Electromagnetic interference and implanted cardiac devices: the nonmedical environment (part I).

Juna Misiri1, Fred Kusumoto, Nora Goldschlager.   

Abstract

The number of patients with cardiovascular implantable electronic devices (CIEDs), such as permanent pacemakers and implantable cardioverter-defibrillators, is dramatically rising due to an aging population and recent clinical trials showing benefits in mortality and morbidity. Coupled with this increase in the number of patients with CIEDs is the proliferation of technology that emits electromagnetic signals, which can potentially interfere with CIED function through electromagnetic interference (EMI). Despite continuous efforts of manufacturers to create "EMI-proof" CIEDs, adverse events from EMI still occur. Physicians caring for patients with CIEDs should be aware of potential sources of EMI and appropriate management options. This 2-part review aims to provide a contemporary overview of the current knowledge regarding risks attributable to EMI interactions from the most common nonmedical (Part I) and medical (Part II) sources.
© 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22539305      PMCID: PMC6652539          DOI: 10.1002/clc.21998

Source DB:  PubMed          Journal:  Clin Cardiol        ISSN: 0160-9289            Impact factor:   2.882


  11 in total

1.  Forces on cardiac implantable electronic devices during remote magnetic navigation.

Authors:  C Jilek; C Lennerz; B Stracke; H Badran; V Semmler; T Reents; S Ammar; S Fichtner; B Haller; G Hessling; I Deisenhofer; C Kolb
Journal:  Clin Res Cardiol       Date:  2012-09-29       Impact factor: 5.460

2.  Correlation of geomagnetic activity with implantable cardioverter defibrillator shocks and antitachycardia pacing.

Authors:  Elisa Ebrille; Tomas Konecny; Dana Konecny; Radim Spacek; Paul Jones; Pavel Ambroz; Christopher V DeSimone; Brian D Powell; David L Hayes; Paul A Friedman; Samuel J Asirvatham
Journal:  Mayo Clin Proc       Date:  2015-02       Impact factor: 7.616

3.  Electromagnetic interference in implantable cardioverter defibrillators: present but rare.

Authors:  Gesa von Olshausen; Ina-Christine Rondak; Carsten Lennerz; Verena Semmler; Christian Grebmer; Tilko Reents; Sonia Ammar-Busch; Alessandra Buiatti; Felix Bourier; Isabel Deisenhofer; Christof Kolb
Journal:  Clin Res Cardiol       Date:  2016-01-29       Impact factor: 5.460

4.  Electromagnetic Interference in a Private Swimming Pool: Case report.

Authors:  Sandia Iskandar; Madhav Lavu; Moustapha Atoui; Dhanunjaya Lakkireddy
Journal:  Indian Pacing Electrophysiol J       Date:  2016-02-12

5.  Personal medical electronic devices and walk-through metal detector security systems: assessing electromagnetic interference effects.

Authors:  Joshua Guag; Bisrat Addissie; Donald Witters
Journal:  Biomed Eng Online       Date:  2017-03-20       Impact factor: 2.819

Review 6.  Interference by Modern Smartphones and Accessories with Cardiac Pacemakers and Defibrillators.

Authors:  Fahd Nadeem; Cao Thach Tran; Estelle Torbey; Daniel Philbin; Carlos Morales; Michael Wu
Journal:  Curr Cardiol Rep       Date:  2022-01-27       Impact factor: 2.931

7.  iPad2(R) use in patients with implantable cardioverter defibrillators causes electromagnetic interference: the EMIT Study.

Authors:  Teri M Kozik; Gianna Chien; Therese F Connolly; Gurinder S Grewal; David Liang; Walter Chien
Journal:  J Am Heart Assoc       Date:  2014-04-10       Impact factor: 5.501

8.  Cardiac Implantable Electronic Device Safety during Magnetic Resonance Imaging.

Authors:  You Mi Hwang; Jun Kim; Ji Hyun Lee; Minsu Kim; Gi-Byoung Nam; Kee-Joon Choi; You-Ho Kim
Journal:  Korean Circ J       Date:  2016-11-01       Impact factor: 3.243

9.  How Do Patients Understand Safety for Cardiac Implantable Devices? Importance of Postintervention Education.

Authors:  Bekir Serhat Yildiz; Gulin Findikoglu; Yusuf Izzettin Alihanoglu; Ismail Dogu Kilic; Harun Evrengul; Hande Senol
Journal:  Rehabil Res Pract       Date:  2018-06-24

10.  Electromagnetic interference in cardiac electronic implants caused by novel electrical appliances emitting electromagnetic fields in the intermediate frequency range: a systematic review.

Authors:  Sarah Driessen; Andreas Napp; Kristina Schmiedchen; Thomas Kraus; Dominik Stunder
Journal:  Europace       Date:  2019-02-01       Impact factor: 5.214

View more