Literature DB >> 16538606

B1-insensitive T2 preparation for improved coronary magnetic resonance angiography at 3 T.

Reza Nezafat1, Matthias Stuber, Ronald Ouwerkerk, Ahmed M Gharib, Milind Y Desai, Roderic I Pettigrew.   

Abstract

At 3 T, the effective wavelength of the RF field is comparable to the dimension of the human body, resulting in B1 standing wave effects and extra variations in phase. This effect is accompanied by an increase in B0 field inhomogeneity compared to 1.5 T. This combination results in nonuniform magnetization preparation by the composite MLEV weighted T2 preparation (T2 Prep) sequence used for coronary magnetic resonance angiography (MRA). A new adiabatic refocusing T2 Prep sequence is presented in which the magnetization is tipped into the transverse plane with a hard RF pulse and refocused using a pair of adiabatic fast-passage RF pulses. The isochromats are subsequently returned to the longitudinal axis using a hard RF pulse. Numerical simulations predict an excellent suppression of artifacts originating from B1 inhomogeneity while achieving good contrast enhancement between coronary arteries and surrounding tissue. This was confirmed by an in vivo study, in which coronary MR angiograms were obtained without a T2 Prep, with an MLEV weighted T2 Prep and the proposed adiabatic T2 Prep. Improved quantitative and qualitative coronary MRA image measurement was achieved using the adiabatic T2 Prep at 3 T. Published 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2006        PMID: 16538606     DOI: 10.1002/mrm.20835

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  56 in total

1.  T₂ -weighted MRI of post-infarct myocardial edema in mice.

Authors:  Ronald J Beyers; R Scott Smith; Yaqin Xu; Bryan A Piras; Michael Salerno; Stuart S Berr; Craig H Meyer; Christopher M Kramer; Brent A French; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2011-05-31       Impact factor: 4.668

2.  Retrograde perfusion and filling of mouse coronary vasculature as preparation for micro computed tomography imaging.

Authors:  Jill J Weyers; Dara D Carlson; Charles E Murry; Stephen M Schwartz; William M Mahoney
Journal:  J Vis Exp       Date:  2012-02-10       Impact factor: 1.355

3.  Noncontrast SSFP pulmonary vein magnetic resonance angiography: impact of off-resonance and flow.

Authors:  Peng Hu; Christian T Stoeck; Jouke Smink; Dana C Peters; Long Ngo; Beth Goddu; Kraig V Kissinger; Lois A Goepfert; Jonathan Chan; Thomas H Hauser; Neil M Rofsky; Warren J Manning; Reza Nezafat
Journal:  J Magn Reson Imaging       Date:  2010-11       Impact factor: 4.813

4.  Coronary MR angiography at 3T during diastole and systole.

Authors:  Ahmed M Gharib; Daniel A Herzka; Ali O Ustun; Milind Y Desai; Julia Locklin; Roderic I Pettigrew; Matthias Stuber
Journal:  J Magn Reson Imaging       Date:  2007-10       Impact factor: 4.813

Review 5.  Cardiac magnetic resonance at high field: promises and problems.

Authors:  Ahmed M Gharib; Abdalla Elagha; Roderic I Pettigrew
Journal:  Curr Probl Diagn Radiol       Date:  2008 Mar-Apr

6.  Evaluation of diffusivity in the anterior lobe of the pituitary gland: 3D turbo field echo with diffusion-sensitized driven-equilibrium preparation.

Authors:  A Hiwatashi; T Yoshiura; O Togao; K Yamashita; K Kikuchi; K Kobayashi; M Ohga; S Sonoda; H Honda; M Obara
Journal:  AJNR Am J Neuroradiol       Date:  2013-07-18       Impact factor: 3.825

7.  3D turbo field echo with diffusion-sensitized driven-equilibrium preparation technique (DSDE-TFE) versus echo planar imaging in evaluation of diffusivity of retinoblastoma.

Authors:  Akio Hiwatashi; Osamu Togao; Koji Yamashita; Kazufumi Kikuchi; Hiroshi Yoshikawa; Makoto Obara; Hiroshi Honda
Journal:  Br J Radiol       Date:  2016-09-16       Impact factor: 3.039

8.  Arterial spin-labeling is useful for the diagnosis of residual or recurrent meningiomas.

Authors:  Kazufumi Kikuchi; Akio Hiwatashi; Osamu Togao; Koji Yamashita; Ryotaro Kamei; Koji Yoshimoto; Koji Iihara; Satoshi O Suzuki; Toru Iwaki; Yuriko Suzuki; Hiroshi Honda
Journal:  Eur Radiol       Date:  2018-04-13       Impact factor: 5.315

9.  Slice-selective adiabatic magnetization T2 -preparation (SAMPA) for efficient T2 -weighted imaging at ultrahigh field strengths.

Authors:  Hadrien Dyvorne; Priti Balchandani
Journal:  Magn Reson Med       Date:  2015-12-01       Impact factor: 4.668

10.  Clinical applications for cardiovascular magnetic resonance imaging at 3 tesla.

Authors:  Allison G Hays; Michael Schär; Sebastian Kelle
Journal:  Curr Cardiol Rev       Date:  2009-08
View more