Literature DB >> 30082333

Safety and efficacy of the Derivo Embolization Device for the treatment of ruptured intracranial aneurysms.

Lukas Goertz1, Franziska Dorn2, Bastian Kraus3, Jan Borggrefe4, Marc Schlamann4, Robert Forbrig2, Bernd Turowski3, Christoph Kabbasch4.   

Abstract

BACKGROUND: The Derivo Embolization Device (DED) is a novel flow diverter with advanced X-ray visibility, potentially lower thrombogenicity, and an improved delivery system.
OBJECTIVE: To evaluate the safety and efficacy of the DED for emergency treatment of ruptured intracranial aneurysms.
METHODS: Between February 2016 and March 2018, 10 patients (median age 54.5 years, seven women) with 11 aneurysms were treated with the DED at three neurovascular centers. Procedural details, complications, morbidity, and aneurysm occlusion (O'Kelly-Marotta scale, OKM) were retrospectively reviewed.
RESULTS: Among 11 aneurysms treated, there were nine anterior circulation and two posterior circulation aneurysms. Aneurysm morphology was saccular in four cases, dissecting in three, blister-like in three, and fusiform in one. In each case, a single DED was implanted and deployment was technically successful without exception. Adjunctive coiling was performed in two aneurysms. We observed one in-stent thrombosis, presumably due to low response to clopidogrel 4 days after the procedure, which remained with a mild hemiparesis after aspiration thrombectomy. No further thromboembolic or hemorrhagic events occurred. Favorable outcome (modified Rankin scale score ≤2) at last follow-up was achieved in all patients. Among 10 aneurysms available for angiographic follow-up, complete aneurysm occlusion (OKM D) was obtained in nine cases (90.0%).
CONCLUSIONS: In this pilot study, endovascular treatment of ruptured intracranial aneurysms with the DED was feasible and not associated with any incidence of rebleeding. Larger series with longer follow-up are warranted to reach a definite conclusion about this device. © Author(s) (or their employer(s)) 2019. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  aneurysm; angiography; device; flow diverter; intervention

Mesh:

Year:  2018        PMID: 30082333     DOI: 10.1136/neurintsurg-2018-014166

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  9 in total

1.  Implantation of Large Diameter (5.5-6 mm) Derivo Embolization Devices for the Treatment of Cerebral Aneurysms.

Authors:  Waleed Butt; Cha-Ney Kim; Rajesh Ramaswamy; Aubrey Smith; Paul Maliakal
Journal:  Clin Neuroradiol       Date:  2021-09-08       Impact factor: 3.649

2.  Small Unruptured Intracranial Aneurysms Can Be Effectively Treated With Flow-Diverting Devices.

Authors:  Li Li; Bu-Lang Gao; Qiu-Ji Shao; Guang-Lin Zhang; Zi-Liang Wang; Tian-Xiao Li; Liang-Fu Zhu
Journal:  Front Neurol       Date:  2022-05-30       Impact factor: 4.086

3.  Thrombogenicity assessment of Pipeline, Pipeline Shield, Derivo and P64 flow diverters in an in vitro pulsatile flow human blood loop model.

Authors:  Gaurav Girdhar; Samantha Ubl; Reza Jahanbekam; Sinduja Thinamany; Anna Belu; John Wainwright; Michael F Wolf
Journal:  eNeurologicalSci       Date:  2019-01-08

4.  Ruptured Basilar Artery Dissection Diagnosed Using Magnetic Resonance Vessel Wall Imaging and Treated with Coil Embolization with Overlapping LVIS Stents: A Case Report.

Authors:  Shinya Sonobe; Masahiro Yoshida; Kuniyasu Niizuma; Teiji Tominaga
Journal:  NMC Case Rep J       Date:  2020-03-24

5.  Comaneci-Assisted Coiling as a Treatment Option for Acutely Ruptured Wide Neck Cerebral Aneurysm: Case Series of 118 Patients.

Authors:  Alexander Sirakov; Krasimir Minkin; Marin Penkov; Kristian Ninov; Vasil Karakostov; Stanimir Sirakov
Journal:  Neurosurgery       Date:  2020-11-16       Impact factor: 4.654

6.  Propensity score-adjusted analysis on stent-assisted coiling versus coiling alone for ruptured intracranial aneurysms.

Authors:  Lukas Goertz; Thomas Liebig; Lenhard Pennig; Marco Timmer; Hanna Styczen; Jan-Peter Grunz; Thorsten Lichtenstein; Marc Schlamann; Christoph Kabbasch
Journal:  Sci Rep       Date:  2021-11-05       Impact factor: 4.379

7.  Outcome of Flow Diverters with Surface Modifications in Treatment of Cerebral Aneurysms: Systematic Review and Meta-analysis.

Authors:  Y-L Li; A Roalfe; E Y-L Chu; R Lee; A C O Tsang
Journal:  AJNR Am J Neuroradiol       Date:  2020-12-31       Impact factor: 3.825

8.  The Silk Vista Baby - The UK experience.

Authors:  P Bhogal; Hld Makalanda; K Wong; P Keston; J Downer; J C Du Plessis; A Nania; D Simonato; M Fuschi; W Chong; S O'Reilly; I Rennie
Journal:  Interv Neuroradiol       Date:  2021-06-02       Impact factor: 1.764

Review 9.  Outcomes after Flow Diverter Treatment in Subarachnoid Hemorrhage: A Meta-Analysis and Development of a Clinical Prediction Model (OUTFLOW).

Authors:  Michelle F M Ten Brinck; Viktoria E Shimanskaya; René Aquarius; Ronald H M A Bartels; Frederick J A Meijer; Petra C Koopmans; Guido de Jong; Ajay K Wakhloo; Joost de Vries; Hieronymus D Boogaarts
Journal:  Brain Sci       Date:  2022-03-15
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.