A Monte Carlo Model of a Benchtop X-Ray Fluorescence Computed Tomography System and Its Application to Validate a Deconvolution-Based X-Ray Fluorescence Signal Extraction Method.

Md Foiez Ahmed, Selcuk Yasar, Sang Hyun Cho.   

Abstract

In this study, we developed and validated a Geant4-based Monte Carlo (MC) model of an experimental benchtop X-ray fluorescence (XRF) computed tomography (XFCT) system for quantitative imaging of metallic nanoparticles such as gold nanoparticles (GNPs) injected into small animals for preclinical testing of various NP-based diagnostic and therapeutic approaches. Detailed hardware components of the current benchtop XFCT system, including the X-ray source, excitation beam collimation and filtration, custom imaging phantoms with GNP solutions, and single/ring/linear array detectors with custom collimation, were incorporated into the MC model. In conjunction with a known CdTe detector response function, a deconvolution-based XRF signal extraction method was also developed in this study, which enabled complete separation of gold K-shell XRF peaks even when they almost overlapped and facilitated extraction of XRF signals from a broadband Compton scattered photon background. The extracted signal-to-background ratios were comparable with those expected using an ideal detector with high enough energy resolution (e.g., 0.1 keV full-width at half-maximum). Once convoluted with the CdTe detector response function, the MC-calculated spectra for excitation beams or emitted photons and XFCT image spatial resolutions agreed well with those measured experimentally. Thus, the current MC model can be used to optimize the beam/imaging parameters (e.g., beam geometry, excitation X-ray beam energy, and X-ray filter material) as well as the design of critical hardware components (e.g., detector collimators) within the current benchtop XFCT system. Also, the current XRF signal extraction method can relax the usual stringent requirement of detector energy resolution while not degrading the sensitivity of benchtop XFCT.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29994762      PMCID: PMC6257945          DOI: 10.1109/TMI.2018.2836973

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  20 in total

1.  Estimation of tumour dose enhancement due to gold nanoparticles during typical radiation treatments: a preliminary Monte Carlo study.

Authors:  Sang Hyun Cho
Journal:  Phys Med Biol       Date:  2005-07-13       Impact factor: 3.609

2.  Improved signal-to-noise ratio for non-perpendicular detection angles in x-ray fluorescence computed tomography (XFCT).

Authors:  Martin Sjölin; Mats Danielsson
Journal:  Phys Med Biol       Date:  2014-10-13       Impact factor: 3.609

3.  Spectrum reconstruction method based on the detector response model calibrated by x-ray fluorescence.

Authors:  Ruizhe Li; Liang Li; Zhiqiang Chen
Journal:  Phys Med Biol       Date:  2017-01-12       Impact factor: 3.609

4.  Feasibility study of Compton cameras for x-ray fluorescence computed tomography with humans.

Authors:  Don Vernekohl; Moiz Ahmad; Garry Chinn; Lei Xing
Journal:  Phys Med Biol       Date:  2016-11-15       Impact factor: 3.609

5.  Trace element analysis in biological samples by using XRF spectrometry with secondary radiation.

Authors:  R Cesareo; G Viezzoli
Journal:  Phys Med Biol       Date:  1983-11       Impact factor: 3.609

6.  X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects using 110 kVp x-rays.

Authors:  Seong-Kyun Cheong; Bernard L Jones; Arsalan K Siddiqi; Fang Liu; Nivedh Manohar; Sang Hyun Cho
Journal:  Phys Med Biol       Date:  2010-01-13       Impact factor: 3.609

7.  Experimental demonstration of benchtop x-ray fluorescence computed tomography (XFCT) of gold nanoparticle-loaded objects using lead- and tin-filtered polychromatic cone-beams.

Authors:  Bernard L Jones; Nivedh Manohar; Francisco Reynoso; Andrew Karellas; Sang Hyun Cho
Journal:  Phys Med Biol       Date:  2012-11-08       Impact factor: 3.609

8.  Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications.

Authors:  Stefano Del Sordo; Leonardo Abbene; Ezio Caroli; Anna Maria Mancini; Andrea Zappettini; Pietro Ubertini
Journal:  Sensors (Basel)       Date:  2009-05-12       Impact factor: 3.576

9.  Quantitative imaging of gold nanoparticle distribution in a tumor-bearing mouse using benchtop x-ray fluorescence computed tomography.

Authors:  Nivedh Manohar; Francisco J Reynoso; Parmeswaran Diagaradjane; Sunil Krishnan; Sang Hyun Cho
Journal:  Sci Rep       Date:  2016-02-25       Impact factor: 4.379

10.  Pinhole X-ray fluorescence imaging of gadolinium and gold nanoparticles using polychromatic X-rays: a Monte Carlo study.

Authors:  Seongmoon Jung; Wonmo Sung; Sung-Joon Ye
Journal:  Int J Nanomedicine       Date:  2017-08-11
View more
  6 in total

1.  Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging.

Authors:  Sandun Jayarathna; Md Foiez Ahmed; Liam O'Ryan; Hem Moktan; Yonggang Cui; Sang Hyun Cho
Journal:  IEEE Access       Date:  2021-03-29       Impact factor: 3.367

2.  Investigation of transmission computed tomography (CT) image quality and x-ray dose achievable from an experimental dual-mode benchtop x-ray fluorescence CT and transmission CT system.

Authors:  Luzhen Deng; Selcuk Yasar; Md Foiez Ahmed; Sandun Jayarathna; Peng Feng; Biao Wei; Srinivasan Vedantham; Andrew Karellas; Sang Hyun Cho
Journal:  J Xray Sci Technol       Date:  2019       Impact factor: 1.535

3.  Sensitivity enhancement of an experimental benchtop x-ray fluorescence imaging system by deploying a single crystal cadmium telluride detector system optimized for high flux x-ray operations.

Authors:  Hem Moktan; Sandun Jayarathna; Sang Hyun Cho
Journal:  Nucl Instrum Methods Phys Res A       Date:  2021-12-13       Impact factor: 1.455

4.  Development of an attenuation correction method for direct x-ray fluorescence (XRF) imaging utilizing gold L-shell XRF photons.

Authors:  Md Foiez Ahmed; Selcuk Yasar; Sang Hyun Cho
Journal:  Med Phys       Date:  2018-11-08       Impact factor: 4.071

5.  Bias-voltage dependent operational characteristics of a fully spectroscopic pixelated cadmium telluride detector system within an experimental benchtop x-ray fluorescence imaging setup.

Authors:  Hem Moktan; Raj Kumar Panta; Sang Hyun Cho
Journal:  Biomed Phys Eng Express       Date:  2021-12-07

6.  A Geant4-based Monte Carlo study of a benchtop multi-pinhole X-ray fluorescence computed tomography imaging.

Authors:  Luzhen Deng; Biao Wei; Peng He; Yi Zhang; Peng Feng
Journal:  Int J Nanomedicine       Date:  2018-11-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.