  2009-12-31       Impact factor: 3.078

4.  Validity of the Oxycon Mobile metabolic system under field measuring conditions.

Authors:  Jane Salier Eriksson; Hans Rosdahl; Peter Schantz
Journal:  Eur J Appl Physiol       Date:  2011-05-11       Impact factor: 3.078

5.  Reliability and validity assessment of a linear position transducer.

Authors:  Manuel V Garnacho-Castaño; Silvia López-Lastra; José L Maté-Muñoz
Journal:  J Sports Sci Med       Date:  2015-03-01       Impact factor: 2.988

6.  Reliability and Validity of the Polar V800 Sports Watch for Estimating Vertical Jump Height.

Authors:  Manuel V Garnacho-Castaño; Marcos Faundez-Zanuy; Noemí Serra-Payá; José L Maté-Muñoz; Josep López-Xarbau; Moisés Vila-Blanch
Journal:  J Sports Sci Med       Date:  2021-03-01       Impact factor: 2.988

7.  The Moxus Modular metabolic system evaluated with two sensors for ventilation against the Douglas bag method.

Authors:  Hans Rosdahl; Thomas Lindberg; Fredrik Edin; Johnny Nilsson
Journal:  Eur J Appl Physiol       Date:  2012-12-07       Impact factor: 3.078

8.  Accelerometer output and MET values of common physical activities.

Authors:  Sarah L Kozey; Kate Lyden; Cheryl A Howe; John W Staudenmayer; Patty S Freedson
Journal:  Med Sci Sports Exerc       Date:  2010-09       Impact factor: 5.411

Review 9.  Open-circuit respirometry: a historical review of portable gas analysis systems.

Authors:  Duncan J Macfarlane
Journal:  Eur J Appl Physiol       Date:  2017-10-17       Impact factor: 3.078

Review 10.  Open-circuit respirometry: real-time, laboratory-based systems.

Authors:  Susan A Ward
Journal:  Eur J Appl Physiol       Date:  2018-05-04       Impact factor: 3.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.