| Literature DB >> 30034882 |
Bekir Serhat Yildiz1, Gulin Findikoglu2, Yusuf Izzettin Alihanoglu1, Ismail Dogu Kilic1, Harun Evrengul1, Hande Senol3.
Abstract
AIM: This study was designed to assess the effect of patient education on the knowledge of safety and awareness about living with cardiac implantable electronic devices (CIEDs) within the context of phase I cardiac rehabilitation.Entities:
Year: 2018 PMID: 30034882 PMCID: PMC6035822 DOI: 10.1155/2018/5689353
Source DB: PubMed Journal: Rehabil Res Pract ISSN: 2090-2867
Demographic characteristics of the patients with cardiac implantable electronic devices.
|
|
|
|
|---|---|---|
| Age (years) (mean±SD) | 60.54±10.58 | 65.41±14.40 |
| Sex (M/F) | 17/11 (60.7/39.3) | 59/34 (63.4/36.6) |
|
| ||
| Education | ||
| Illiterate | 6 (21.4) | 17 (18.27) |
| Primary & Secondary School | 16 (57.1) | 52 (55.91) |
| High School | 6 (21.4) | 13 (14) |
| University | 0 (0) | 1 (1.1) |
|
| ||
| Occupation | ||
| Retarded | 14 (50) | 48 (51.61) |
| House Wife | 10 (35.7) | 34 (36.55) |
| Self-employed | 3 (10.7) | 8 (8.60) |
| Civil servant & student | 1 (4.6) | 3 (3.22) |
Diagnosis, underlying etiology, type/mode and lifetime of the cardiac implantable electronic device (CIED), and generator replacement number of the patients.
|
|
| |
|---|---|---|
| Diagnosis | ||
| Sinus Node Dysfunction | 8 (28.5) | 31 (33.3) |
| Atrioventricular Node Dysfunction | 11 (39.2) | 37 (39.8) |
| Ventricular Tachycardia/Fibrillation | 6 (21.4) | 10 (10.7 ) |
| Severe Heart Failure | 3 (10.7) | 15 (16.2) |
|
| ||
| Etiology | ||
| Ischemic Heart Disease | 6 (21.4) | 30 (32.2) |
| Post-Myocardial Infarction | 1 (3.6) | 5 (5.3) |
| Cardiomyopathy | 13 (46.4) | 11 (11.8) |
| Degenerative | 2 (7.1) | 28 (30.1) |
| Iatrogenic | - | 3 (3.2) |
| Idiopathic | 6 (21.4) | 16 (17.2) |
|
| ||
| CIED type or mode | ||
| VVI | 1 (3.6) | 12 (12.9) |
| VDDR | 5 (17.9) | 20 (21.5) |
| DDDR | 3 (10.7) | 33 (35.4) |
| ICD (DDD or VVI) | 11 (39.28) | 18 (19.4) |
| ICD-CRT | 8 (28.6) | 10 (10.8) |
|
| ||
| Polarity | ||
| Unipolar | 5 (17.9) | 30 (32.6) |
| Bipolar | 19 (67.9) | 63 (67.7) |
|
| ||
| Utility time of current device (months) | 1.36±0.5 | 55.21±46.8 |
∗According to NASPE/BPEG Generic Pacemaker Code (NBG), 2002.
ICD: implantable cardioverter-defibrillators.
ICD-CRT: implantable cardioverter-defibrillators and cardiac resynchronization therapy.
Correct responses of patients with cardiac implantable electronic devices (CIED) for physical or daily life activities.
|
|
|
|
|
| |
|---|---|---|---|---|---|
|
|
| ||||
| return to their daily life | 13 (46.4) | 22 (78.6) | 81 (87.1) |
| 0.266 |
| drive | 6 (21.4) | 16 (57.1) | 65 (69.9) |
| 0.209 |
| climb the stairs | 11 (39.3) | 26 (92.9) | 78 (83.9) |
| 0.230 |
| use their arm on the side of CIED | 5 (18.5) | 16 (57.1) | 72 (77.4) |
|
|
| do exercise or do sports | 10 (35.7) | 23 (82.1) | 55 (59.1) |
|
|
| swim | 2 (7.1) | 11 (39.3) | 38 (40.9) |
| 0.882 |
| return to their sexual life | 7 (25) | 22 (78.6) | 57 (61.3) |
| 0.092 |
| return to their work | 8 (28.6) | 21 (75) | 71 (76.3) |
| 0.884 |
| bend forward with the trunk | 2 (7.1) | 17 (60.7) | 72 (77.4) |
| 0.079 |
∗p<0.05, for the comparison within the education group.
