Literature DB >> 22648140

Concurrent validity of vertical jump performance assessment systems.

Carlo Castagna1, Marco Ganzetti, Massimiliano Ditroilo, Marco Giovannelli, Alessandro Rocchetti, Vincenzo Manzi.   

Abstract

The aim of this study was to examine the concurrent validity of 2 portable systems for vertical jump (VJ) assessment under field conditions. The VJ flight times assessed using an optical mat (Optojump) and an accelerometer-based (Myotest) system were compared with that of a force platform. The flight times recorded during a countermovement jump (CMJ) were collected from 20 rugby players (n = 86 jumps) concurrently using the 3 tracking systems. Significant bias between the Force platform and either the Optojump (bias = 0.006 ± 0.007; 95% confidence interval [CI] 0.004-0.007 seconds) and Myotest (bias = -0.031 ± 0.021; 95% CI 0.035 to -0.026s; p < 0.0001) occurred. A nearly perfect correlation was found between force platform and Optojump (r = 0.99; 95% CI 0.098-0.99; p < 0.0001). Force platform and Myotest (r = 0.89; 95% CI 0.084-0.93; p < 0.0001) flight times showed very large association. Difference between Optojump and Myotest systems was significant (-0.036 ± 0.021 seconds; 95% CI -0.041 to -0.032; p < 0.0001), which results in Myotest mean flight time being approximately 7.2% longer than the Optojump flight time. The association between Optojump and Myotest was nearly perfect (r = 0.91, 95% CI 0.86-0.94; p < 0.0001). This study showed that the Optojump and Myotest systems possess convergent validity and can be successfully used under field conditions to assess VJ while performing a CMJ. However, caution should be exercised when interpreting data obtained from different portable systems for field measurement.

Mesh:

Year:  2013        PMID: 22648140     DOI: 10.1519/JSC.0b013e31825dbcc5

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  28 in total

Review 1.  Physical and physiological profiles of taekwondo athletes.

Authors:  Craig A Bridge; Jonatas Ferreira da Silva Santos; Helmi Chaabène; Willy Pieter; Emerson Franchini
Journal:  Sports Med       Date:  2014-06       Impact factor: 11.136

Review 2.  Trends Supporting the In-Field Use of Wearable Inertial Sensors for Sport Performance Evaluation: A Systematic Review.

Authors:  Valentina Camomilla; Elena Bergamini; Silvia Fantozzi; Giuseppe Vannozzi
Journal:  Sensors (Basel)       Date:  2018-03-15       Impact factor: 3.576

3.  Wearables for Running Gait Analysis: A Systematic Review.

Authors:  Rachel Mason; Liam T Pearson; Gillian Barry; Fraser Young; Oisin Lennon; Alan Godfrey; Samuel Stuart
Journal:  Sports Med       Date:  2022-10-15       Impact factor: 11.928

4.  Arthroscopic correction of femoroacetabular impingement improves athletic performance in male athletes.

Authors:  Karen Mullins; Michael Hanlon; Patrick Carton
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-08-28       Impact factor: 4.342

5.  THE EFFECTS OF WHOLE BODY VIBRATION ON VERTICAL JUMP, POWER, BALANCE, AND AGILITY IN UNTRAINED ADULTS.

Authors:  Harvey W Wallmann; David L Bell; Brandon L Evans; Adam A Hyman; Gary K Goss; Adam M Paicely
Journal:  Int J Sports Phys Ther       Date:  2019-02

Review 6.  MEMS sensor technologies for human centred applications in healthcare, physical activities, safety and environmental sensing: a review on research activities in Italy.

Authors:  Gastone Ciuti; Leonardo Ricotti; Arianna Menciassi; Paolo Dario
Journal:  Sensors (Basel)       Date:  2015-03-17       Impact factor: 3.576

7.  Concurrent Validity and Test-retest Reliability of the OPTOGait Photoelectric Cell System for the Assessment of Spatio-temporal Parameters of the Gait of Young Adults.

Authors:  Myung Mo Lee; Chang Ho Song; Kyoung Jin Lee; Sang Woo Jung; Doo Chul Shin; Seung Ho Shin
Journal:  J Phys Ther Sci       Date:  2014-02-06

8.  Assessing Reactive Strength Measures in Jumping and Hopping Using the Optojump™ System.

Authors:  Robin Healy; Ian C Kenny; Andrew J Harrison
Journal:  J Hum Kinet       Date:  2016-12-15       Impact factor: 2.193

9.  Concurrent validity of the Gyko inertial sensor system for the assessment of vertical jump height in female sub-elite youth soccer players.

Authors:  Melanie Lesinski; Thomas Muehlbauer; Urs Granacher
Journal:  BMC Sports Sci Med Rehabil       Date:  2016-11-11

10.  Mobile Jump Assessment (mJump): A Descriptive and Inferential Study.

Authors:  Alvaro Mateos-Angulo; Alejandro Galán-Mercant; Antonio Cuesta-Vargas
Journal:  JMIR Rehabil Assist Technol       Date:  2015-08-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.