Improved accuracy of computer-assisted cervical pedicle screw insertion.

Yoshihisa Kotani1, Kuniyoshi Abumi, Manabu Ito, Akio Minami.   

Abstract

OBJECT: The authors introduce a unique computer-assisted cervical pedicle screw (CPS) insertion technique used in conjunction with specially modified original pedicle screw insertion instruments. The accuracy of screw placement as well as surgery-related outcome and complication rates were compared between two groups of patients: those in whom a computer-assisted and those in whom a conventional manual insertion technique was used.
METHODS: The screw insertion guiding system consisted of a modified awl, probe, tap and a screwdriver specially designed for a computer-assisted CPS insertion. Using this system, real-time instrument/screw tip information was three dimensionally identified in each step of screw insertion. Seventeen patients underwent CPS fixation in which a computer-assisted surgical navigation system was used. The cervical disorders consisted of spondylotic myelopathy with segmental instability or kyphosis, metastatic spinal tumor, rheumatoid spine, and postlaminectomy kyphosis. The rate of pedicle wall perforation was significantly lower in the computer-assisted group than that in the other group (1.2 and 6.7%, respectively; p < 0.05). The screw trajectory in the horizontal plane was significantly closer to the anatomical pedicle axis in the computer-assisted group compared with the manual insertion group (p < 0.05). This factor significantly reduced the incidence of screw perforation laterally. Complications such as neural damage or vascular injury were not demonstrated in the computer-assisted group (compared with 2% in the manual insertion treatment group). The overall surgery-related outcome was satisfactory.
CONCLUSIONS: In contrast to the previously reported computer-assisted technique, our CPS insertion technique provides real-time three-dimensional instrument/screw tip information. This serves as a powerful tool for safe and accurate pedicle screw placement in the cervical spine.

Entities:  

Mesh:

Year:  2003        PMID: 14563142     DOI: 10.3171/spi.2003.99.3.0257

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  72 in total

1.  Cervical pedicle screw insertion using a gutter entry point at the transitional area between the lateral mass and lamina.

Authors:  Katsuhiro Tofuku; Hiroaki Koga; Setsuro Komiya
Journal:  Eur Spine J       Date:  2011-08-10       Impact factor: 3.134

2.  3D-based navigation in posterior stabilisations of the cervical and thoracic spine: problems and benefits. Results of 451 screws.

Authors:  J-S Jarvers; S Katscher; A Franck; S Glasmacher; C Schmidt; T Blattert; C Josten
Journal:  Eur J Trauma Emerg Surg       Date:  2011-04-01       Impact factor: 3.693

3.  Accuracy of biopsy needle navigation using the Medarpa system--computed tomography reality superimposed on the site of intervention.

Authors:  M Fawad Khan; Selami Dogan; Adel Maataoui; Jessen Gurung; Mirko Schiemann; Hanns Ackermann; Stefan Wesarg; Georgios Sakas; Thomas J Vogl
Journal:  Eur Radiol       Date:  2005-03-08       Impact factor: 5.315

4.  Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric data.

Authors:  M Reinhold; F Magerl; M Rieger; M Blauth
Journal:  Eur Spine J       Date:  2006-04-21       Impact factor: 3.134

Review 5.  [Instability of the upper cervical spine due to rheumatism].

Authors:  C E Heyde; U Weber; R Kayser
Journal:  Orthopade       Date:  2006-03       Impact factor: 1.087

6.  Observer reliability in evaluating pedicle screw placement using computed tomography.

Authors:  Victor Kosmopoulos; Nicolas Theumann; Stefano Binaghi; Constantin Schizas
Journal:  Int Orthop       Date:  2006-09-12       Impact factor: 3.075

Review 7.  Comparison of two novel fluoroscopy-based stereotactic methods for cervical pedicle screw placement and review of the literature.

Authors:  M Reinhold; C Bach; L Audigé; R Bale; R Attal; M Blauth; F Magerl
Journal:  Eur Spine J       Date:  2008-01-22       Impact factor: 3.134

8.  Cervical anterior transpedicular screw fixation (ATPS)--Part II. Accuracy of manual insertion and pull-out strength of ATPS.

Authors:  Heiko Koller; Frank Acosta; Mark Tauber; Michael Fox; Hudelmaier Martin; Rosmarie Forstner; Peter Augat; Rainer Penzkofer; Christian Pirich; H Kässmann; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

9.  Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites.

Authors:  Heiko Koller; Axel Hempfing; Frank Acosta; Michael Fox; Armin Scheiter; Mark Tauber; Ulrich Holz; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

10.  Cervical pedicle screw insertion using the technique with direct exposure of the pedicle by laminoforaminotomy.

Authors:  Dae-Jean Jo; Eun-Min Seo; Ki-Tack Kim; Sung-Min Kim; Sang-Hun Lee
Journal:  J Korean Neurosurg Soc       Date:  2012-11-30
View more