#p<0.05, for the comparison between groups after education and without education.
Correct responses to questions on safety of household appliances for electromagnetic interference with cardiac implantable electronic devices.
|
|
|
|
|
| |
|---|---|---|---|---|---|
|
|
| ||||
| hair dryers, electrical shavers, electrical knife | 4 (14.3) | 12 (42.9) | 23 (24.7) |
| 0.064 |
| TV, Radio, remote controls | 3 (10.7) | 22 (78.6) | 49 (52.7) |
|
|
| Computers, CD/DVD or music players | 3 (10.7) | 17 (60.7) | 44 (47.3) |
| 0.214 |
| electrical lamps, switch buttons | 6 (21.4) | 23 (82.1) | 46 (49.5) |
|
|
| microwave ovens | 1 (3.6) | 11 (39.3) | 18 (19.4) |
|
|
| magnetic pads, pillows, mattress | 3 (10.7) | 12 (42.9) | 42 (45.2) |
| 0.830 |
| electrical muscles stimulators (such as ab stimulator) | 6 (21.4) | 14 (50) | 41 (44.1) |
| 0.582 |
| treadmills or electrical powered bicycles | 2 (7.1) | 10 (35.7) | 21 (22.6) |
| 0.163 |
| cellular phones | 6 (21.4) | 16 (57.1) | 28 (30.1) |
|
|
| passing through security gates in airports | 28 (100) | 2 (7.1) | 12 (12.9) | - | 0.403 |
∗p<0.05, for the comparison within the education group.
#p<0.05, for the comparison between groups after education and without education.
Correct responses to questions on harmful equipment for electromagnetic interference with cardiac implantable electronic devices.
|
|
|
|
|
| |
|---|---|---|---|---|---|
|
|
| ||||
| power stations, electric generators | 9 (32.1) | 23 (82.1) | 50 (53.8) |
|
|
| chainsaws, welding equipment | 7 (25) | 20 (71.4) | 44 (47.3) |
|
|
| base stations, cell sites | 6 (21.4) | 21 (75) | 58 (62.4) |
| 0.218 |
| amateur/ham radio stations, radiofrequency transmitters, transformers | 8 (28.6) | 17 (60.7) | 53 (57) |
| 0.726 |
| ignition system of automobiles or motor cycles | 7 (25) | 17 (60.7) | 37 (39.8) |
| 0.051 |
| loudspeakers with magnets | 7 (25) | 25 (89.3) | 46 (49.5) |
|
|
∗p<0.05, for the comparison within the education group.
#p<0.05, for the comparison between groups after education and without education.
Correct responses of patients on safety of medical devices for electromagnetic interference with cardiac implantable electronic devices.
|
|
|
|
|
| |
|---|---|---|---|---|---|
|
|
| ||||
| magnetic resonance imaging | 7 (25) | 20 (71.4) | 55 (59.1) |
| 0.240 |
| x-ray | 6 (21.4) | 11 (39.3) | 55 (59.1) | 0.180 | 0.064 |
| ultrasonography | 6 (21.4) | 18 (64.3) | 53 (57) |
| 0.492 |
| computed tomography | 4 (14.3) | 13 (46.4) | 33 (35.5) |
| 0.296 |
| electrocardiographs | 5 (17.9) | 22 (78.6) | 68 (73.1) |
| 0.562 |
| TENS (transcutaneous electrical nerve stimulation) | 0 (0) | 2 (7.1) | 14 (15.1) | - | 0.279 |
| lithotripsy | 2 (7.1) | 8 (28.6) | 22 (23.7) | 0.070 | 0.597 |
| radiotherapy | 2 (7.1) | 8 (28.6) | 22 (23.7) | 0.070 | 0.597 |
| short wave radiofrequency (diathermy) | 0 (0) | 3 (10.7) | 11 (11.8) | - | 0.858 |
| electrical devices of dentist (such as dental drills) | 8 (28.6) | 12 (42.9) | 53 (57) | 0.344 | 0.189 |
| electrocautery | 2 (7.1) | 6 (21.4) | 14 (15.2) | 0.289 | 0.440 |
∗p<0.05, for the comparison within the education group.
#p<0.05, for the comparison between groups after education and without education.