BACKGROUND: The Micra transcatheter pacing system (TPS) is a miniaturized, single-chamber pacemaker system. Study reported herein is an initial experience with implantation of the Micra TPS. METHODS: The leadless pacemaker was implanted in 10 patients with standard indications for a permanent pacemaker implantation. All hospitalization costs were calculated for all patients. RESULTS: The mean age of the patients was 75 ± 7.1 years, 6 were men and 4 were women. Four patients had permanent atrial fibrillation as the basal rhythm and 6 patients had sinus rhythm. All patients had at least one relative contraindication that precluded the use of a traditional pacing system. Mean intraoperative ventricular sensing amplitude was 10.6 ± 5.4 mV, impedance 843 ± 185 ohms, and pacing threshold at 0.24 ms was 0.56 ± 0.23 V. At discharge, those values were 13.9 ± 5.6 mV, 667 ± 119 ohms and 0.47 ± 0.17, respectively. The mean duration of implantation procedure was 82 min, while mean fluoroscopy time was 3.5 min. Two patients developed hematoma at the groin puncture site post-implantation. In 1 case there was a need for erythrocyte mass transfusion and surgical intervention. Mean total time of hospitalization was 26 days and time from procedure to discharge 12 days. Average cost of hospitalization per 1 patient was 11,260.15 EUR minimal cost was 9,052.68 EUR, while maximal cost was 16,533.18 EUR. CONCLUSIONS: Implantation of leadless pacemakers is feasible, safe and provides advantages over the conventional system. Hospitalization costs vary for individual patients in wide range.
BACKGROUND: The Micra transcatheter pacing system (TPS) is a miniaturized, single-chamber pacemaker system. Study reported herein is an initial experience with implantation of the Micra TPS. METHODS: The leadless pacemaker was implanted in 10 patients with standard indications for a permanent pacemaker implantation. All hospitalization costs were calculated for all patients. RESULTS: The mean age of the patients was 75 ± 7.1 years, 6 were men and 4 were women. Four patients had permanent atrial fibrillation as the basal rhythm and 6 patients had sinus rhythm. All patients had at least one relative contraindication that precluded the use of a traditional pacing system. Mean intraoperative ventricular sensing amplitude was 10.6 ± 5.4 mV, impedance 843 ± 185 ohms, and pacing threshold at 0.24 ms was 0.56 ± 0.23 V. At discharge, those values were 13.9 ± 5.6 mV, 667 ± 119 ohms and 0.47 ± 0.17, respectively. The mean duration of implantation procedure was 82 min, while mean fluoroscopy time was 3.5 min. Two patients developed hematoma at the groin puncture site post-implantation. In 1 case there was a need for erythrocyte mass transfusion and surgical intervention. Mean total time of hospitalization was 26 days and time from procedure to discharge 12 days. Average cost of hospitalization per 1 patient was 11,260.15 EUR minimal cost was 9,052.68 EUR, while maximal cost was 16,533.18 EUR. CONCLUSIONS: Implantation of leadless pacemakers is feasible, safe and provides advantages over the conventional system. Hospitalization costs vary for individual patients in wide range.
Authors: Dwight Reynolds; Gabor Z Duray; Razali Omar; Kyoko Soejima; Petr Neuzil; Shu Zhang; Calambur Narasimhan; Clemens Steinwender; Josep Brugada; Michael Lloyd; Paul R Roberts; Venkata Sagi; John Hummel; Maria Grazia Bongiorni; Reinoud E Knops; Christopher R Ellis; Charles C Gornick; Matthew A Bernabei; Verla Laager; Kurt Stromberg; Eric R Williams; J Harrison Hudnall; Philippe Ritter Journal: N Engl J Med Date: 2015-11-09 Impact factor: 91.245
Authors: Vivek Y Reddy; Derek V Exner; Daniel J Cantillon; Rahul Doshi; T Jared Bunch; Gery F Tomassoni; Paul A Friedman; N A Mark Estes; John Ip; Imran Niazi; Kenneth Plunkitt; Rajesh Banker; James Porterfield; James E Ip; Srinivas R Dukkipati Journal: N Engl J Med Date: 2015-08-30 Impact factor: 91.245
Authors: Reinoud E Knops; Fleur V Y Tjong; Petr Neuzil; Johannes Sperzel; Marc A Miller; Jan Petru; Jaroslav Simon; Lucie Sediva; Joris R de Groot; Srinivas R Dukkipati; Jacob S Koruth; Arthur A M Wilde; Josef Kautzner; Vivek Y Reddy Journal: J Am Coll Cardiol Date: 2015-04-21 Impact factor: 24.094
Authors: Paul R Roberts; Nicolas Clementy; Faisal Al Samadi; Christophe Garweg; Jose Luis Martinez-Sande; Saverio Iacopino; Jens Brock Johansen; Xavier Vinolas Prat; Robert C Kowal; Didier Klug; Lluis Mont; Jan Steffel; Shelby Li; Dirk Van Osch; Mikhael F El-Chami Journal: Heart Rhythm Date: 2017-05-11 Impact factor: 6.343
Authors: Mikhael F El-Chami; Paul R Roberts; Alex Kypta; Pamela Omdahl; Matthew D Bonner; Robert C Kowal; Gabor Z Duray Journal: J Cardiovasc Electrophysiol Date: 2016-10-03
Authors: Erik O Udo; Nicolaas P A Zuithoff; Norbert M van Hemel; Carel C de Cock; Thijs Hendriks; Pieter A Doevendans; Karel G M Moons Journal: Heart Rhythm Date: 2011-12-17 Impact factor: 6.343
Authors: Muhammad R Sohail; Daniel Z Uslan; Akbar H Khan; Paul A Friedman; David L Hayes; Walter R Wilson; James M Steckelberg; Sarah Stoner; Larry M Baddour Journal: J Am Coll Cardiol Date: 2007-04-23 Impact factor: 24.094
Authors: Alexander Kypta; Hermann Blessberger; Juergen Kammler; Thomas Lambert; Michael Lichtenauer; Walter Brandstaetter; Michael Gabriel; Clemens Steinwender Journal: J Cardiovasc Electrophysiol Date: 2016-07-27
Authors: Larry M Baddour; Andrew E Epstein; Christopher C Erickson; Bradley P Knight; Matthew E Levison; Peter B Lockhart; Frederick A Masoudi; Eric J Okum; Walter R Wilson; Lee B Beerman; Ann F Bolger; N A Mark Estes; Michael Gewitz; Jane W Newburger; Eleanor B Schron; Kathryn A Taubert Journal: Circulation Date: 2010-01-04 Impact factor: 29.690
Authors: Philippe Ritter; Gabor Z Duray; Clemens Steinwender; Kyoko Soejima; Razali Omar; Lluís Mont; Lucas V A Boersma; Reinoud E Knops; Larry Chinitz; Shu Zhang; Calambur Narasimhan; John Hummel; Michael Lloyd; Timothy Alexander Simmers; Andrew Voigt; Verla Laager; Kurt Stromberg; Matthew D Bonner; Todd J Sheldon; Dwight Reynolds Journal: Eur Heart J Date: 2015-06-04 Impact factor: 29.983