How to Implant a Leadless Pacemaker With a Tine-Based Fixation.

Mikhael F El-Chami1, Paul R Roberts2, Alex Kypta3, Pamela Omdahl4, Matthew D Bonner4, Robert C Kowal5, Gabor Z Duray6.   

Abstract

Two major studies have shown that leadless pacemakers are safe and effective for patients requiring right ventricular rate responsive pacing therapy. This positive result recently led to FDA approval of one of the available leadless pacing devices. While this new technology is promising, it requires a different skill set for safe implantation. In this article, we review in detail the different steps required for implantation of tine-based leadless pacemakers while providing tips and tricks to minimize complications.
© 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  Micra; Nanostim; leadless pacemaker; transvenous pacemaker

Mesh:

Year:  2016        PMID: 27600684     DOI: 10.1111/jce.13092

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  11 in total

1.  Implantation of the Micra transcatheter pacing system: Single Polish center experience with the real costs of hospitalization analysis.

Authors:  Marcin Grabowski; Marcin Michalak; Monika Gawałko; Sylwia Gajda; Andrzej Cacko; Łukasz Januszkiewicz; Agnieszka Kołodzińska; Przmysław P Mitkowski; Gabor Z Duray; Grzegorz Opolski
Journal:  Cardiol J       Date:  2018-08-29       Impact factor: 2.737

2.  Leadless pacemaker implantation: A feasible and reasonable option in transcatheter heart valve replacement patients.

Authors:  Sarah K L Moore; Katherine H Chau; Salma Chaudhary; Geoffrey Rubin; Joseph Bayne; Uma Mahesh R Avula; Daniel Y Wang; Carmine Sorbera; Jose Dizon; Angelo Biviano; Marc Waase; Vivek Iyer; Isaac George; Susheel K Kodali; Tamim M Nazif; Hasan Garan; Elaine Y Wan
Journal:  Pacing Clin Electrophysiol       Date:  2019-03-18       Impact factor: 1.976

3.  Successful implantation of a Micra leadless pacemaker via collateral femoral vein and inferior vena cava filter.

Authors:  Erica Flores; Mayur Patel; Geoffery Orme; Wilber Su
Journal:  Clin Case Rep       Date:  2018-01-30

4.  Leadless pacemaker implantation after transcatheter lead extraction in complex anatomy patient.

Authors:  Valentina De Regibus; Antonino Pardeo; Paolo Artale; Andrea Petretta; Pasquale Filannino; Saverio Iacopino
Journal:  Clin Case Rep       Date:  2018-04-19

5.  Visualization and appearance of artifacts of leadless pacemaker systems in cardiac MRI : An experimental ex vivo study.

Authors:  Christoph Edlinger; Marcel Granitz; Vera Paar; Christian Jung; Alexander Pfeil; Sarah Eder; Bernhard Wernly; Jürgen Kammler; Klaus Hergan; Uta C Hoppe; Clemens Steinwender; Michael Lichtenauer; Alexander Kypta
Journal:  Wien Klin Wochenschr       Date:  2018-05-23       Impact factor: 1.704

6.  The use of a single chamber leadless pacemaker for the treatment of cardioinhibitory vasovagal syncope.

Authors:  Paul R Roberts; Christopher Pepper; Christopher A Rinaldi; Matthew G D Bates; Andrew Thornley; Riyaz Somani; Khalid Abozguia; Stuart Harris; Archana Rao; Michala Pedersen; Janet M McComb; Ewen Shepherd; Philip Moore; Oliver R Segal; Richard J Schilling; Amir Zaidi
Journal:  Int J Cardiol Heart Vasc       Date:  2019-03-28

7.  Optimizing mechanically sensed atrial tracking in patients with atrioventricular-synchronous leadless pacemakers: A single-center experience.

Authors:  Kelly Arps; Jonathan P Piccini; Rebecca Yapejian; Rhonda Leguire; Brenda Smith; Sana M Al-Khatib; Tristram D Bahnson; James P Daubert; Donald D Hegland; Kevin P Jackson; Larry R Jackson; Robert K Lewis; Sean D Pokorney; Albert Y Sun; Kevin L Thomas; Camille Frazier-Mills
Journal:  Heart Rhythm O2       Date:  2021-08-23

8.  Novel atrioventricular sequential pacing approach using a transvenous atrial pacemaker and a leadless pacemaker: a case report.

Authors:  Elhosseyn Guella; Frances Devereux; Fozia Zahir Ahmed; Peter Scott; Colin Cunnington; Amir Zaidi
Journal:  Eur Heart J Case Rep       Date:  2021-07-19

9.  Fluoroscopic predictors of acceptable capture threshold during the implantation of the micra transcatheter pacing system.

Authors:  Ikuko Togashi; Toshiaki Sato; Akiko Maeda; Takato Mohri; Yumi Katsume; Mika Tashiro; Yuichi Momose; Noriko Nonoguchi; Kyoko Hoshida; Yosuke Miwa; Akiko Ueda; Kyoko Soejima
Journal:  J Cardiovasc Electrophysiol       Date:  2022-03-25       Impact factor: 2.942

10.  Outcomes using a single tapered dilator for Micra leadless pacemaker implant.

Authors:  Moghniuddin Mohammed; Juwairiya Arshi; Brian M Ramza; Alan P Wimmer; Daniel A Steinhaus; Michael J Giocondo; Sanjaya K Gupta; Omair K Yousuf
Journal:  Indian Pacing Electrophysiol J       Date:  2020-03-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.