Literature DB >> 30190653

Establishment of national diagnostic reference levels (DRLs) for radiotherapy localisation computer tomography of the head and neck.

Celine Clerkin1, Sinead Brennan2, Laura M Mullaney1.   

Abstract

AIM: The aim of this research is to establish if variation exists in the dose delivered for head and neck (HN) localisation computed tomography (CT) imaging in radiation therapy (RT); to propose a national diagnostic reference levels (DRLs) for this procedure and to make a comparison between the national DRL and a DRL of a European sample.
BACKGROUND: CT has become an indispensable tool in radiotherapy (RT) treatment planning. It is a requirement of legislation in many countries that doses of ionising radiation for medical exposures be kept 'As Low As Reasonably Achievable'. There are currently no dose guidelines for RT localisation CT of the HN.
MATERIALS AND METHODS: All RT departments in Ireland and a sample of European departments were surveyed. Dose data on CT dose length product (DLP); dose index volume (CTDIvol); current time product; tube voltage and scan length was acquired for ten average-sized HN patients from each department. DRLs were proposed for DLP and CTDIvol using the rounded 75th percentile of the distribution of the means.
RESULTS: 42% of Irish departments and one European department completed the survey. Significant variation was found in the mean DLP, CTDIvol and scan lengths across the Irish departments. The proposed Irish DRL is 882 mGy cm and 21 mGy and the European department DRL is 816 mGy cm and 21 mGy, for DLP and CTDIvol, respectively.
CONCLUSIONS: Variation exists in doses used for HN RT localisation CT. DRLs have been proposed for comparison purposes with the aim of dose optimisation.

Entities:  

Keywords:  CT localisation; Diagnostic reference levels; Head and neck; Radiotherapy

Year:  2018        PMID: 30190653      PMCID: PMC6107902          DOI: 10.1016/j.rpor.2018.07.012

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  20 in total

1.  Managing patient dose in computed tomography. A report of the International Commission on Radiological Protection.

Authors: 
Journal:  Ann ICRP       Date:  2000

2.  Adult reference levels in diagnostic and interventional radiology for temporary use in Switzerland.

Authors:  A Aroua; A Besançon; I Buchillier-Decka; P Trueb; J-F Valley; F R Verdun; W Zeller
Journal:  Radiat Prot Dosimetry       Date:  2004-07-20       Impact factor: 0.972

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

4.  Doses to critical organs following radiotherapy and concomitant imaging of the larynx and breast.

Authors:  R M Harrison; M Wilkinson; D J Rawlings; M Moore
Journal:  Br J Radiol       Date:  2007-12       Impact factor: 3.039

5.  Establishment of CT diagnostic reference levels in Ireland.

Authors:  S J Foley; M F McEntee; L A Rainford
Journal:  Br J Radiol       Date:  2012-05-17       Impact factor: 3.039

6.  CT dose index and patient dose: they are not the same thing.

Authors:  Cynthia H McCollough; Shuai Leng; Lifeng Yu; Dianna D Cody; John M Boone; Michael F McNitt-Gray
Journal:  Radiology       Date:  2011-05       Impact factor: 11.105

7.  Radiation Doses in Consecutive CT Examinations from Five University of California Medical Centers.

Authors:  Rebecca Smith-Bindman; Michelle Moghadassi; Nicole Wilson; Thomas R Nelson; John M Boone; Christopher H Cagnon; Robert Gould; David J Hall; Mayil Krishnam; Ramit Lamba; Michael McNitt-Gray; Anthony Seibert; Diana L Miglioretti
Journal:  Radiology       Date:  2015-05-19       Impact factor: 11.105

8.  Fourth review of the UK national patient dose database.

Authors:  D Hart; P C Shrimpton
Journal:  Br J Radiol       Date:  2012-10       Impact factor: 3.039

9.  The 15-Country Collaborative Study of Cancer Risk among Radiation Workers in the Nuclear Industry: estimates of radiation-related cancer risks.

Authors:  E Cardis; M Vrijheid; M Blettner; E Gilbert; M Hakama; C Hill; G Howe; J Kaldor; C R Muirhead; M Schubauer-Berigan; T Yoshimura; F Bermann; G Cowper; J Fix; C Hacker; B Heinmiller; M Marshall; I Thierry-Chef; D Utterback; Y-O Ahn; E Amoros; P Ashmore; A Auvinen; J-M Bae; J Bernar; A Biau; E Combalot; P Deboodt; A Diez Sacristan; M Eklöf; H Engels; G Engholm; G Gulis; R R Habib; K Holan; H Hyvonen; A Kerekes; J Kurtinaitis; H Malker; M Martuzzi; A Mastauskas; A Monnet; M Moser; M S Pearce; D B Richardson; F Rodriguez-Artalejo; A Rogel; H Tardy; M Telle-Lamberton; I Turai; M Usel; K Veress
Journal:  Radiat Res       Date:  2007-04       Impact factor: 2.841

10.  Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults.

Authors:  Aaron Sodickson; Pieter F Baeyens; Katherine P Andriole; Luciano M Prevedello; Richard D Nawfel; Richard Hanson; Ramin Khorasani
Journal:  Radiology       Date:  2009-04       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.