PURPOSE: To develop a black blood heart-rate adaptive T2 -prepared balanced steady-state free-precession (BEATS) sequence for myocardial T2 mapping.
METHODS: In BEATS, blood suppression is achieved by using a combination of preexcitation and double inversion recovery pulses. The timing and flip angles of the preexcitation pulse are auto-calculated in each patient based on heart rate. Numerical simulations, phantom studies, and in vivo studies were conducted to evaluate the performance of BEATS. BEATS T2 maps were acquired in 36 patients referred for clinical cardiac MRI and in 1 swine with recent myocardial infarction. Two readers assessed all images acquired in patients to identify the presence of artifacts associated with slow blood flow.
RESULTS: Phantom experiments showed that the BEATS sequence provided accurate T2 values over a wide range of simulated heart rates. Black blood myocardial T2 maps were successfully obtained in all subjects. No significant difference was found between the average T2 measurements obtained from the BEATS and conventional bright-blood T2 ; however, there was a decrease in precision using the BEATS sequence. A suppression of the blood pool resulted in sharper definition of the blood-myocardium border and reduced partial voluming effect. The subjective assessment showed that 16% (18 out of 108) of short-axis slices have residual blood artifacts (12 in the apical slice, 4 in the midventricular slice, and 2 in the basal slice).
CONCLUSION: The BEATS sequence yields dark blood myocardial T2 maps with better definition of the blood-myocardium border. Further studies are warranted to evaluate diagnostic accuracy of black blood T2 mapping.
© 2018 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  black blood; double inversion recovery; myocardial T2 mapping; myocardial edema; partial volume effect

Mesh:

Year:  2018        PMID: 30058162      PMCID: PMC6294305          DOI: 10.1002/mrm.27360

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  43 in total

1.  Visualization and temporal/spatial characterization of cardiac radiofrequency ablation lesions using magnetic resonance imaging.

Authors:  A C Lardo; E R McVeigh; P Jumrussirikul; R D Berger; H Calkins; J Lima; H R Halperin
Journal:  Circulation       Date:  2000-08-08       Impact factor: 29.690

2.  Diffusion-prepared segmented steady-state free precession: Application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls.

Authors:  Ioannis Koktzoglou; Debiao Li
Journal:  J Cardiovasc Magn Reson       Date:  2007       Impact factor: 5.364

3.  Improved suppression of plaque-mimicking artifacts in black-blood carotid atherosclerosis imaging using a multislice motion-sensitized driven-equilibrium (MSDE) turbo spin-echo (TSE) sequence.

Authors:  Jinnan Wang; Vasily L Yarnykh; Thomas Hatsukami; Baocheng Chu; Niranjan Balu; Chun Yuan
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

4.  B1-insensitive T2 preparation for improved coronary magnetic resonance angiography at 3 T.

Authors:  Reza Nezafat; Matthias Stuber; Ronald Ouwerkerk; Ahmed M Gharib; Milind Y Desai; Roderic I Pettigrew
Journal:  Magn Reson Med       Date:  2006-04       Impact factor: 4.668

5.  Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters.

Authors:  Olaf Dietrich; José G Raya; Scott B Reeder; Maximilian F Reiser; Stefan O Schoenberg
Journal:  J Magn Reson Imaging       Date:  2007-08       Impact factor: 4.813

6.  Coronary angiography with magnetization-prepared T2 contrast.

Authors:  J H Brittain; B S Hu; G A Wright; C H Meyer; A Macovski; D G Nishimura
Journal:  Magn Reson Med       Date:  1995-05       Impact factor: 4.668

7.  Cardiac magnetic resonance fluoroscopy.

Authors:  J P Debbins; S J Riederer; P J Rossman; R C Grimm; J P Felmlee; J F Breen; R L Ehman
Journal:  Magn Reson Med       Date:  1996-10       Impact factor: 4.668

8.  Self-navigated isotropic three-dimensional cardiac T2 mapping.

Authors:  Ruud B van Heeswijk; Davide Piccini; Hélène Feliciano; Roger Hullin; Juerg Schwitter; Matthias Stuber
Journal:  Magn Reson Med       Date:  2014-05-08       Impact factor: 4.668

9.  Detection and characterization of acute myocardial infarction in man with use of gated magnetic resonance.

Authors:  M T McNamara; C B Higgins; N Schechtmann; E Botvinick; M J Lipton; K Chatterjee; E G Amparo
Journal:  Circulation       Date:  1985-04       Impact factor: 29.690

10.  Blood correction reduces variability and gender differences in native myocardial T1 values at 1.5 T cardiovascular magnetic resonance - a derivation/validation approach.

Authors:  Jannike Nickander; Magnus Lundin; Goran Abdula; Peder Sörensson; Stefania Rosmini; James C Moon; Peter Kellman; Andreas Sigfridsson; Martin Ugander
Journal:  J Cardiovasc Magn Reson       Date:  2017-04-05       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.